Abstract
For modular power supplies based on Intermediate Bus Architectures (IBAs), efficient current sharing is essential for system reliability and lifespan. To achieve compact and drop-compensated current sharing, this article proposes a cross-stage voltage-shifting (CSVS) strategy combined with a Ripple-frequency modulated transmission (RFMT) mechanism for modular IBA converters. A compensation model incorporating power loss estimation is developed, enabling the first-stage converter to compute the precise load voltage compensation value using the local measurements. With RFMT, the value is encoded into the intermediate bus ripple by modulating the PWM carrier frequency. The second-stage converters, operating under droop control, demodulate the ripple frequency, and shift their reference voltages accordingly, achieving CSVS-based voltage drop compensation under varying load conditions. Without centralized controllers, communication buses, or current-sharing lines, the proposed strategy offers high scalability while reducing the hardware complexity and cost. Experimental results confirm the effectiveness of the proposed method in accurate current sharing, drop compensation, and fast dynamic response.
Funding Information
  • National Natural Science Foundation of China (62374067)
  • State Administration of Science, Technology, and Industry
  • National Defence of the People's Republic of China
  • National Key R&D Program of China (2024YFB4505400)