Titanium-Nitride-Oxide–Coated vs Everolimus-Eluting Stents in Acute Coronary Syndrome
Open Access
- 1 July 2023
- journal article
- research article
- Published by American Medical Association (AMA) in JAMA Cardiology
- Vol. 8 (7) , 703-708
Abstract
Importance: Titanium-nitride-oxide (TiNO)–coated stents show faster strut coverage compared with drug-eluting stents without excessive intimal-hyperplasia observed in bare metal stents. It is important to study long-term clinical outcomes after treatment of patients with an acute coronary syndrome (ACS) by TiNO-coated stents, which are neither drug-eluting stents nor bare metal stents.Objective: To compare the rate of main composite outcome of cardiac death, myocardial infarction (MI), or ischemia-driven target lesion revascularization at 5 years in patients with ACS randomized to receive either a TiNO-coated stent or a third-generation everolimus-eluting stent (EES).Design, Setting, and Participants: This multicenter, randomized, controlled, open-label trial was conducted in 12 clinical sites in 5 European countries and enrolled patients from January 2014 to August 2016. Patients presenting with ACS (ST-segment elevation MI, non–ST-segment elevation MI, and unstable angina) with at least 1 de novo lesion were randomized to receive either a TiNO-coated stent or an EES. The present report analyzes the long-term follow-up for the main composite outcome and its individual components. Analysis took place between November 2022 to March 2023.Main outcome: The primary end point was a composite of cardiac death, MI, or target lesion revascularization at 12-month follow-up.Results: A total of 1491 patients with ACS were randomly assigned to receive either TiNO-coated stents (989 [66.3%]) or EES (502 [33.7%]). The mean (SD) age was 62.7 (10.8) years, and 363 (24.3%) were female. At 5 years, the main composite outcome events occurred in 111 patients (11.2%) in the TiNO group vs 60 patients (12%) in the EES group (hazard ratio [HR], 0.94; 95% CI, 0.69-1.28; P = .69). The rate of cardiac death was 0.9% (9 of 989) vs 3.0% (15 of 502) (HR, 0.30; 95% CI, 0.13-0.69; P = .005), the rate of MI was 4.6% (45 of 989) vs 7.0% (35 of 502) (HR, 0.64; 95% CI, 0.41-0.99; P = .049), the rate of stent thrombosis was 1.2% (12 of 989) vs 2.8% (14 of 502) (HR, 0.43; 95% CI, 0.20-0.93; P = .034), and the rate of target lesion revascularization was 7.4% (73 of 989) vs 6.4% (32 of 502) (HR, 1.16; 95% CI, 0.77-1.76; P = .47) in the TiNO-coated stent arm and in the EES arm, respectively.Conclusion and relevance: In this study, patients with ACS had a main composite outcome that was not different 5 years after TiNO-coated stent or EES.Trial Registration: ClinicalTrials.gov Identifier: NCT02049229Keywords
This publication has 14 references indexed in Scilit:
- Titanium-Nitride-Oxide–Coated Versus Everolimus-Eluting Stents in Acute Coronary SyndromeJACC: Cardiovascular Interventions, 2020
- Long-term clinical outcome of titanium-nitride-oxide-coated stents versus everolimus-eluting stents in acute coronary syndrome: Final report of the BASE ACS trialInternational Journal of Cardiology, 2016
- Clinical outcomes in patients with ST-segment elevation myocardial infarction treated with everolimus-eluting stents versus bare-metal stents (EXAMINATION): 5-year results of a randomised trialThe Lancet, 2016
- TIDES-ACS Trial: comparison of titanium-nitride-oxide coated bio-active-stent to the drug (everolimus)-eluting stent in acute coronary syndrome. Study design and objectives.2015
- Clinical Outcomes With Bioabsorbable Polymer- Versus Durable Polymer-Based Drug-Eluting and Bare-Metal StentsJACC, 2014
- Five-year clinical outcome of titanium-nitride-oxide-coated bioactive stents versus paclitaxel-eluting stents in patients with acute myocardial infarction: Long-term follow-up from the TITAX AMI trialInternational Journal of Cardiology, 2013
- A prospective randomised comparison of titanium-nitride-oxide-coated bioactive stents with everolimus-eluting stents in acute coronary syndrome: the BASE-ACS trialEuroIntervention, 2012
- Delayed Arterial Healing and Increased Late Stent Thrombosis at Culprit Sites After Drug-Eluting Stent Placement for Acute Myocardial Infarction PatientsCirculation, 2008
- Meta-analysis of randomized trials on drug-eluting stents vs. bare-metal stents in patients with acute myocardial infarctionEuropean Heart Journal, 2007
- Randomized Comparison of a Titanium-Nitride-Oxide–Coated Stent With a Stainless Steel Stent for Coronary RevascularizationCirculation, 2005