Pasi Paavo Karjalainen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Pasi Paavo Karjalainen has a total of 90 co-authors. Here are the top co-authors by number of shared publications:
- Frederic Christopher Daoud
INSERM, BPH, U1219, Université de Bordeaux, 33000 Bordeaux, France
5 shared publications - Bogdan Catargi
Endocrinology-Metabolic Diseases, Hôpital Saint-André, Bordeaux University, 33000 Bordeaux, France
3 shared publications - Edouard Gerbaud
Cardiology Intensive Care Unit and Interventional Cardiology, Hôpital Cardiologique du Haut-Lévêque, Pessac, France
3 shared publications - Andreas Rück
Karolinska University Hospital
2 shared publications - Ashkan Eftekhari
Department of Cardiology, Aalborg University Hospital, Aalborg, Denmark
2 shared publications - Charlotte Glinge
Department of Cardiology, Rigshospitalet, Copenhagen University Hospital, Copenhagen, Denmark
2 shared publications
Latest Publications
- 1 September 2026
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Interventions
- Vol. 19 (9)
Impact of Coronary Diameter Stenosis and Proximal Lesion Location on Outcomes Following PCI in Patients Undergoing TAVI: Prespecified NOTION-3 Substudy
BACKGROUND: Optimal treatment of coronary artery disease in patients undergoing transcatheter aortic valve implantation remains debated. Here, our aim was to analyze the impact of the diameter and location of coronary stenosis on outcomes in patients undergoing percutaneous coronary intervention (PCI) with transcatheter aortic valve implantation. METHODS: This study was a prespecified subanalysis of the NOTION-3 trial (Nordic Aortic Valve Intervention), which randomized patients with severe symptomatic aortic stenosis and physiologically significant stable coronary artery disease to receive either PCI or conservative treatment of coronary artery disease with transcatheter aortic valve implantation. In this substudy, patients were stratified according to diameter stenosis (P for interaction=0.051). PCI reduced major adverse cardiovascular events in case of proximal stenosis (26% versus 38%; hazard ratio, 0.61 [95% CI, 0.40–0.93]), although the difference in effect remained nonsignificant when compared with patients with nonproximal stenosis (28% versus 32%; hazard ratio, 0.91 [95% CI, 0.52–1.61]; P for interaction=0.27). CONCLUSIONS: The beneficial effect of PCI in patients undergoing transcatheter aortic valve implantation with physiologically significant stable coronary artery disease was seemingly pronounced in patients with high-grade stenosis, while stenosis location was not found to modify the outcome despite an almost similar beneficial effect with PCI in patients with proximal stenosis.
- 1 September 2026
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Interventions
- Vol. 19 (9)
Impact of Coronary Diameter Stenosis and Proximal Lesion Location on Outcomes Following PCI in Patients Undergoing TAVI: Prespecified NOTION-3 Substudy
BACKGROUND: Optimal treatment of coronary artery disease in patients undergoing transcatheter aortic valve implantation remains debated. Here, our aim was to analyze the impact of the diameter and location of coronary stenosis on outcomes in patients undergoing percutaneous coronary intervention (PCI) with transcatheter aortic valve implantation. METHODS: This study was a prespecified subanalysis of the NOTION-3 trial (Nordic Aortic Valve Intervention), which randomized patients with severe symptomatic aortic stenosis and physiologically significant stable coronary artery disease to receive either PCI or conservative treatment of coronary artery disease with transcatheter aortic valve implantation. In this substudy, patients were stratified according to diameter stenosis (P for interaction=0.051). PCI reduced major adverse cardiovascular events in case of proximal stenosis (26% versus 38%; hazard ratio, 0.61 [95% CI, 0.40–0.93]), although the difference in effect remained nonsignificant when compared with patients with nonproximal stenosis (28% versus 32%; hazard ratio, 0.91 [95% CI, 0.52–1.61]; P for interaction=0.27). CONCLUSIONS: The beneficial effect of PCI in patients undergoing transcatheter aortic valve implantation with physiologically significant stable coronary artery disease was seemingly pronounced in patients with high-grade stenosis, while stenosis location was not found to modify the outcome despite an almost similar beneficial effect with PCI in patients with proximal stenosis.
- 26 May 2026
- Published by Wolters Kluwer Health in Circulation
- Vol. 153 (21) , 1687-1690
Impact of Angina on Outcome After Percutaneous Coronary Intervention in Patients Undergoing Transcatheter Aortic Valve Implantation: Insights From the NOTION-3 Trial
- 26 May 2026
- Published by Wolters Kluwer Health in Circulation
- Vol. 153 (21) , 1687-1690
Impact of Angina on Outcome After Percutaneous Coronary Intervention in Patients Undergoing Transcatheter Aortic Valve Implantation: Insights From the NOTION-3 Trial
- Open Access
- 6 November 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (21) , 6952
Five-Year Efficacy and Safety of TiNO-Coated Stents Versus Drug-Eluting Stents in Acute Coronary Syndrome: A Meta-Analysis
(1) Background: Percutaneous coronary interventions (PCI) in patients with acute coronary syndrome (ACS) are performed with titanium-nitride-oxide-coated stents (TiNOSs) or drug-eluting stents (DESs). The initial completion of this prospective systematic literature review (SLR) of prospective randomized controlled trials (RCTs) showed that TiNOSs are non-inferior to DESs in major adverse cardiac event (MACE) rates and present a lower risk of recurrent myocardial infarction (MI) at 1-year follow-up. This iteration of the SLR protocol performs the critical assessment of 5-year follow-up outcomes with clinical validity and generalizability assessments. (2) Methods: The previously described SLR and meta-analysis protocol, per PRISMA, Cochrane methods, and GRADE, was applied to 5-year follow-up outcomes. (3) Results: Three RCTs were eligible, comprising 1620 patients with TiNOS vs. 1123 with DES. The pooled risk ratios (RRs) and 95% confidence intervals were MACE 0.82 [0.68, 0.99], MI 0.58 [0.44, 0.78], cardiac death (CD) 0.46 [0.28, 0.76], ischemia-driven target lesion revascularization (TLR) 1.03 [0.79, 1.33], probable or definite stent thrombosis (ST) 0.32 [0.21, 0.59], and all-cause mortality (TD) 0.84 [0.63, 1.12]. The evidence certainty was high in MACE, CD, MI, and ST, and moderate in TLR and TD. (4) Conclusions: TiNOSs in ACS at 5-year follow-up appear safer than DESs and equally efficacious. The pooled RRs stratified by clinical presentation and stent type will be required to test this meta-analysis’s clinical validity and generalize its results to patient populations with varying proportions of clinical presentations and DES options.
- 6 November 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (21) , 6952
Open AccessFive-Year Efficacy and Safety of TiNO-Coated Stents Versus Drug-Eluting Stents in Acute Coronary Syndrome: A Meta-Analysis
(1) Background: Percutaneous coronary interventions (PCI) in patients with acute coronary syndrome (ACS) are performed with titanium-nitride-oxide-coated stents (TiNOSs) or drug-eluting stents (DESs). The initial completion of this prospective systematic literature review (SLR) of prospective randomized controlled trials (RCTs) showed that TiNOSs are non-inferior to DESs in major adverse cardiac event (MACE) rates and present a lower risk of recurrent myocardial infarction (MI) at 1-year follow-up. This iteration of the SLR protocol performs the critical assessment of 5-year follow-up outcomes with clinical validity and generalizability assessments. (2) Methods: The previously described SLR and meta-analysis protocol, per PRISMA, Cochrane methods, and GRADE, was applied to 5-year follow-up outcomes. (3) Results: Three RCTs were eligible, comprising 1620 patients with TiNOS vs. 1123 with DES. The pooled risk ratios (RRs) and 95% confidence intervals were MACE 0.82 [0.68, 0.99], MI 0.58 [0.44, 0.78], cardiac death (CD) 0.46 [0.28, 0.76], ischemia-driven target lesion revascularization (TLR) 1.03 [0.79, 1.33], probable or definite stent thrombosis (ST) 0.32 [0.21, 0.59], and all-cause mortality (TD) 0.84 [0.63, 1.12]. The evidence certainty was high in MACE, CD, MI, and ST, and moderate in TLR and TD. (4) Conclusions: TiNOSs in ACS at 5-year follow-up appear safer than DESs and equally efficacious. The pooled RRs stratified by clinical presentation and stent type will be required to test this meta-analysis’s clinical validity and generalize its results to patient populations with varying proportions of clinical presentations and DES options.
- Open Access
Five-year Efficacy and Safety of TiNO-Coated Stents Versus Drug-Eluting Stents in Acute Coronary Syndrome. A meta-analysis
(1) Background: Percutaneous Coronary Interventions (PCI) in patients with acute coronary syndrome (ACS) are performed with titanium-nitride-oxide-coated stents (TiNOS) or drug-eluting stents (DES). This prospective systematic literature review (SLR) of prospective, randomized, controlled trials (RCTs) showed TiNOS is non-inferior to DES in major adverse cardiac events (MACE) rates and presents a lower risk of recurrent myocardial infarction (MI) at 1-year follow-up. (2) Methods: The previously described SLR and meta-analysis protocol, per PRISMA, Cochrane methods, and GRADE, applied here to 5-year follow-up outcomes. (3) Results: Three RCTs were eligible, comprising 1,620 patients with TiNOS vs. 1,123 with DES. The pooled risk ratios (RRs) and 95% confidence intervals were: MACE 0.82 [0.68, 0.99], MI 0.58 [0.44, 0.78], cardiac death (CD) 0.46 [0.28, 0.76], ischemia-driven target lesion re-vascularization (TLR) 1.03 [0.79, 1.33], probable or definite stent thrombosis (ST) 0.32 [0.21, 0.59], and all-cause mortality (TD) 0.84 [0.63, 1.12]. Evidence certainty was high in MACE, CD, MI, and ST. Certainty was moderate in TLR and TD. (4) Conclusions: TiNOS in ACS at 5-year follow-up appears safer than DES and equally efficacious. Stratified pooled outcomes by clinical presentation would facilitate clinical validity benchmarking and generalization to target populations.
Open AccessFive-year Efficacy and Safety of TiNO-Coated Stents Versus Drug-Eluting Stents in Acute Coronary Syndrome. A meta-analysis
(1) Background: Percutaneous Coronary Interventions (PCI) in patients with acute coronary syndrome (ACS) are performed with titanium-nitride-oxide-coated stents (TiNOS) or drug-eluting stents (DES). This prospective systematic literature review (SLR) of prospective, randomized, controlled trials (RCTs) showed TiNOS is non-inferior to DES in major adverse cardiac events (MACE) rates and presents a lower risk of recurrent myocardial infarction (MI) at 1-year follow-up. (2) Methods: The previously described SLR and meta-analysis protocol, per PRISMA, Cochrane methods, and GRADE, applied here to 5-year follow-up outcomes. (3) Results: Three RCTs were eligible, comprising 1,620 patients with TiNOS vs. 1,123 with DES. The pooled risk ratios (RRs) and 95% confidence intervals were: MACE 0.82 [0.68, 0.99], MI 0.58 [0.44, 0.78], cardiac death (CD) 0.46 [0.28, 0.76], ischemia-driven target lesion re-vascularization (TLR) 1.03 [0.79, 1.33], probable or definite stent thrombosis (ST) 0.32 [0.21, 0.59], and all-cause mortality (TD) 0.84 [0.63, 1.12]. Evidence certainty was high in MACE, CD, MI, and ST. Certainty was moderate in TLR and TD. (4) Conclusions: TiNOS in ACS at 5-year follow-up appears safer than DES and equally efficacious. Stratified pooled outcomes by clinical presentation would facilitate clinical validity benchmarking and generalization to target populations.
- Open Access
- 20 August 2023
- Published by ScienceOpen in ScienceOpen Preprints
Five-year Efficacy and Safety of TiNO-Coated Stents Versus Drug-Eluting Stents in Acute Coronary Syndrome. A meta-analysis.
(1) Background: The initial phase of this prospective systematic literature review (SLR) showed that short-term 1-year outcomes with non-drug-eluting titanium-nitride-oxide-coated stents (TiNOS) in acute coronary syndrome (ACS) are non-inferior to drug-eluting stents (DES) in terms of device-oriented composite Major Adverse Cardiac Events (MACE) and safer than DES in terms of recurrent myocardial infarction (MI). This second phase of the SLR assesses long-term 5-year outcomes. (2) Methods: The SLR protocol (PROSPERO CRD4201809062) was conducted per PRISMA guidelines. Prospective, randomized, controlled trials (RCTs) comparing MACE and its components after 5-year follow-up post-PCI with TiNOS vs. DES were searched. Each endpoint's pooled risk ratio (RR) was computed and stratified in RCTs with ACS only vs. RCTs with chronic coronary syndrome (CCS) or ACS. (3) Results: Four RCTs were eligible, comprising 1,772 patients with TiNOS vs. 1,273 with DES. Three RCTs reported outcomes in ACS only (1,630 vs. 1,123 pa-tients). Pooled RRs in the ACS-only RCTs were: MACE 0.82 [0.68, 0.99], MI 0.58 [0.44, 0.78], cardiac death (CD) 0.46 [0.28, 0.76], ischemia-driven target lesion revascularization (TLR) 1.03 [0.79, 1.33], probable or definite stent thrombosis (ST) 0.32 [0.21, 0.59], and total death (TD) 0.84 [0.63, 1.12]. Evidence certainty was high and robust to sensitivity analysis in MACE, MI, and ST, moderate and not robust in CD, TLR, and TD. The clinical validation and generalization would require stratifying the pooled RRs by clinical presentation. (4) Conclusions: TiNOS efficacy appears safer than DES in CD, MI, and ST and is similarly efficacious in TLR, and MACE, with a similar TD rate, in ACS at 5-year follow-up.
- 20 August 2023
- Published by ScienceOpen in ScienceOpen Preprints
Open AccessFive-year Efficacy and Safety of TiNO-Coated Stents Versus Drug-Eluting Stents in Acute Coronary Syndrome. A meta-analysis.
(1) Background: The initial phase of this prospective systematic literature review (SLR) showed that short-term 1-year outcomes with non-drug-eluting titanium-nitride-oxide-coated stents (TiNOS) in acute coronary syndrome (ACS) are non-inferior to drug-eluting stents (DES) in terms of device-oriented composite Major Adverse Cardiac Events (MACE) and safer than DES in terms of recurrent myocardial infarction (MI). This second phase of the SLR assesses long-term 5-year outcomes. (2) Methods: The SLR protocol (PROSPERO CRD4201809062) was conducted per PRISMA guidelines. Prospective, randomized, controlled trials (RCTs) comparing MACE and its components after 5-year follow-up post-PCI with TiNOS vs. DES were searched. Each endpoint's pooled risk ratio (RR) was computed and stratified in RCTs with ACS only vs. RCTs with chronic coronary syndrome (CCS) or ACS. (3) Results: Four RCTs were eligible, comprising 1,772 patients with TiNOS vs. 1,273 with DES. Three RCTs reported outcomes in ACS only (1,630 vs. 1,123 pa-tients). Pooled RRs in the ACS-only RCTs were: MACE 0.82 [0.68, 0.99], MI 0.58 [0.44, 0.78], cardiac death (CD) 0.46 [0.28, 0.76], ischemia-driven target lesion revascularization (TLR) 1.03 [0.79, 1.33], probable or definite stent thrombosis (ST) 0.32 [0.21, 0.59], and total death (TD) 0.84 [0.63, 1.12]. Evidence certainty was high and robust to sensitivity analysis in MACE, MI, and ST, moderate and not robust in CD, TLR, and TD. The clinical validation and generalization would require stratifying the pooled RRs by clinical presentation. (4) Conclusions: TiNOS efficacy appears safer than DES in CD, MI, and ST and is similarly efficacious in TLR, and MACE, with a similar TD rate, in ACS at 5-year follow-up.
- Open Access
- 1 July 2023
- Published by American Medical Association (AMA) in JAMA Cardiology
- Vol. 8 (7) , 703-708
Titanium-Nitride-Oxide–Coated vs Everolimus-Eluting Stents in Acute Coronary Syndrome
Importance: Titanium-nitride-oxide (TiNO)–coated stents show faster strut coverage compared with drug-eluting stents without excessive intimal-hyperplasia observed in bare metal stents. It is important to study long-term clinical outcomes after treatment of patients with an acute coronary syndrome (ACS) by TiNO-coated stents, which are neither drug-eluting stents nor bare metal stents.Objective: To compare the rate of main composite outcome of cardiac death, myocardial infarction (MI), or ischemia-driven target lesion revascularization at 5 years in patients with ACS randomized to receive either a TiNO-coated stent or a third-generation everolimus-eluting stent (EES).Design, Setting, and Participants: This multicenter, randomized, controlled, open-label trial was conducted in 12 clinical sites in 5 European countries and enrolled patients from January 2014 to August 2016. Patients presenting with ACS (ST-segment elevation MI, non–ST-segment elevation MI, and unstable angina) with at least 1 de novo lesion were randomized to receive either a TiNO-coated stent or an EES. The present report analyzes the long-term follow-up for the main composite outcome and its individual components. Analysis took place between November 2022 to March 2023.Main outcome: The primary end point was a composite of cardiac death, MI, or target lesion revascularization at 12-month follow-up.Results: A total of 1491 patients with ACS were randomly assigned to receive either TiNO-coated stents (989 [66.3%]) or EES (502 [33.7%]). The mean (SD) age was 62.7 (10.8) years, and 363 (24.3%) were female. At 5 years, the main composite outcome events occurred in 111 patients (11.2%) in the TiNO group vs 60 patients (12%) in the EES group (hazard ratio [HR], 0.94; 95% CI, 0.69-1.28; P = .69). The rate of cardiac death was 0.9% (9 of 989) vs 3.0% (15 of 502) (HR, 0.30; 95% CI, 0.13-0.69; P = .005), the rate of MI was 4.6% (45 of 989) vs 7.0% (35 of 502) (HR, 0.64; 95% CI, 0.41-0.99; P = .049), the rate of stent thrombosis was 1.2% (12 of 989) vs 2.8% (14 of 502) (HR, 0.43; 95% CI, 0.20-0.93; P = .034), and the rate of target lesion revascularization was 7.4% (73 of 989) vs 6.4% (32 of 502) (HR, 1.16; 95% CI, 0.77-1.76; P = .47) in the TiNO-coated stent arm and in the EES arm, respectively.Conclusion and relevance: In this study, patients with ACS had a main composite outcome that was not different 5 years after TiNO-coated stent or EES.Trial Registration: ClinicalTrials.gov Identifier: NCT02049229
- 1 July 2023
- Published by American Medical Association (AMA) in JAMA Cardiology
- Vol. 8 (7) , 703-708
Open AccessTitanium-Nitride-Oxide–Coated vs Everolimus-Eluting Stents in Acute Coronary Syndrome
Importance: Titanium-nitride-oxide (TiNO)–coated stents show faster strut coverage compared with drug-eluting stents without excessive intimal-hyperplasia observed in bare metal stents. It is important to study long-term clinical outcomes after treatment of patients with an acute coronary syndrome (ACS) by TiNO-coated stents, which are neither drug-eluting stents nor bare metal stents.Objective: To compare the rate of main composite outcome of cardiac death, myocardial infarction (MI), or ischemia-driven target lesion revascularization at 5 years in patients with ACS randomized to receive either a TiNO-coated stent or a third-generation everolimus-eluting stent (EES).Design, Setting, and Participants: This multicenter, randomized, controlled, open-label trial was conducted in 12 clinical sites in 5 European countries and enrolled patients from January 2014 to August 2016. Patients presenting with ACS (ST-segment elevation MI, non–ST-segment elevation MI, and unstable angina) with at least 1 de novo lesion were randomized to receive either a TiNO-coated stent or an EES. The present report analyzes the long-term follow-up for the main composite outcome and its individual components. Analysis took place between November 2022 to March 2023.Main outcome: The primary end point was a composite of cardiac death, MI, or target lesion revascularization at 12-month follow-up.Results: A total of 1491 patients with ACS were randomly assigned to receive either TiNO-coated stents (989 [66.3%]) or EES (502 [33.7%]). The mean (SD) age was 62.7 (10.8) years, and 363 (24.3%) were female. At 5 years, the main composite outcome events occurred in 111 patients (11.2%) in the TiNO group vs 60 patients (12%) in the EES group (hazard ratio [HR], 0.94; 95% CI, 0.69-1.28; P = .69). The rate of cardiac death was 0.9% (9 of 989) vs 3.0% (15 of 502) (HR, 0.30; 95% CI, 0.13-0.69; P = .005), the rate of MI was 4.6% (45 of 989) vs 7.0% (35 of 502) (HR, 0.64; 95% CI, 0.41-0.99; P = .049), the rate of stent thrombosis was 1.2% (12 of 989) vs 2.8% (14 of 502) (HR, 0.43; 95% CI, 0.20-0.93; P = .034), and the rate of target lesion revascularization was 7.4% (73 of 989) vs 6.4% (32 of 502) (HR, 1.16; 95% CI, 0.77-1.76; P = .47) in the TiNO-coated stent arm and in the EES arm, respectively.Conclusion and relevance: In this study, patients with ACS had a main composite outcome that was not different 5 years after TiNO-coated stent or EES.Trial Registration: ClinicalTrials.gov Identifier: NCT02049229
- Open Access
- 7 December 2022
- Published by MDPI AG in Biomedicines
- Vol. 10 (12) , 3159
Efficacy and Safety of TiNO-Coated Stents versus Drug-Eluting Stents in Acute Coronary Syndrome: Systematic Literature Review and Meta-Analysis
(1) Background: Practice guidelines define drug-eluting stents (DES) as the standard of care in coronary percutaneous coronary intervention (PCI), including in acute coronary syndrome (ACS). This is based on comparisons with bare-metal stents (BMS). However, non-drug-eluting titanium-nitride-oxide-coated stents (TiNOS) have not been taken into account. The objective of this study is to determine whether TiNOS can be used as an alternative to DES in ACS. (2) Methods: A prospective systematic literature review (SLR), conducted according to the PRISMA guidelines, was performed, wherein multiple literature databases from 2018 and 2022 were searched. Prospective, randomised, controlled trials comparing outcomes after PCI with TiNOS vs. DES in any coronary artery disease (CAD) were searched. Clinical outcomes were meta-analytic pooled risk ratios (RR) of device-oriented Major Adverse Cardiac Events (MACE) and their components. The analysis stratified outcomes reported with ACS-only vs. ACS jointly with chronic coronary syndrome (CCS). (3) Results: Five RCTs were eligible, comprising 1855 patients with TiNOS vs. 1363 with DES at a 1-year follow-up. Three enrolled patients presented with ACS only and two with ACS or CCS. The latter accounted for most of the patients. The one-year pooled RRs in those three RCTs were as follows: MACE 0.93 [0.72, 1.20], recurrent myocardial infarction (MI) 0.48 [0.31, 0.73], cardiac death (CD) 0.66 [0.33, 1.31], clinically driven target lesion revascularization (TLR) 1.55 [1.10, 2.19], and stent thrombosis (ST) 0.35 [0.20, 0.64]. Those results were robust to a sensitivity analysis. The evidence certainty was high in MACE and moderate or low in the other endpoints. (4) Conclusions: TiNOS are a non-inferior and safe alternative to DES in patients with ACS.
- 7 December 2022
- Published by MDPI AG in Biomedicines
- Vol. 10 (12) , 3159
Open AccessEfficacy and Safety of TiNO-Coated Stents versus Drug-Eluting Stents in Acute Coronary Syndrome: Systematic Literature Review and Meta-Analysis
(1) Background: Practice guidelines define drug-eluting stents (DES) as the standard of care in coronary percutaneous coronary intervention (PCI), including in acute coronary syndrome (ACS). This is based on comparisons with bare-metal stents (BMS). However, non-drug-eluting titanium-nitride-oxide-coated stents (TiNOS) have not been taken into account. The objective of this study is to determine whether TiNOS can be used as an alternative to DES in ACS. (2) Methods: A prospective systematic literature review (SLR), conducted according to the PRISMA guidelines, was performed, wherein multiple literature databases from 2018 and 2022 were searched. Prospective, randomised, controlled trials comparing outcomes after PCI with TiNOS vs. DES in any coronary artery disease (CAD) were searched. Clinical outcomes were meta-analytic pooled risk ratios (RR) of device-oriented Major Adverse Cardiac Events (MACE) and their components. The analysis stratified outcomes reported with ACS-only vs. ACS jointly with chronic coronary syndrome (CCS). (3) Results: Five RCTs were eligible, comprising 1855 patients with TiNOS vs. 1363 with DES at a 1-year follow-up. Three enrolled patients presented with ACS only and two with ACS or CCS. The latter accounted for most of the patients. The one-year pooled RRs in those three RCTs were as follows: MACE 0.93 [0.72, 1.20], recurrent myocardial infarction (MI) 0.48 [0.31, 0.73], cardiac death (CD) 0.66 [0.33, 1.31], clinically driven target lesion revascularization (TLR) 1.55 [1.10, 2.19], and stent thrombosis (ST) 0.35 [0.20, 0.64]. Those results were robust to a sensitivity analysis. The evidence certainty was high in MACE and moderate or low in the other endpoints. (4) Conclusions: TiNOS are a non-inferior and safe alternative to DES in patients with ACS.
- Open Access
- 21 June 2021
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 22 (12) , 6630
Epitranscriptomics of Ischemic Heart Disease—The IHD-EPITRAN Study Design and Objectives
Epitranscriptomic modifications in RNA can dramatically alter the way our genetic code is deciphered. Cells utilize these modifications not only to maintain physiological processes, but also to respond to extracellular cues and various stressors. Most often, adenosine residues in RNA are targeted, and result in modifications including methylation and deamination. Such modified residues as N-6-methyl-adenosine (m6A) and inosine, respectively, have been associated with cardiovascular diseases, and contribute to disease pathologies. The Ischemic Heart Disease Epitranscriptomics and Biomarkers (IHD-EPITRAN) study aims to provide a more comprehensive understanding to their nature and role in cardiovascular pathology. The study hypothesis is that pathological features of IHD are mirrored in the blood epitranscriptome. The IHD-EPITRAN study focuses on m6A and A-to-I modifications of RNA. Patients are recruited from four cohorts: (I) patients with IHD and myocardial infarction undergoing urgent revascularization; (II) patients with stable IHD undergoing coronary artery bypass grafting; (III) controls without coronary obstructions undergoing valve replacement due to aortic stenosis and (IV) controls with healthy coronaries verified by computed tomography. The abundance and distribution of m6A and A-to-I modifications in blood RNA are charted by quantitative and qualitative methods. Selected other modified nucleosides as well as IHD candidate protein and metabolic biomarkers are measured for reference. The results of the IHD-EPITRAN study can be expected to enable identification of epitranscriptomic IHD biomarker candidates and potential drug targets.
- 21 June 2021
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 22 (12) , 6630
Open AccessEpitranscriptomics of Ischemic Heart Disease—The IHD-EPITRAN Study Design and Objectives
Epitranscriptomic modifications in RNA can dramatically alter the way our genetic code is deciphered. Cells utilize these modifications not only to maintain physiological processes, but also to respond to extracellular cues and various stressors. Most often, adenosine residues in RNA are targeted, and result in modifications including methylation and deamination. Such modified residues as N-6-methyl-adenosine (m6A) and inosine, respectively, have been associated with cardiovascular diseases, and contribute to disease pathologies. The Ischemic Heart Disease Epitranscriptomics and Biomarkers (IHD-EPITRAN) study aims to provide a more comprehensive understanding to their nature and role in cardiovascular pathology. The study hypothesis is that pathological features of IHD are mirrored in the blood epitranscriptome. The IHD-EPITRAN study focuses on m6A and A-to-I modifications of RNA. Patients are recruited from four cohorts: (I) patients with IHD and myocardial infarction undergoing urgent revascularization; (II) patients with stable IHD undergoing coronary artery bypass grafting; (III) controls without coronary obstructions undergoing valve replacement due to aortic stenosis and (IV) controls with healthy coronaries verified by computed tomography. The abundance and distribution of m6A and A-to-I modifications in blood RNA are charted by quantitative and qualitative methods. Selected other modified nucleosides as well as IHD candidate protein and metabolic biomarkers are measured for reference. The results of the IHD-EPITRAN study can be expected to enable identification of epitranscriptomic IHD biomarker candidates and potential drug targets.
- Open Access
Efficacy and safety of TiNO-coated stents versus drug-eluting coronary stents. Systematic literature review and meta-analysis
Objectives: To compare clinical outcomes after percutaneous coronary intervention (PCI) using titanium-nitride-oxide coated stents (TiNOS) versus drug-eluting stents (DES) in coronary artery disease (CAD) including acute coronary syndrome (ACS). Design: Prospective systematic literature (SLR) conducted according to PRISMA. Medline, Embase, Cochrane, Web of Science were searched in March 2018 and updated. Setting: Interventional cardiology. Participants: Patients with CAD, including ACS, requiring PCI. Interventions: All prospective randomized controlled trials (RCTs) that compared clinical outcomes after PCI with DES versus TiNOS. Outcome measures: The pooled risk ratios (RR), TiNOS over DES, with 95% confidence intervals (CI) are computed for device-oriented Major Adverse Cardiac Events (MACE), non-fatal myocardial infarction (MI), cardiac death (CD), clinically driven target lesion revascularization (TLR), probable or definite stent thrombosis (ST), total mortality, at one to five years after PCI. Pooled RRs are stratified according to baseline ACS versus other CAD. Sensitivity analysis (SA) and certainty of the evidence are rated per GRADE. Results: Five RCTs are eligible with 1,855 patients with TiNOS versus 1,363 with DES at 1-year follow-up and 783 versus 771 at 5-year. Three RCTs included patients with ACS only. One-year RRs in ACS are: MACE 0.93 [0.72, 1.20], MI 0.48 [0.31, 0.73], CD 0.66 [0.33, 1.31], TLR 1.55 [1.10, 2.19] and ST 0.35 [0.20, 0.64]. One-year MACE, MI, and ST are robust to SA. The certainty of the evidence is high in MACE, moderate in MI, and low or very low in the other endpoints. There are too few observations to conclude about other CAD and 5-year outcomes. However, 5-year interim results are consistent with 1-year conclusions. Conclusions: A similar risk of MACE is found in TiNOS and DES, with potentially fewer MI and ST but more TLR in TiNOS. TiNOS are safe and effective in ACS at 1-year follow-up. Registration: PROSPERO CRD42018090622 Strengths and limitations of this study: - Strengths: The level of certainty of the evidence is high for the primary endpoint at one-year follow-up in patients treated for acute coronary syndrome. The primary endpoint and critical secondary endpoints are robust to sensitivity analysis. - Limitations: Outcomes in patients treated for chronic coronary artery disease cannot be analyzed. The level of certainty of the evidence of secondary endpoints is moderate or low. Analysis of five-year outcomes is still at an interim stage.
Open AccessEfficacy and safety of TiNO-coated stents versus drug-eluting coronary stents. Systematic literature review and meta-analysis
Objectives: To compare clinical outcomes after percutaneous coronary intervention (PCI) using titanium-nitride-oxide coated stents (TiNOS) versus drug-eluting stents (DES) in coronary artery disease (CAD) including acute coronary syndrome (ACS). Design: Prospective systematic literature (SLR) conducted according to PRISMA. Medline, Embase, Cochrane, Web of Science were searched in March 2018 and updated. Setting: Interventional cardiology. Participants: Patients with CAD, including ACS, requiring PCI. Interventions: All prospective randomized controlled trials (RCTs) that compared clinical outcomes after PCI with DES versus TiNOS. Outcome measures: The pooled risk ratios (RR), TiNOS over DES, with 95% confidence intervals (CI) are computed for device-oriented Major Adverse Cardiac Events (MACE), non-fatal myocardial infarction (MI), cardiac death (CD), clinically driven target lesion revascularization (TLR), probable or definite stent thrombosis (ST), total mortality, at one to five years after PCI. Pooled RRs are stratified according to baseline ACS versus other CAD. Sensitivity analysis (SA) and certainty of the evidence are rated per GRADE. Results: Five RCTs are eligible with 1,855 patients with TiNOS versus 1,363 with DES at 1-year follow-up and 783 versus 771 at 5-year. Three RCTs included patients with ACS only. One-year RRs in ACS are: MACE 0.93 [0.72, 1.20], MI 0.48 [0.31, 0.73], CD 0.66 [0.33, 1.31], TLR 1.55 [1.10, 2.19] and ST 0.35 [0.20, 0.64]. One-year MACE, MI, and ST are robust to SA. The certainty of the evidence is high in MACE, moderate in MI, and low or very low in the other endpoints. There are too few observations to conclude about other CAD and 5-year outcomes. However, 5-year interim results are consistent with 1-year conclusions. Conclusions: A similar risk of MACE is found in TiNOS and DES, with potentially fewer MI and ST but more TLR in TiNOS. TiNOS are safe and effective in ACS at 1-year follow-up. Registration: PROSPERO CRD42018090622 Strengths and limitations of this study: - Strengths: The level of certainty of the evidence is high for the primary endpoint at one-year follow-up in patients treated for acute coronary syndrome. The primary endpoint and critical secondary endpoints are robust to sensitivity analysis. - Limitations: Outcomes in patients treated for chronic coronary artery disease cannot be analyzed. The level of certainty of the evidence of secondary endpoints is moderate or low. Analysis of five-year outcomes is still at an interim stage.