Visual detection of thrombin using a strip biosensor through aptamer-cleavage reaction with enzyme catalytic amplification
- 24 September 2015
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 140 (22) , 7710-7717
Abstract
A new class of strip biosensors has been established based on well-distributed thrombin aptamer-linked gold nanoparticle aggregates, which will undergo a cracking reaction when the target recognizes its homologous aptamer. Combining the aptamer-cleavage reaction with the enzyme catalytic amplification system, our proposed lateral flow strip biosensor (LFB) is capable of visually detecting 6.4 pM of thrombin without instrumentation within 12 minutes. Under the optimal conditions, the quantitative detection of thrombin by a portable strip reader exhibited a linear relationship between the peak area and the concentration of thrombin in the range of 6.4 pM–500 nM with a detection limit of 4.9 pM, which is three orders of magnitude lower than that of the aptamer-functionalized gold nanoparticle-based LFB (2.5 nM, Xu et al., Anal. Chem., 2009, 81, 669–675). As the aptamers have no special requirements and the gold nanoparticles can also be replaced by other metallic nanoparticles, this method for strip sensing is expected to be generally applicable in point of care testing, home testing, medical diagnostics, clinical diagnosis, and environmental monitoring.Keywords
This publication has 55 references indexed in Scilit:
- Visual detection of single-base mismatches in DNA using hairpin oligonucleotide with double-target DNA binding sequences and gold nanoparticlesBiosensors and Bioelectronics, 2012
- Visual detection of gene mutations based on isothermal strand-displacement polymerase reaction and lateral flow stripBiosensors and Bioelectronics, 2012
- Aptamer-Conjugated Nanoparticles for Cancer Cell DetectionAnalytical Chemistry, 2011
- Ultrasensitive nucleic acid biosensor based on enzyme–gold nanoparticle dual label and lateral flow strip biosensorBiosensors and Bioelectronics, 2011
- Control of DNA Strand Displacement Kinetics Using Toehold ExchangeJournal of the American Chemical Society, 2009
- Quantitative Immunochromatographic Strip Biosensor for the Detection of Carcinoembryonic Antigen Tumor Biomarker in Human PlasmaAmerican Journal of Biomedical Sciences, 2009
- Metal-Dependent Global Folding and Activity of the 8-17 DNAzyme Studied by Fluorescence Resonance Energy TransferJournal of the American Chemical Society, 2007
- Aptamer-Directed Self-Assembly of Protein Arrays on a DNA NanostructureAngewandte Chemie, 2005
- Nanostructures in BiodiagnosticsChemical Reviews, 2005
- Systematic Evolution of Ligands by Exponential Enrichment: RNA Ligands to Bacteriophage T4 DNA PolymeraseScience, 1990