Thomas Daniel Milner
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Thomas Daniel Milner has a total of 75 co-authors. Here are the top co-authors by number of shared publications:
- Jenny Montgomery
Department of Otolaryngology, Head and Neck Surgery, Queen Elizabeth University Hospital, Glasgow, UK
4 shared publications - Eitan Prisman
Division of Otolaryngology, Department of Surgery, Faculty of Medicine University of British Columbia Vancouver British Columbia Canada
3 shared publications Saleh Okhovat
Department of Otolaryngology, Queen Elizabeth University Hospital, Glasgow
3 shared publications- Arunachalam Iyer
Ear, Nose, and Throat Surgery Department University Hospital Monklands Airdrie UK
2 shared publications Georgios Kontorinis
Department of Otolaryngology, Head and Neck Surgery Queen Elizabeth University Hospital Glasgow UK
2 shared publicationsJamie J. Y. Kwon
Division of Otolaryngology – Head and Neck Surgery, Department of Surgery University of British Columbia Vancouver British Columbia Canada
2 shared publications
Latest Publications
- 25 October 2024
- Published by Cambridge University Press (CUP) in The Journal of Laryngology & Otology
- Vol. 139 (4) , 298-303
Feasibility and validation of a synthetic airway model for in situ laser dissection
Background: This study measured the effectiveness of an in-house designed, cast silicone airway model in addressing the lack of easily accessible, validated transoral laser microsurgery simulation models.Methods: Participants performed resection of two marked vocal fold lesions on the model. The model underwent face, content and construct validation assessment using a five-point Likert scale questionnaire measuring the mean resection time for each lesion and the completeness of lesion excision. Comparative analyses were performed for these measures.Results: Thirteen otolaryngologists participated in this study. The model achieved validation threshold on all face and content measures (median, ≥4). Construct validation was demonstrated by the improvement in mean resection time between lesions one and two (86 vs 54 seconds, W = 11, p = 0.017). The mean resection time was lower amongst more senior otolaryngologists (61.5 vs 107.1 seconds, W = 11, p = 0.017).Conclusion: This synthetic silicone model is a low-cost, easily reproducible, high-fidelity synthetic airway model, demonstrating face, content and construct validity.
- 25 October 2024
- Published by Cambridge University Press (CUP) in The Journal of Laryngology & Otology
- Vol. 139 (4) , 298-303
Feasibility and validation of a synthetic airway model for in situ laser dissection
Background: This study measured the effectiveness of an in-house designed, cast silicone airway model in addressing the lack of easily accessible, validated transoral laser microsurgery simulation models.Methods: Participants performed resection of two marked vocal fold lesions on the model. The model underwent face, content and construct validation assessment using a five-point Likert scale questionnaire measuring the mean resection time for each lesion and the completeness of lesion excision. Comparative analyses were performed for these measures.Results: Thirteen otolaryngologists participated in this study. The model achieved validation threshold on all face and content measures (median, ≥4). Construct validation was demonstrated by the improvement in mean resection time between lesions one and two (86 vs 54 seconds, W = 11, p = 0.017). The mean resection time was lower amongst more senior otolaryngologists (61.5 vs 107.1 seconds, W = 11, p = 0.017).Conclusion: This synthetic silicone model is a low-cost, easily reproducible, high-fidelity synthetic airway model, demonstrating face, content and construct validity.
- Open Access
- 4 October 2024
- Published by Wiley in Head & Neck
- Vol. 47 (2) , 640-650
Intraoperative Real‐Time Image‐Guided Fibular Harvest and Mandibular Reconstruction: A Feasibility Study on Cadaveric Specimens
Background: This study assesses the feasibility of real‐time surgical navigation to plan and guide sequential steps during mandible reconstruction on a series of cadaveric specimens.Methods: An image‐guided surgical (IGS) system was designed including customized mandible and fibula fixation devices with navigation reference frames and an accompanied image‐guided software. The mandibular and fibular segmental osteotomies were performed using the IGS in all five cadaveric patients. Procedural time and cephalometric measurements were recorded.Results: Five real‐time IGS mandibulectomy and fibular reconstruction were successfully performed. The mean Dice score and Hausdorff‐95 distance between the planned and actual mandible reconstructions was 0.8 ± 0.08 and 7.29 ± 4.81 mm, respectively. Intercoronoid width, interangle width, and mandible projection differences were 1.15 ± 1.17 mm, 0.9 ± 0.56 mm, and 1.47 ± 1.62 mm, respectively.Conclusion: This study presents the first demonstration of a comprehensive image‐guided workflow for mandibulectomy and fibular flap reconstruction on cadaveric specimens and resulted in adequate cephalometric accuracy.
- 4 October 2024
- Published by Wiley in Head & Neck
- Vol. 47 (2) , 640-650
Open AccessIntraoperative Real‐Time Image‐Guided Fibular Harvest and Mandibular Reconstruction: A Feasibility Study on Cadaveric Specimens
Background: This study assesses the feasibility of real‐time surgical navigation to plan and guide sequential steps during mandible reconstruction on a series of cadaveric specimens.Methods: An image‐guided surgical (IGS) system was designed including customized mandible and fibula fixation devices with navigation reference frames and an accompanied image‐guided software. The mandibular and fibular segmental osteotomies were performed using the IGS in all five cadaveric patients. Procedural time and cephalometric measurements were recorded.Results: Five real‐time IGS mandibulectomy and fibular reconstruction were successfully performed. The mean Dice score and Hausdorff‐95 distance between the planned and actual mandible reconstructions was 0.8 ± 0.08 and 7.29 ± 4.81 mm, respectively. Intercoronoid width, interangle width, and mandible projection differences were 1.15 ± 1.17 mm, 0.9 ± 0.56 mm, and 1.47 ± 1.62 mm, respectively.Conclusion: This study presents the first demonstration of a comprehensive image‐guided workflow for mandibulectomy and fibular flap reconstruction on cadaveric specimens and resulted in adequate cephalometric accuracy.
- Open Access
- 28 March 2024
- Published by Wiley in Head & Neck
- Vol. 46 (6) , 1322-1330
Evaluating the benefit of virtual surgical planning on bony union rates in head and neck reconstructive surgery
Objectives: Virtual surgical planning (VSP) has gained acceptance because of its benefits in obtaining adequate resection, achieving cephalometric accuracy, and reducing operative time. The aim of this study is to compare the rate of union between VSP and free‐hand surgery (FHS), identify predictors of non‐union and evaluate the difference in operative time.Methods: Post‐operative CT were retrospectively reviewed for 123 patients who underwent maxillary or mandibular reconstruction between 2014 and 2021 using either VSP or FHS. Each apposition was graded as complete, partial or non‐union. The rate of union, risk difference and inter‐rater reliability were calculated. The difference in operative time was assessed. Predictors of non‐union were identified using logistic regression.Results: A total of 326 appositions were graded (VSP n = 150; FHS n = 176). The rates of complete and partial union were higher with VSP than FHS (74.7% vs. 65.3%; 18% vs. 15.9%, respectively, p = 0.01). Non‐union was found at a higher rate with FHS than with VSP (18.7% vs. 7.3%). The non‐union risk difference was 11.4. FHS, major complications and apposition at the native bone were predictors of non‐union (OR 2.9, p = 0.02; OR 3.4, p = 0.01; OR 2.5, p = 0.05, respectively). The mean surgical time was shorter with VSP than with FHS (265.3 vs. 381.5 min, p < 0.001). The inter‐rater agreement was high (k = 0.85; ICC = 0.86).Conclusion: VSP demonstrated significantly higher bony union rates and shorter operative time. FHS, development of major complications and apposition with native bone correlated with non‐union.
- 28 March 2024
- Published by Wiley in Head & Neck
- Vol. 46 (6) , 1322-1330
Open AccessEvaluating the benefit of virtual surgical planning on bony union rates in head and neck reconstructive surgery
Objectives: Virtual surgical planning (VSP) has gained acceptance because of its benefits in obtaining adequate resection, achieving cephalometric accuracy, and reducing operative time. The aim of this study is to compare the rate of union between VSP and free‐hand surgery (FHS), identify predictors of non‐union and evaluate the difference in operative time.Methods: Post‐operative CT were retrospectively reviewed for 123 patients who underwent maxillary or mandibular reconstruction between 2014 and 2021 using either VSP or FHS. Each apposition was graded as complete, partial or non‐union. The rate of union, risk difference and inter‐rater reliability were calculated. The difference in operative time was assessed. Predictors of non‐union were identified using logistic regression.Results: A total of 326 appositions were graded (VSP n = 150; FHS n = 176). The rates of complete and partial union were higher with VSP than FHS (74.7% vs. 65.3%; 18% vs. 15.9%, respectively, p = 0.01). Non‐union was found at a higher rate with FHS than with VSP (18.7% vs. 7.3%). The non‐union risk difference was 11.4. FHS, major complications and apposition at the native bone were predictors of non‐union (OR 2.9, p = 0.02; OR 3.4, p = 0.01; OR 2.5, p = 0.05, respectively). The mean surgical time was shorter with VSP than with FHS (265.3 vs. 381.5 min, p < 0.001). The inter‐rater agreement was high (k = 0.85; ICC = 0.86).Conclusion: VSP demonstrated significantly higher bony union rates and shorter operative time. FHS, development of major complications and apposition with native bone correlated with non‐union.
- 11 November 2023
- Published by Wiley in Head & Neck
- Vol. 46 (2) , 249-261
Incidence and complications of hypothyroidism postlaryngectomy: A systematic review and meta‐analysis
Background: Hypothyroidism is common postlaryngectomy and is associated with laryngectomy‐specific complications. The objective of this study is to determine the incidence and predictors of hypothyroidism postlaryngectomy and its associated complications.Methods: Systematic review, data extraction, and meta‐analyses were performed following the PRISMA protocol. Six databases were searched for studies reporting on postlaryngectomy thyroid status with incidence, risk factors, management, or complications.Results: Fifty‐one studies with 6333 patients were included. The pooled incidence of postlaryngectomy hypothyroidism is 49% (CI 42%–57%). Subgroup analysis showed postlaryngectomy hypothyroidism rates significantly correlated with hemithyroidectomy and radiotherapy. Patients who underwent laryngectomy, hemithyroidectomy, and radiotherapy had a 65% (CI 59%–71%) rate of hypothyroidism; laryngectomy and hemithyroidectomy 46% (CI 33%–60%); laryngectomy and radiotherapy 26% (CI 19%–35%); and laryngectomy alone 11% (CI 4%–27%) (p < 0.001).Conclusions: Laryngectomized patients with partial thyroidectomy or radiation therapy are at significant risk of postoperative hypothyroidism. Evidence‐based protocols for early detection and (prophylactic) treatment should be established.
- 11 November 2023
- Published by Wiley in Head & Neck
- Vol. 46 (2) , 249-261
Incidence and complications of hypothyroidism postlaryngectomy: A systematic review and meta‐analysis
Background: Hypothyroidism is common postlaryngectomy and is associated with laryngectomy‐specific complications. The objective of this study is to determine the incidence and predictors of hypothyroidism postlaryngectomy and its associated complications.Methods: Systematic review, data extraction, and meta‐analyses were performed following the PRISMA protocol. Six databases were searched for studies reporting on postlaryngectomy thyroid status with incidence, risk factors, management, or complications.Results: Fifty‐one studies with 6333 patients were included. The pooled incidence of postlaryngectomy hypothyroidism is 49% (CI 42%–57%). Subgroup analysis showed postlaryngectomy hypothyroidism rates significantly correlated with hemithyroidectomy and radiotherapy. Patients who underwent laryngectomy, hemithyroidectomy, and radiotherapy had a 65% (CI 59%–71%) rate of hypothyroidism; laryngectomy and hemithyroidectomy 46% (CI 33%–60%); laryngectomy and radiotherapy 26% (CI 19%–35%); and laryngectomy alone 11% (CI 4%–27%) (p < 0.001).Conclusions: Laryngectomized patients with partial thyroidectomy or radiation therapy are at significant risk of postoperative hypothyroidism. Evidence‐based protocols for early detection and (prophylactic) treatment should be established.
- 29 April 2022
- Published by Cambridge University Press (CUP) in The Journal of Laryngology & Otology
- Vol. 137 (4) , 368-372
Temperature and luminosity outputs of endoscopes used in transcanal endoscopic ear surgery: an experimental study
Objective: To establish the relationship between endoscope temperatures and luminosity with a variety of light source types, endoscope ages, endoscope sizes, angles and operative distance in transcanal endoscopic ear surgery.Methods: Transcanal endoscopic ear surgery was simulated in an operating theatre using 7 mm plastic suction tubing coated in insulating tape. An ATP ET-959 thermometer was used to record temperatures, and a Trotec BF06 lux meter was used to measure luminosity. Luminosity and temperature recordings were taken at 0 mm and 5 mm from the endoscope tip.Results: Thermal energy transfer from operating endoscopes is greatest when: the light intensity is high, there is a light-emitting diode light source and the endoscope is touching the surface. Additionally, larger-diameter endoscopes, angled endoscopes and new endoscopes generated greater heat.Conclusion: It is recommended that operative light intensity is maintained at the lowest level possible, and that the surgeon avoids contact between patient tissues and the endoscope tip.
- 29 April 2022
- Published by Cambridge University Press (CUP) in The Journal of Laryngology & Otology
- Vol. 137 (4) , 368-372
Temperature and luminosity outputs of endoscopes used in transcanal endoscopic ear surgery: an experimental study
Objective: To establish the relationship between endoscope temperatures and luminosity with a variety of light source types, endoscope ages, endoscope sizes, angles and operative distance in transcanal endoscopic ear surgery.Methods: Transcanal endoscopic ear surgery was simulated in an operating theatre using 7 mm plastic suction tubing coated in insulating tape. An ATP ET-959 thermometer was used to record temperatures, and a Trotec BF06 lux meter was used to measure luminosity. Luminosity and temperature recordings were taken at 0 mm and 5 mm from the endoscope tip.Results: Thermal energy transfer from operating endoscopes is greatest when: the light intensity is high, there is a light-emitting diode light source and the endoscope is touching the surface. Additionally, larger-diameter endoscopes, angled endoscopes and new endoscopes generated greater heat.Conclusion: It is recommended that operative light intensity is maintained at the lowest level possible, and that the surgeon avoids contact between patient tissues and the endoscope tip.
- 22 February 2022
- Published by Springer Nature in European Archives of Oto-Rhino-Laryngology
- Vol. 279 (10) , 4839-4845
Validation of the novel Deep Reality Viewer (DRV) 3D digital stereo viewer in otology surgery
Purpose Magnification with accurate optic reproduction of the surgical field is essential in otology surgery, but current technologies are subject to specific disadvantages. This study aims to evaluate a novel 3D digital stereo viewer, the Deep Reality Viewer (DRV), in otology surgery, in comparison to both a 2D monitor and the gold standard of microscopy. Methods In this prospective clinical research study, ENT consultants and trainees evaluated visual and practical applications of the DRV. In visual assessment, participants (n = 11) viewed pre-recorded in vivo mastoid exploration displayed on a 2D monitor and the DRV screen. In practical assessment, participants (n = 9) performed otology surgical tasks on a cadaveric human head using both the microscope and DRV. Face, task-specific (TSV) and global content (GCV) outcomes were assessed using 5-point Likert scale questionnaires. Construct validity was assessed separately. Results The DRV achieved the pre-determined validation threshold of 4 for all validation parameters in both visual and practical assessment. The DRV significantly outperformed the 2D monitor in fourteen of 16 parameters. In comparison to microscopy, there was no significant difference in 13 of 16 parameters, with the DRV significantly outperforming in the remaining 3: defining anatomy (GCV), assessing middle ear anatomy (TSV) and overall TSV. Construct validity was not demonstrated for either technology. Conclusion The DRV achieved the validation threshold for all parameters, and outperformed the 2D monitor and microscopy in several parameters. This validates the DRV for performing otological procedures, and suggests that it would be a useful alternative to the gold standard of microscopy in otology surgery. Level of evidence N/A.
- 22 February 2022
- Published by Springer Nature in European Archives of Oto-Rhino-Laryngology
- Vol. 279 (10) , 4839-4845
Validation of the novel Deep Reality Viewer (DRV) 3D digital stereo viewer in otology surgery
Purpose Magnification with accurate optic reproduction of the surgical field is essential in otology surgery, but current technologies are subject to specific disadvantages. This study aims to evaluate a novel 3D digital stereo viewer, the Deep Reality Viewer (DRV), in otology surgery, in comparison to both a 2D monitor and the gold standard of microscopy. Methods In this prospective clinical research study, ENT consultants and trainees evaluated visual and practical applications of the DRV. In visual assessment, participants (n = 11) viewed pre-recorded in vivo mastoid exploration displayed on a 2D monitor and the DRV screen. In practical assessment, participants (n = 9) performed otology surgical tasks on a cadaveric human head using both the microscope and DRV. Face, task-specific (TSV) and global content (GCV) outcomes were assessed using 5-point Likert scale questionnaires. Construct validity was assessed separately. Results The DRV achieved the pre-determined validation threshold of 4 for all validation parameters in both visual and practical assessment. The DRV significantly outperformed the 2D monitor in fourteen of 16 parameters. In comparison to microscopy, there was no significant difference in 13 of 16 parameters, with the DRV significantly outperforming in the remaining 3: defining anatomy (GCV), assessing middle ear anatomy (TSV) and overall TSV. Construct validity was not demonstrated for either technology. Conclusion The DRV achieved the validation threshold for all parameters, and outperformed the 2D monitor and microscopy in several parameters. This validates the DRV for performing otological procedures, and suggests that it would be a useful alternative to the gold standard of microscopy in otology surgery. Level of evidence N/A.
- 24 February 2021
- Published by Wiley in Clinical Otolaryngology
- Vol. 46 (4) , 888-892
Learning curve in endoscopic tympanoplasties: A prospective study based on outcomes of 141 cases
Click on the article title to read more.
- 24 February 2021
- Published by Wiley in Clinical Otolaryngology
- Vol. 46 (4) , 888-892
Learning curve in endoscopic tympanoplasties: A prospective study based on outcomes of 141 cases
Click on the article title to read more.
- 19 July 2020
- Published by Wiley in Clinical Otolaryngology
- Vol. 46 (1) , 138-145
Pan‐Scotland tonsillectomy outcomes: A national cross‐sectional study
Objectives: The aim of this study was to assess the current post‐tonsillectomy haemorrhage and return to theatre rates in Scotland.Design: National cross‐sectional study.Participants and setting: Tonsillectomy outcomes data were collated for all NHS patients undergoing tonsillectomy in Scotland between 1998‐2002 and 2013‐2017.Main outcome measures: Using Information Services Division (ISD) Scotland retrospective data, 30‐day re‐admission and 30‐day return to theatre rates allowed an assessment of post‐tonsillectomy haemorrhage rates. Data were validated through comparison with an audit conducted in NHS Greater Glasgow & Clyde between 2015 and 2016.Results: Tonsillectomy was performed in 27 819 patients between 1998 and 2002, and 23 184 patients between 2013 and 2017. 30‐day re‐admission rates increased considerably between the 1998‐2002 and 2013‐2017 cohorts, from 4.7% to 12.1% in paediatric patients, and 9.8%‐19.9% in adult patients. Similarly, 30‐day “return to theatre rates” increased between the two cohorts, from 1.2% to 1.7% in paediatric patients, and 3.6%‐4.9% in adult patients. Re‐admission and return to theatre rates were similar across Health Boards for both adult and paediatric tonsillectomies in each cohort.Conclusions: Current 30‐day re‐admission and return to theatre rates are significantly higher than the majority of reported series to date. The rising rate of tonsillectomy haemorrhage between cohorts is likely to be multifactorial, possibly reflecting an underestimation of previous rates and the changing profile of the tonsillectomy patient. A detailed audit of current practice is needed to investigate these tonsillectomy outcomes, which are similar across all Health Boards in Scotland. Of most significance are the implications for accurate patient consent and non‐elective ENT service provision.
- 19 July 2020
- Published by Wiley in Clinical Otolaryngology
- Vol. 46 (1) , 138-145
Pan‐Scotland tonsillectomy outcomes: A national cross‐sectional study
Objectives: The aim of this study was to assess the current post‐tonsillectomy haemorrhage and return to theatre rates in Scotland.Design: National cross‐sectional study.Participants and setting: Tonsillectomy outcomes data were collated for all NHS patients undergoing tonsillectomy in Scotland between 1998‐2002 and 2013‐2017.Main outcome measures: Using Information Services Division (ISD) Scotland retrospective data, 30‐day re‐admission and 30‐day return to theatre rates allowed an assessment of post‐tonsillectomy haemorrhage rates. Data were validated through comparison with an audit conducted in NHS Greater Glasgow & Clyde between 2015 and 2016.Results: Tonsillectomy was performed in 27 819 patients between 1998 and 2002, and 23 184 patients between 2013 and 2017. 30‐day re‐admission rates increased considerably between the 1998‐2002 and 2013‐2017 cohorts, from 4.7% to 12.1% in paediatric patients, and 9.8%‐19.9% in adult patients. Similarly, 30‐day “return to theatre rates” increased between the two cohorts, from 1.2% to 1.7% in paediatric patients, and 3.6%‐4.9% in adult patients. Re‐admission and return to theatre rates were similar across Health Boards for both adult and paediatric tonsillectomies in each cohort.Conclusions: Current 30‐day re‐admission and return to theatre rates are significantly higher than the majority of reported series to date. The rising rate of tonsillectomy haemorrhage between cohorts is likely to be multifactorial, possibly reflecting an underestimation of previous rates and the changing profile of the tonsillectomy patient. A detailed audit of current practice is needed to investigate these tonsillectomy outcomes, which are similar across all Health Boards in Scotland. Of most significance are the implications for accurate patient consent and non‐elective ENT service provision.
- 8 January 2020
- Published by Springer Nature in European Archives of Oto-Rhino-Laryngology
- Vol. 277 (4) , 1167-1175
Feasibility of ovine and porcine models for simulation training in parotid surgery and facial nerve dissection
To assess and compare the feasibility of using ovine and porcine models as surgical simulation training tools for otolaryngology trainees performing parotid surgery and facial nerve dissection.
- 8 January 2020
- Published by Springer Nature in European Archives of Oto-Rhino-Laryngology
- Vol. 277 (4) , 1167-1175
Feasibility of ovine and porcine models for simulation training in parotid surgery and facial nerve dissection
To assess and compare the feasibility of using ovine and porcine models as surgical simulation training tools for otolaryngology trainees performing parotid surgery and facial nerve dissection.