SHSherif Heiba

Sherif Heiba

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Sherif Heiba has a total of 37 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Evaluation of diabetic foot infection in nuclear medicine

    by Sherif Heiba, Karin Knešaurek

    Article: Evaluation of diabetic foot infection in nuclear medicine - The Quarterly Journal of Nuclear Medicine and Molecular Imaging 2017 September;61(3):283-91 - Minerva Medica - Journals


  • The ideal dual-isotope imaging combination in evaluating patients with suspected infection of pelvic pressure ulcers

    by Sherif I. Heiba, Lewen Stempler, Timothy Sullivan, Dov Kolker, Lale Kostakoglu

    Introduction The successful management of infected pelvic pressure ulcer patients (PPUP) depends on the distinction between infections limited to soft tissue (STI) and those with underlying osteomyelitis (OM), which can be difficult to determine clinically. Dual-isotope (DI) comprehensive imaging has excellent accuracy in localizing diabetic foot infection and differentiating OM from STI with SPECT/CT utilization. In this study, we assess the accuracy and confidence of the different DI SPECT/CT imaging steps in PPUP with confirmed diagnoses. Patients and methods Pelvic flow and blood pool imaging were followed by labeled white blood cell reinjection and Tc-99m hydroxymethylene-diphosphonate bone (bone scan) and In-111-leukocytes (white blood cell scan) DI planar and SPECT/CT (step 1) acquisitions. Tc-99m sulfur colloid (bone marrow scan)/WBCS SPECT/CT (step 2) images were obtained on the following day. DI step 1 planar, step 1 SPECT/CT, step 2 SPECT/CT, and combined step 1/step 2 SPECT/CT were reviewed separately for diagnosis and diagnosis confidence. The final diagnosis was confirmed by culture/pathology in 21 patients and clinical/imaging follow-up in 12 patients. Results There were 19 OM patients, three STI patients, and 11 patients with no infection. The final diagnosis agreement to DI combined step 1/step 2 SPECT/CT was higher than DI step 2 or step 1 SPECT/CT alone, or DI step 1 planar, as assessed by λ and error reduction %, respectively. Combined DI step 1/step 2 SPECT/CT was more sensitive than DI step 2 SPECT/CT and more specific than DI step 1 SPECT/CT, and showed higher diagnostic confidence than both imaging techniques. Conclusion DI SPECT/CT is highly useful in evaluating PPUP with suspected infection. DI step 1 is more sensitive, whereas step 2 is more specific. Both step 1 and step 2 DI SPECT/CT images are needed to accurately and confidently assess for infection and distinguish OM from STI, which are crucial for optimal management.


  • PET–CT of mesenteric panniculitis: A potential confounder of lymphoma

    by Panagiotis A. Sideras, Vivek Patil, Zhonghua Li, Sherif Heiba, Lale Kostakoglou


  • Dual-isotope SPECT/CT impact on hospitalized patients with suspected diabetic foot infection

    by Sherif Heiba, Dov Kolker, Leonard Ong, Shalini Sharma, Arlene Travis, Victoria Teodorescu, Sharif Ellozy, Lale Kostakoglu, Ina Savitch, Josef Machac

    Background Foot ulcer with suspected infection is one of the most common reasons for hospitalization and a major factor contributing to morbidity and high healthcare-related expenses among diabetic patients. Many patients will require amputation; however, major amputation is associated with an alarmingly high 5-year mortality rate. In this study, we assess the diagnosis and management of suspected foot infection in diabetic patients using dual-isotope (DI) single-photon emission computed tomography/computed tomography (SPECT/CT) compared with conventional imaging. Methods The diagnostic accuracy in and management of 227 patients who had undergone DI SPECT/CT was compared with that of 232 similar patients who had undergone conventional imaging including plain radiography, CT, planar bone scanning, planar indium-111 white blood cell scanning, and MRI. The duration of hospitalization was additionally compared between these two groups of patients after excluding patients with other active comorbidities. Results Soft-tissue infection, osteomyelitis with or without soft-tissue infection, and other bony pathologies were more accurately and confidently identified with DI SPECT/CT than with conventional imaging. DI SPECT/CT use was associated with significantly fewer major amputations and more selective bony resection as well as with shorter duration of hospitalization when compared with conventional imaging. Conclusion In this large population of diabetic patients with suspected foot infection DI SPECT/CT was more accurate in diagnosing and localizing infection compared with conventional imaging. In addition, DI SPECT/CT provided clear guidance and promoted many limb salvage procedures. Of equal importance to health economics, DI SPECT/CT use was associated with considerably reduced length of hospitalization compared with conventional imaging.


  • Mycobacterial pseudotumor of the plantar fascia: how common is it?

    by Panagiotis A. Sideras, Sherif Heiba, Josef Machac, Jaclyn Hechtman, Sridhar Vatti


  • The Optimized Evaluation of Diabetic Foot Infection by Dual Isotope SPECT/CT Imaging Protocol

    by Sherif I. Heiba, Dov Kolker, Bharat Mocherla, Karan Kapoor, Manli Jiang, Hongju Son, Balasubramanya Rangaswamy, Lale Kostakoglu, Ina Savitch, Maria DaCosta, et al.


  • Open Access

    Extraperitoneal urine leak after renal transplantation: the role of radionuclide imaging and the value of accompanying SPECT/CT - a case report

    by Hongju Son, Sherif Heiba, Lale Kostakoglu, Josef Machac

    Background: The differentiation of the nature of a fluid collection as a complication of kidney transplantation is important for management and treatment planning. Early and delayed radionuclide renography can play an important role in the evaluation of a urine leak. However, it is sometimes limited in the evaluation of the exact location and extent of a urine leak. Case Presentation: A 71-year-old male who had sudden anuria, scrotal swelling and elevated creatinine level after cadaveric renal transplantation performed Tc-99 m MAG3 renography to evaluate the renal function, followed by an ultrasound which was unremarkable. An extensive urine leak was evident on the planar images. However, an exact location of the urine leak was unknown. Accompanying SPECT/CT images confirmed a urine leak extending from the lower aspect of the transplant kidney to the floor of the pelvic cavity, presacral region and the scrotum via right inguinal canal as well as to the right abdominal wall. Conclusions: Renal scintigraphy is very useful to detect a urine leak after renal transplantation. However, planar imaging is sometimes limited in evaluating the anatomical location and extent of a urine leak accurately. In that case accompanying SPECT/CT images are very helpful and valuable to evaluate the anatomical relationships exactly.


  • PET/CT image fusion error due to urinary bladder filling changes: consequence and correction

    by Sherif I. Heiba, Barbara Raphael, Ivan Castellon, Erkan Altinyay, Nick Sandella, Gerald Rosen, Hussein M. Abdel-Dayem

    A considerable change of urinary bladder (UB) shape in PET compared with CT in integrated PET/CT system is frequently noted. This study initially evaluated this finding with and without oral contrast (OC) use. In addition, a one bed pelvic section (PLV) repeat acquisition was investigated as a solution to this problem. 18FDG PET/CTs of 88 patients were analyzed. OC was administered in 68 patients, of whom 31 had PLV images taken 5–10 min later. Three-dimensional mid-UB CT and PET matching measurements were compared. In addition, UB walls displacement between CT and PET were analyzed. The mean UB height was significantly increased (P < 0.001) in PET when compared with CT, both anteriorly and posteriorly; however, UB width and depth were not significantly different. An upward shift of superior UB wall in PET from equivalent CT images was noted, whereas there was no appreciable displacement of the other UB walls. The percent UB height increase on PET from CT was significantly greater with than without OC use. The UB height difference between PET and CT was markedly reduced on PLV when compared with the original scans. Caution should be exerted during the interpretation of PET/CT scans of the pelvis as there is significant upward expansion of UB on PET compared with CT that appears to be exaggerated by OC use, likely due to additional fluid load. The PET/CT fusion errors of UB can be substantially resolved through a separate PLV acquisition presumably due to the shorter time interval of UB scan completion between CT and PET.


  • Combined rest redistribution thallium-201 SPECT and low-dose dobutamine contractility assessment in a simple and practical new viability protocol

    by Sherif I. Heiba, Gennie Yee, Hussein M. Abdel-Dayem, Irini Youssef, John Coppola

    Rest-redistribution (RR) thallium-201 (Tl-201) imaging is commonly used for myocardial viability evaluation. Contractile reserve (CR) assessment with low-dose dobutamine (LDD) is another method that highly predicts functional recovery following revascularization. In this study, we investigate the feasibility of a new protocol that provides combined Tl-201 uptake, resting and CR functional regional myocardial information in a single examination. A total of 41 patients underwent RR-gated-SPECT Tl-201 myocardial perfusion imaging. The LDD infusion was maintained during delayed imaging. Segmental Tl-201 uptake was classified into normal, fixed decrease (mild to absent) and reversible, and sub-classified by wall motion (WM)/thickening (WT) changes between early resting and delayed LDD gated images into normal, fixed or improved dysfunctional (CR present) segments. Out of 820 examined segments, 33 showed no appreciable Tl-201 uptake to evaluate WM/WT. In a dysfunctional myocardium, CR was significantly higher (P < 0.001) in reversible and fixed than in normal Tl-201 segments. The CR in dysfunctional segments with fixed decrease Tl-201 uptake was significantly higher (P < 0.05) in mild and moderate than in severe fixed defects. Both fixed Tl-201 defects and lack of CR were observed more (P < 0.05) in akinetic/dyskinetic than in hypokinetic segments. Simultaneous assessment of myocardial viability by RR Tl-201 uptake, resting and CR functional regional information is feasible and can be easily attained using this new protocol. Moreover, this protocol requires no additional time or radioactivity when compared with the usual RR Tl-201 protocol. Validation of this protocol with patients’ revascularization data is needed.