Characterization of a Modified Clinical Linear Accelerator for Ultra-High Dose Rate Beam Delivery
Authors:
- Umberto DeutUDUmberto Deut
- Aurora CamperiACAurora Camperi
- Cristiano CavicchiCCCristiano Cavicchi
- Roberto CirioRCRoberto Cirio
- Emanuele Maria DataEDEmanuele Maria Data
- Elisabetta Alessandra DurisiEDElisabetta Alessandra Durisi
- Veronica FerreroVFVeronica Ferrero
- Arianna FerroAFArianna Ferro
- Simona GiordanengoSGSimona Giordanengo
- Oscar Martì VillarrealOVOscar Martì Villarreal
- Felix Mas MilianFMFelix Mas Milian
- Elisabetta MedinaEMElisabetta Medina
Open Access
- 27 August 2024
- journal article
- research article
- Published by MDPI AG in Applied Sciences
- Vol. 14 (17) , 7582
Abstract
Irradiations at Ultra-High Dose Rate (UHDR) regimes, exceeding 40 Gy/s in single fractions lasting less than 200 ms, have shown an equivalent antitumor effect compared to conventional radiotherapy with reduced harm to normal tissues. This work details the hardware and software modifications implemented to deliver 10 MeV UHDR electron beams with a linear accelerator Elekta SL 18 MV and the beam characteristics obtained. GafChromic EBT XD films and an Advanced Markus chamber were used for dosimetry characterization, while a silicon sensor assessed the machine’s beam pulses stability and repeatability. The dose per pulse, average dose rate and instantaneous dose rate in the pulse were evaluated for four experimental settings, varying the source-to-surface distance and the beam collimation, i.e., with and without the use of a cylindrical applicator. The results showed a dose per pulse from 0.6 Gy to a few tens of Gy and an average dose rate up to 300 Gy/s. The obtained results demonstrate the possibility to perform in vitro radiobiology experiments and test new technologies for beam monitoring and dosimetry at the upgraded LINAC, thus contributing to the electron UHDR research field.Keywords
All Related Versions
Funding Information
- National Institute for Nuclear Physics (INFN) (CSN5 Call 2021, “FRIDA”, VIGA S1921 EX-POST 21 01, “OPEN ACCES LABS” (2015), n.2015.AI1430.U1925)
- National Institute for Nuclear Physics (INFN), CSN5 Call 2021, project “FRIDA” (CSN5 Call 2021, “FRIDA”, VIGA S1921 EX-POST 21 01, “OPEN ACCES LABS” (2015), n.2015.AI1430.U1925)
- Compagnia di San Paolo (CSN5 Call 2021, “FRIDA”, VIGA S1921 EX-POST 21 01, “OPEN ACCES LABS” (2015), n.2015.AI1430.U1925)
- CRT Foundationgrant (CSN5 Call 2021, “FRIDA”, VIGA S1921 EX-POST 21 01, “OPEN ACCES LABS” (2015), n.2015.AI1430.U1925)
This publication has 25 references indexed in Scilit:
- Technical note: Commissioning of a linear accelerator producing ultra‐high dose rate electronsMedical Physics, 2023
- Perspectives in linear accelerator for FLASH VHEE: Study of a compact C-band systemPhysica Medica, 2022
- Ultra‐high dose rate dosimetry: Challenges and opportunities for FLASH radiation therapyMedical Physics, 2022
- Technical Note: FLASH radiotherapy monitor chamber signal conditioningMedical Physics, 2020
- Spatially fractionated radiation therapy: History, present and the futureClinical and Translational Radiation Oncology, 2020
- Modifying a clinical linear accelerator for delivery of ultra-high dose rate irradiationRadiotherapy and Oncology, 2019
- Challenges of dosimetry of ultra-short pulsed very high energy electron beamsPhysica Medica, 2017
- Irradiation in a flash: Unique sparing of memory in mice after whole brain irradiation with dose rates above 100 Gy/sRadiotherapy and Oncology, 2017
- Experimental Platform for Ultra-high Dose Rate FLASH Irradiation of Small Animals Using a Clinical Linear AcceleratorInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2017
- Assessment of clinically relevant dose distributions in pelvic IOERT using Gafchromic EBT3 filmsPhysica Medica, 2015