Giovanni Francesco Raspugli
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Giovanni Francesco Raspugli has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Danilo Bruni
University of Study G. d’Annunzio
6 shared publications - Francesco Iacono
IRCCS Humanitas Research Hospital Rozzano Milan Italy
6 shared publications - Maurilio Marcacci
Istituto Ortopedico Rizzoli
6 shared publications - Ibrahim Akkawi
Istituto Ortopedico Rizzoli
5 shared publications - Simone Bignozzi
Codivilla-Putti Research Center, Rizzoli Orthopaedic Institute, Bologna, Italy.
3 shared publications - Stefano Zaffagnini
Clinica Ortopedica e Traumatologica II, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, Italy
3 shared publications
Latest Publications
- 8 September 2015
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 136 (1) , 117-123
Unicompartmental knee arthroplasty in patients over 75 years: a definitive solution?
The purpose of this study was to perform a mid-long-term clinical and radiographic evaluation of the results obtained in patients older than 75 years treated with minimally invasive unicompartmental knee arthroplasty (UKA). The hypothesis was that UKA is a viable solution for the definitive treatment of localized disease in this age group, with good results and a low failure rate.
- 8 September 2015
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 136 (1) , 117-123
Unicompartmental knee arthroplasty in patients over 75 years: a definitive solution?
The purpose of this study was to perform a mid-long-term clinical and radiographic evaluation of the results obtained in patients older than 75 years treated with minimally invasive unicompartmental knee arthroplasty (UKA). The hypothesis was that UKA is a viable solution for the definitive treatment of localized disease in this age group, with good results and a low failure rate.
- 4 September 2014
- Published by Springer Nature
- p. 1-6
Sports after Total Knee Prosthesis
- 11 June 2014
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 23 (11) , 3273-3280
Roentgen stereophotogrammetric analysis: an effective tool to predict implant survival after an all-poly unicompartmental knee arthroplasty—a 10 year follow-up study
The main purpose of the present study was to determine long-term implant fixation of 15 unicompartmental knee arthroplasty (UKAs) with an all-poly tibial component using Roentgen stereophotogrammetric analysis (RSA) at a mean 10-year follow-up. The secondary purpose was to investigate whether the progressive loss of implant’s fixation correlates with a reduction in Knee society score (KSS). Fifteen non-consecutive patients with primary knee osteoarthritis received a UKA with an all-poly tibial component were assessed using KSS scores pre-operatively and post-operatively and RSA on day 2 after surgery, then at 3, 6, and 12 months and yearly thereafter. The mean last follow-up was 10 years. An increase in maximum total point motion (MTPM) values from 6 months to 1 year post-operatively was found respect to post-operative reference. Implants’ displacement values were always p < 0.001). Also in a long-term follow-up evaluation, RSA is an effective tool to predict functional results after an all-poly UKA providing also a relevant predictive value at 1 year follow-up, and this can be very useful for both patients and surgeons. Diagnostic studies, Level III.
- 11 June 2014
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 23 (11) , 3273-3280
Roentgen stereophotogrammetric analysis: an effective tool to predict implant survival after an all-poly unicompartmental knee arthroplasty—a 10 year follow-up study
The main purpose of the present study was to determine long-term implant fixation of 15 unicompartmental knee arthroplasty (UKAs) with an all-poly tibial component using Roentgen stereophotogrammetric analysis (RSA) at a mean 10-year follow-up. The secondary purpose was to investigate whether the progressive loss of implant’s fixation correlates with a reduction in Knee society score (KSS). Fifteen non-consecutive patients with primary knee osteoarthritis received a UKA with an all-poly tibial component were assessed using KSS scores pre-operatively and post-operatively and RSA on day 2 after surgery, then at 3, 6, and 12 months and yearly thereafter. The mean last follow-up was 10 years. An increase in maximum total point motion (MTPM) values from 6 months to 1 year post-operatively was found respect to post-operative reference. Implants’ displacement values were always p < 0.001). Also in a long-term follow-up evaluation, RSA is an effective tool to predict functional results after an all-poly UKA providing also a relevant predictive value at 1 year follow-up, and this can be very useful for both patients and surgeons. Diagnostic studies, Level III.
- 12 February 2014
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 23 (6) , 1622-1630
Deep‐dished highly congruent tibial insert in CR‐TKA does not prevent patellar tendon angle increase and patellar anterior translation
Purpose: Starting from the hypothesis that a deep‐dished highly congruent tibial insert in cruciate‐retaining total knee arthroplasty would prevent the increase in patellar tendon angle and anterior patellar translation by reducing the paradoxical anterior femoral translation, the main purpose of the present study was to investigate the effect of this prosthesis design, and secondary to assess the clinical outcomes at 6‐month follow‐up.Methods: Twenty patients treated with cruciate‐retaining total knee arthroplasty with navigation technique were enrolled and prospectively followed up at 6 months. The median value of age was 71 years (57–83). Before and after surgery, the following parameters were calculated: patellar tendon angle, anterior–posterior and medio‐lateral patellar translation, patellar height and range of motion. All patients were assessed with the SF‐36 Physical Functioning and the Knee injury and Osteoarthritis Outcome Score ADL scores.Results: Patellar tendon angle and anterior patellar translation significantly increased in post‐operative conditions (p < 0.0001); a statistically significant medial patellar translation was found (p < 0.0001), while patellar height did not show any difference between pre‐ and post‐operative conditions (n.s). A significant correlation was found between patellar tendon angle and anterior patellar translation and the clinical scores (p < 0.0417). There was a significant post‐operative decrease (p < 0.0033) in the range of motion.Conclusions: The present study failed to demonstrate that deep‐dished highly congruent tibial insert prevents the anterior translation of the patella in cruciate‐retaining total knee arthroplasty, thus causing inferior clinical scores. It provided useful information about the biomechanical role of the patella in total knee arthroplasty, allowing to choose the most appropriate surgical approach.Level of evidence: Case series, Level IV.
- 12 February 2014
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 23 (6) , 1622-1630
Deep‐dished highly congruent tibial insert in CR‐TKA does not prevent patellar tendon angle increase and patellar anterior translation
Purpose: Starting from the hypothesis that a deep‐dished highly congruent tibial insert in cruciate‐retaining total knee arthroplasty would prevent the increase in patellar tendon angle and anterior patellar translation by reducing the paradoxical anterior femoral translation, the main purpose of the present study was to investigate the effect of this prosthesis design, and secondary to assess the clinical outcomes at 6‐month follow‐up.Methods: Twenty patients treated with cruciate‐retaining total knee arthroplasty with navigation technique were enrolled and prospectively followed up at 6 months. The median value of age was 71 years (57–83). Before and after surgery, the following parameters were calculated: patellar tendon angle, anterior–posterior and medio‐lateral patellar translation, patellar height and range of motion. All patients were assessed with the SF‐36 Physical Functioning and the Knee injury and Osteoarthritis Outcome Score ADL scores.Results: Patellar tendon angle and anterior patellar translation significantly increased in post‐operative conditions (p < 0.0001); a statistically significant medial patellar translation was found (p < 0.0001), while patellar height did not show any difference between pre‐ and post‐operative conditions (n.s). A significant correlation was found between patellar tendon angle and anterior patellar translation and the clinical scores (p < 0.0417). There was a significant post‐operative decrease (p < 0.0033) in the range of motion.Conclusions: The present study failed to demonstrate that deep‐dished highly congruent tibial insert prevents the anterior translation of the patella in cruciate‐retaining total knee arthroplasty, thus causing inferior clinical scores. It provided useful information about the biomechanical role of the patella in total knee arthroplasty, allowing to choose the most appropriate surgical approach.Level of evidence: Case series, Level IV.
- 28 June 2013
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 21 (11) , 2462-2467
Minimum thickness of all‐poly tibial component unicompartmental knee arthroplasty in patients younger than 60 years does not increase revision rate for aseptic loosening
Purpose: Management of unicompartmental knee osteoarthritis in middle‐aged patients is a challenging problem. Despite its functional advantages, UKA still raises questions concerning implant survivorship and an increased revision risk for aseptic loosening mainly due to polyethylene wear. The main purpose of the present study was to investigate whether using the minimum thickness of an all‐poly tibial UKA in patients under 60 years of age increases the revision rate for aseptic loosening. The secondary purposes were to compare implant survivorship with data reported in literature and to prospectively evaluate the clinical outcome in this selected group of patients.Methods: Thirty‐three consecutive patients under 60 years of age at the time of surgery with isolated medial compartment osteoarthritis underwent a unilateral medial UKA from 2002 to 2005 and were prospectively followed. A Kaplan–Meier analysis was performed to determine the 8‐year implant survivorship with revision for any reason as endpoint. KSS, WOMAC, Tegner–Lysholm, Tegner and VAS scores were prospectively evaluated at 3‐ to 8‐year follow‐up. Weight‐bearing radiographs were collected pre‐operatively and at 3‐ to 8‐year follow‐up to prospectively evaluate hip‐knee‐ankle angle (HKA), femoro‐tibial angle (FTA), tibial plateau angle and posterior tibial slope.Results: The 8‐year Kaplan–Meier survivorship with revision for any reason as endpoint was 83 %. Five failures were reported, and in 3 patients’ aseptic loosening of the tibial component was the reason for failure. All clinical scores significantly improved at 3‐year follow‐up, and no further modification was demonstrated up to 8‐year follow‐up. HKA, FTA and TPA had a significant difference at 3‐year follow‐up with respect to pre‐operative values (p < 0.01) and no further difference at 8‐year follow‐up was found.Conclusions: The present study failed to demonstrate an increased revision rate for aseptic loosening of the implant in patients under 60 years of age, who received an all‐poly tibial component UKA using the minimum thickness of the implant in all cases.Level of evidence: Case series, Level IV.
- 28 June 2013
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 21 (11) , 2462-2467
Minimum thickness of all‐poly tibial component unicompartmental knee arthroplasty in patients younger than 60 years does not increase revision rate for aseptic loosening
Purpose: Management of unicompartmental knee osteoarthritis in middle‐aged patients is a challenging problem. Despite its functional advantages, UKA still raises questions concerning implant survivorship and an increased revision risk for aseptic loosening mainly due to polyethylene wear. The main purpose of the present study was to investigate whether using the minimum thickness of an all‐poly tibial UKA in patients under 60 years of age increases the revision rate for aseptic loosening. The secondary purposes were to compare implant survivorship with data reported in literature and to prospectively evaluate the clinical outcome in this selected group of patients.Methods: Thirty‐three consecutive patients under 60 years of age at the time of surgery with isolated medial compartment osteoarthritis underwent a unilateral medial UKA from 2002 to 2005 and were prospectively followed. A Kaplan–Meier analysis was performed to determine the 8‐year implant survivorship with revision for any reason as endpoint. KSS, WOMAC, Tegner–Lysholm, Tegner and VAS scores were prospectively evaluated at 3‐ to 8‐year follow‐up. Weight‐bearing radiographs were collected pre‐operatively and at 3‐ to 8‐year follow‐up to prospectively evaluate hip‐knee‐ankle angle (HKA), femoro‐tibial angle (FTA), tibial plateau angle and posterior tibial slope.Results: The 8‐year Kaplan–Meier survivorship with revision for any reason as endpoint was 83 %. Five failures were reported, and in 3 patients’ aseptic loosening of the tibial component was the reason for failure. All clinical scores significantly improved at 3‐year follow‐up, and no further modification was demonstrated up to 8‐year follow‐up. HKA, FTA and TPA had a significant difference at 3‐year follow‐up with respect to pre‐operative values (p < 0.01) and no further difference at 8‐year follow‐up was found.Conclusions: The present study failed to demonstrate an increased revision rate for aseptic loosening of the implant in patients under 60 years of age, who received an all‐poly tibial component UKA using the minimum thickness of the implant in all cases.Level of evidence: Case series, Level IV.
- 29 June 2012
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 21 (12) , 2725-2729
The adductor tubercle: a reliable landmark for analysing the level of the femorotibial joint line
Purpose: The ratio of femoral width and distance from medial epicondyle to joint line helps estimate the femoral joint line position from femoral width. The approximately radial position of the medial epicondyle on femoral condyle spheres is probably responsible for this relationship, The adductor tubercle approximately lies diametrically opposite to the joint line on condylar sphere. Then, a linear correlation could also exist between the femoral width and distance of adductor tubercle to joint line and is the purpose of the current study.Methods: Femoral width, along with the distance to joint line from the medial epicondyle, the adductor tubercle and fibular pole, was measured on 110 standard antero‐posterior knee radiographs. Correlation between femoral width and these measurements was evaluated. The individual ratio of FW with adductor tubercle joint line, medial epicondyle joint line and fibula joint line was calculated using linear regression analysis. Intra‐observer and inter‐observer reliability was assessed.Results: Linear correlation was found between femoral width and distance of adductor tubercle to joint line (r = 0.83). It was more reliable than the correlation between femoral width and distance from medial epicondyle to joint line (r = 0.52). Inter‐observer repeatability was better for distance from adductor tubercle to joint line than for distance from medial epicondyle to joint line.Conclusions: We conclude that adductor tubercle can be used as a morphologic landmark to determine the knee joint line position, because a linear correlation between femoral width and distance from the adductor tubercle to the joint line was found.Level of evidence: Case series, Level IV.
- 29 June 2012
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 21 (12) , 2725-2729
The adductor tubercle: a reliable landmark for analysing the level of the femorotibial joint line
Purpose: The ratio of femoral width and distance from medial epicondyle to joint line helps estimate the femoral joint line position from femoral width. The approximately radial position of the medial epicondyle on femoral condyle spheres is probably responsible for this relationship, The adductor tubercle approximately lies diametrically opposite to the joint line on condylar sphere. Then, a linear correlation could also exist between the femoral width and distance of adductor tubercle to joint line and is the purpose of the current study.Methods: Femoral width, along with the distance to joint line from the medial epicondyle, the adductor tubercle and fibular pole, was measured on 110 standard antero‐posterior knee radiographs. Correlation between femoral width and these measurements was evaluated. The individual ratio of FW with adductor tubercle joint line, medial epicondyle joint line and fibula joint line was calculated using linear regression analysis. Intra‐observer and inter‐observer reliability was assessed.Results: Linear correlation was found between femoral width and distance of adductor tubercle to joint line (r = 0.83). It was more reliable than the correlation between femoral width and distance from medial epicondyle to joint line (r = 0.52). Inter‐observer repeatability was better for distance from adductor tubercle to joint line than for distance from medial epicondyle to joint line.Conclusions: We conclude that adductor tubercle can be used as a morphologic landmark to determine the knee joint line position, because a linear correlation between femoral width and distance from the adductor tubercle to the joint line was found.Level of evidence: Case series, Level IV.