CMOS Platform for Neurochemical Detection Using 32 Graphene FETs Array at 16 kS/s per Channel
Authors:
- Rodrigo WregeRWRodrigo Wrege
- Mafalda AbrantesMAMafalda Abrantes
- Thiago Darós FernandesTFThiago Darós Fernandes
- Miguel BorgesMBMiguel Borges
- Helder AvelarHAHelder Avelar
- Accel AbarcaAAAccel Abarca
- Carlos MarquesCMCarlos Marques
- Álvaro GeraldesÁGÁlvaro Geraldes
- Jérôme BormeJBJérôme Borme
- Luis JacintoLJLuis Jacinto
- João PiteiraJPJoão Piteira
- Pedro AlpuimPedro Alpuim
Open Access
- 11 December 2025
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems I: Regular Papers
- Vol. 73 (3) , 1606-1618
Abstract
Graphene field-effect transistors (GFETs) are emerging sensors for monitoring chemical molecules in the brain due to their nanoscale dimensions and high sensitivity to ionic concentrations. In such systems, compact electronic readouts that allow high spatiotemporal resolution of dense sensor arrays are desired for improved brain spatial mapping at relevant physiological temporal scales. This work presents a CMOS-based platform capable of reading GFET arrays at a sampling rate of 512 kS/s, time-multiplexed across 32 channels, with an ENOB of 8.38 bits and a power consumption of $173~\mu $ W per channel. The ASIC, fabricated using a 180 nm CMOS process, has a core area of $970~\mu $ m $\times 500~\mu $ m and integrates a transimpedance amplifier, a fully differential amplifier, and a SAR ADC. This ASIC can be scalable to support larger GFET arrays. An All-Programmable System-on-Chip is employed for system control and real-time data acquisition, with data streamed via gigabit Ethernet to a computer for visualization and storage using custom-written software. Measurements in physiological buffers, such as phosphate-buffered saline (PBS) and dopamine diluted in artificial cerebrospinal fluid (aCSF), confirm the system’s capability for real-time current monitoring, analysis of V-shaped transfer curves, evaluation of frequency-doubling behavior, and spatiotemporal visualization of sensor responses to varying ionic conditions and targets.Keywords
This publication has 24 references indexed in Scilit:
- Analytical modeling and experimental characterization of drift in electrolyte-gated graphene field-effect transistorsnpj 2D Materials and Applications, 2025
- Graphene-Based Glucose Sensors with an Attomolar Limit of DetectionJournal of the American Chemical Society, 2025
- Wafer-Scale Graphene Field-Effect Transistor Biosensor Arrays with Monolithic CMOS ReadoutACS Applied Electronic Materials, 2023
- Graphene-Based Field-Effect Transistors in Biosensing and Neural Interfacing Applications: Recent Advances and ProspectsAnalytical Chemistry, 2023
- Programmable graphene-based microfluidic sensor for DNA detectionSensors and Actuators B: Chemical, 2022
- 3D integrated monolayer graphene–Si CMOS RF gas sensor platformnpj 2D Materials and Applications, 2017
- Operational Amplifiers2017
- Graphene/Si CMOS Hybrid Hall Integrated CircuitsScientific Reports, 2014
- CMOS-compatible graphene photodetector covering all optical communication bandsNature Photonics, 2013
- CMOS Analog Design Using All-Region MOSFET Modeling2010