Respiratory modulations in the photoplethysmogram (DPOP) as a measure of respiratory effort
Open Access
- 16 September 2015
- journal article
- research article
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 30 (5) , 595-602
Abstract
DPOP is a measure of the strength of respiratory modulations present in the pulse oximetry photoplethysmogram (pleth) waveform. It has been proposed as a non-invasive parameter for the prediction of the response to volume expansion in hypovolemic patients. The effect of resistive breathing on the DPOP parameter was studied to determine whether it may have an adjunct use as a measure of respiratory effort. Healthy volunteers were tasked to breathe at fixed respiratory rates over a range of airway resistances generated by a flow resistor inserted within a mouthpiece. Changes in respiratory efforts, effected by the subjects and measured as airway pressures at the mouth, were compared to DPOP values derived from a finger pulse oximeter probe. It was found that the increased effort to breathe manifests itself as an associated increase in DPOP. Further, a relationship between DPOP and percent modulation of the pleth waveform was observed. A version of the DPOP algorithm that corrects for low perfusion was implemented which resulted in an improved relationship between DPOP and PPV. Although a limited cohort of seven volunteers was used, the results suggest that DPOP may be useful as a respiratory effort parameter, given that the fluid level of the patient is maintained at a constant level over the period of analysis.Keywords
This publication has 29 references indexed in Scilit:
- Variability in protocols on donation after circulatory death in EuropeCritical Care, 2013
- Pulse oximeter plethysmograph variation and its relationship to the arterial waveform in mechanically ventilated childrenJournal of Clinical Monitoring and Computing, 2012
- Developing an algorithm for pulse oximetry derived respiratory rate (RRoxi): a healthy volunteer studyJournal of Clinical Monitoring and Computing, 2012
- Photoplethysmographic and pulse pressure variations during abdominal surgeryActa Anaesthesiologica Scandinavica, 2011
- Does the Pleth Variability Index Indicate the Respiratory-Induced Variation in the Plethysmogram and Arterial Pressure Waveforms?Anesthesia & Analgesia, 2008
- Photoplethysmography: Beyond the Calculation of Arterial Oxygen Saturation and Heart RateAnesthesia & Analgesia, 2007
- Respiratory Variations in Pulse Oximetry Plethysmographic Waveform Amplitude to Predict Fluid Responsiveness in the Operating RoomAnesthesiology, 2007
- Respiratory variations in pulse oximeter waveform amplitude are influenced by venous return in mechanically ventilated patients under general anaesthesia2007
- Standard pulse oximeters can be used to monitor respiratory rateEmergency Medicine Journal, 2003
- Microvascular blood flow and skin temperature changes in the fingers following a deep inspiratory gaspPhysiological Measurement, 2002