PET/CT image fusion error due to urinary bladder filling changes: consequence and correction
Authors:
- 29 September 2009
- journal article
- clinical trial
- Published by Springer Nature in Annals of Nuclear Medicine
- Vol. 23 (8) , 739-744
Abstract
A considerable change of urinary bladder (UB) shape in PET compared with CT in integrated PET/CT system is frequently noted. This study initially evaluated this finding with and without oral contrast (OC) use. In addition, a one bed pelvic section (PLV) repeat acquisition was investigated as a solution to this problem. 18FDG PET/CTs of 88 patients were analyzed. OC was administered in 68 patients, of whom 31 had PLV images taken 5–10 min later. Three-dimensional mid-UB CT and PET matching measurements were compared. In addition, UB walls displacement between CT and PET were analyzed. The mean UB height was significantly increased (P < 0.001) in PET when compared with CT, both anteriorly and posteriorly; however, UB width and depth were not significantly different. An upward shift of superior UB wall in PET from equivalent CT images was noted, whereas there was no appreciable displacement of the other UB walls. The percent UB height increase on PET from CT was significantly greater with than without OC use. The UB height difference between PET and CT was markedly reduced on PLV when compared with the original scans. Caution should be exerted during the interpretation of PET/CT scans of the pelvis as there is significant upward expansion of UB on PET compared with CT that appears to be exaggerated by OC use, likely due to additional fluid load. The PET/CT fusion errors of UB can be substantially resolved through a separate PLV acquisition presumably due to the shorter time interval of UB scan completion between CT and PET.Keywords
This publication has 6 references indexed in Scilit:
- Anterior Layering of Excreted 18F-FDG in the Bladder on PET/CT: Frequency and CauseAmerican Journal of Roentgenology, 2007
- PET/CT Imaging Techniques, Considerations, and ArtifactsJournal of Thoracic Imaging, 2006
- Positron Emission Tomography/Computed Tomography: Protocol Issues and OptionsSeminars in Nuclear Medicine, 2006
- Whole-body PET/CT: Spectrum of physiological variants, artifacts and interpretative pitfalls in cancer patientsNuclear Medicine Communications, 2005
- Pitfalls and artifacts in 18FDG PET and PET/CT oncologic imagingSeminars in Nuclear Medicine, 2004
- Dual-modality PET/CT imaging: the effect of respiratory motion on combined image quality in clinical oncologyEuropean Journal of Nuclear Medicine and Molecular Imaging, 2003