Deep‐dished highly congruent tibial insert in CR‐TKA does not prevent patellar tendon angle increase and patellar anterior translation
- 12 February 2014
- journal article
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 23 (6) , 1622-1630
Abstract
Purpose: Starting from the hypothesis that a deep‐dished highly congruent tibial insert in cruciate‐retaining total knee arthroplasty would prevent the increase in patellar tendon angle and anterior patellar translation by reducing the paradoxical anterior femoral translation, the main purpose of the present study was to investigate the effect of this prosthesis design, and secondary to assess the clinical outcomes at 6‐month follow‐up.Methods: Twenty patients treated with cruciate‐retaining total knee arthroplasty with navigation technique were enrolled and prospectively followed up at 6 months. The median value of age was 71 years (57–83). Before and after surgery, the following parameters were calculated: patellar tendon angle, anterior–posterior and medio‐lateral patellar translation, patellar height and range of motion. All patients were assessed with the SF‐36 Physical Functioning and the Knee injury and Osteoarthritis Outcome Score ADL scores.Results: Patellar tendon angle and anterior patellar translation significantly increased in post‐operative conditions (p < 0.0001); a statistically significant medial patellar translation was found (p < 0.0001), while patellar height did not show any difference between pre‐ and post‐operative conditions (n.s). A significant correlation was found between patellar tendon angle and anterior patellar translation and the clinical scores (p < 0.0417). There was a significant post‐operative decrease (p < 0.0033) in the range of motion.Conclusions: The present study failed to demonstrate that deep‐dished highly congruent tibial insert prevents the anterior translation of the patella in cruciate‐retaining total knee arthroplasty, thus causing inferior clinical scores. It provided useful information about the biomechanical role of the patella in total knee arthroplasty, allowing to choose the most appropriate surgical approach.Level of evidence: Case series, Level IV.Keywords
This publication has 46 references indexed in Scilit:
- Patellar tilt correlates with vastus lateralis: Vastus medialis activation ratio in maltracking patellofemoral pain patientsJournal of Orthopaedic Research, 2011
- No difference in anterior tibial translation with and without posterior cruciate ligament in less invasive total knee replacementKnee Surgery, Sports Traumatology, Arthroscopy, 2011
- Comparison of five patellar height measurement methods in 90° knee flexionInternational Orthopaedics, 2011
- In vivopatellar kinematics during total knee arthroplastyComputer Aided Surgery, 2008
- Fluoroscopic analysis of the kinematics of deep flexion in total knee arthroplastyThe Journal of Bone and Joint Surgery. British volume, 2002
- Deep-Dish Congruent Tibial Component Use in Total Knee ArthroplastyClinical Orthopaedics and Related Research, 2000
- In vitro measurement of patellofemoral force after three types of knee replacementThe Journal of Bone and Joint Surgery. British volume, 1998
- Application of the Joint Coordinate System to Three-Dimensional Joint Attitude and Movement Representation: A Standardization ProposalJournal of Biomechanical Engineering, 1993
- The MOS 36-ltem Short-Form Health Survey (SF-36)Medical Care, 1992
- Radiological Assessment of Osteo-ArthrosisAnnals of the Rheumatic Diseases, 1957