Validation of the novel Deep Reality Viewer (DRV) 3D digital stereo viewer in otology surgery
- 22 February 2022
- journal article
- research article
- Published by Springer Nature in European Archives of Oto-Rhino-Laryngology
- Vol. 279 (10) , 4839-4845
Abstract
Purpose Magnification with accurate optic reproduction of the surgical field is essential in otology surgery, but current technologies are subject to specific disadvantages. This study aims to evaluate a novel 3D digital stereo viewer, the Deep Reality Viewer (DRV), in otology surgery, in comparison to both a 2D monitor and the gold standard of microscopy. Methods In this prospective clinical research study, ENT consultants and trainees evaluated visual and practical applications of the DRV. In visual assessment, participants (n = 11) viewed pre-recorded in vivo mastoid exploration displayed on a 2D monitor and the DRV screen. In practical assessment, participants (n = 9) performed otology surgical tasks on a cadaveric human head using both the microscope and DRV. Face, task-specific (TSV) and global content (GCV) outcomes were assessed using 5-point Likert scale questionnaires. Construct validity was assessed separately. Results The DRV achieved the pre-determined validation threshold of 4 for all validation parameters in both visual and practical assessment. The DRV significantly outperformed the 2D monitor in fourteen of 16 parameters. In comparison to microscopy, there was no significant difference in 13 of 16 parameters, with the DRV significantly outperforming in the remaining 3: defining anatomy (GCV), assessing middle ear anatomy (TSV) and overall TSV. Construct validity was not demonstrated for either technology. Conclusion The DRV achieved the validation threshold for all parameters, and outperformed the 2D monitor and microscopy in several parameters. This validates the DRV for performing otological procedures, and suggests that it would be a useful alternative to the gold standard of microscopy in otology surgery. Level of evidence N/A.Keywords
Funding Information
- Vision Engineering
This publication has 18 references indexed in Scilit:
- Three‐Dimensional Versus Two‐Dimensional Video‐Assisted Endoscopic Surgery: A Meta‐analysis of Clinical DataWorld Journal of Surgery, 2018
- Three-dimensional versus two-dimensional endoscopic-assisted thyroidectomy via the anterior chest approach: a preliminary reportSurgical Endoscopy, 2017
- Basic principles of endoscopic ear surgeryOperative Techniques in Otolaryngology-Head and Neck Surgery, 2017
- Three-dimensional laparoscopy vs 2-dimensional laparoscopy with high-definition technology for abdominal surgery: a systematic reviewThe American Journal of Surgery, 2017
- Three-dimensional versus two-dimensional vision in laparoscopy: a systematic reviewSurgical Endoscopy, 2015
- Two-Dimensional Versus Three-Dimensional Laparoscopy: Evaluation of Physicians' Performance and Preference Using a Pelvic TrainerJournal of Minimally Invasive Gynecology, 2015
- National survey of back & neck pain amongst consultant ophthalmologists in the United KingdomInternational Ophthalmology, 2015
- Comparative evaluation of HD 2D/3D laparoscopic monitors and benchmarking to a theoretically ideal 3D pseudodisplay: even well-experienced laparoscopists perform better with 3DSurgical Endoscopy, 2014
- Three-dimensional endoscopy in sinus surgeryCurrent Opinion in Otolaryngology & Head and Neck Surgery, 2013
- Transnasal 3D endoscopic skull base surgery: questionnaire-based analysis of the learning curve in 52 proceduresEuropean Archives of Oto-Rhino-Laryngology, 2013