Felix Mas Milian
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Felix Mas Milian has a total of 199 co-authors. Here are the top co-authors by number of shared publications:
- Anna Vignati
Physics, Università degli Studi di Torino, Via Pietro Giuria 1, Torino, Piemonte, 10125, ITALY
12 shared publications - Simona Giordanengo
Istituto Nazionale di Fisica Nucleare Sezione di Torino, Via Pietro Giuria 1, Turin, Piedmont, 10125, Italy
11 shared publications - Roberto Cirio
INFN Sez. di Torino, Via Pietro Giuria, 1 10125 Torino
10 shared publications - Roberto Sacchi
Università degli Studi di Torino, Dipartimento di Fisica, via Pietro Giuria 1, Torino, Italy; Istituto Nazionale di Fisica Nucleare, Sezione di Torino, via Pietro Giuria 1, Torino, Italy
10 shared publications - Diango M. Montalvan Olivares
Università degli Studi di Torino, Via Pietro Giuria 1, Torino, Piemonte, 10125, Italy
8 shared publications - Emanuele Maria Data
Universita degli Studi di Torino, Via Pietro Giuria 1, Turin, Piedmont, 10124, Italy
6 shared publications
Latest Publications
- Open Access
- 12 May 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (10)
Prompt gamma timing for range verification with carbon ion irradiation: first experimental measurements and comparison with Geant4 Monte Carlo simulations
Prompt Gamma Timing (PGT) is a promising technique for in vivo range verification in particle therapy, exploiting the time-of-flight between primary particles and prompt gamma rays emitted by nuclear interactions. PGT distribution is highly sensitive to beam energy and target density, which, under controlled detector positioning, enables real-time monitoring of particle range, detection of morphological changes, and support for adaptive treatment strategies. Objective: This study investigates for the first time the application of PGT in carbon ion therapy. Approach: Measurements were performed using a dedicated detection system composed of a silicon strip sensor for primary ion timing and a LaBr3(Ce) scintillator read out by a SiPM matrix for secondary radiation. Carbon ion beams with energies of 166.41, 268.86, and 398.84 MeV/u irradiated a homogeneous 30.0 cm PMMA target at CNAO (Pavia, Italy). The secondary radiation detector was positioned at four off-beam positions to assess the robustness of the PGT technique. Monte Carlo simulations based on Geant4 were conducted for all configurations to evaluate agreement and predictive capability. Main Results: A quantitative bin-by-bin comparison of experimental and simulated PGT intensities demonstrated strong agreement within the 95% confidence interval, with no incompatible bins at 166.41 MeV/u, at most 1% at 268.86 MeV/u, and up to 8% at 398.84 MeV/u, depending on detector position. Prompt gammas were identified as the dominant contribution to the detected signals, particularly for detector positions upstream with respect to the primary particle beam, minimizing signal contamination from neutrons and charged fragments. Significance: The validated experimental - simulation framework confirms the capability of the proposed PGT system to resolve energy-dependent differences and highlights its potential for detecting clinically relevant changes in the particle beam range, supporting further development toward real-time monitoring in carbon ion therapy.
- 12 May 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (10)
Open AccessPrompt gamma timing for range verification with carbon ion irradiation: first experimental measurements and comparison with Geant4 Monte Carlo simulations
Prompt Gamma Timing (PGT) is a promising technique for in vivo range verification in particle therapy, exploiting the time-of-flight between primary particles and prompt gamma rays emitted by nuclear interactions. PGT distribution is highly sensitive to beam energy and target density, which, under controlled detector positioning, enables real-time monitoring of particle range, detection of morphological changes, and support for adaptive treatment strategies. Objective: This study investigates for the first time the application of PGT in carbon ion therapy. Approach: Measurements were performed using a dedicated detection system composed of a silicon strip sensor for primary ion timing and a LaBr3(Ce) scintillator read out by a SiPM matrix for secondary radiation. Carbon ion beams with energies of 166.41, 268.86, and 398.84 MeV/u irradiated a homogeneous 30.0 cm PMMA target at CNAO (Pavia, Italy). The secondary radiation detector was positioned at four off-beam positions to assess the robustness of the PGT technique. Monte Carlo simulations based on Geant4 were conducted for all configurations to evaluate agreement and predictive capability. Main Results: A quantitative bin-by-bin comparison of experimental and simulated PGT intensities demonstrated strong agreement within the 95% confidence interval, with no incompatible bins at 166.41 MeV/u, at most 1% at 268.86 MeV/u, and up to 8% at 398.84 MeV/u, depending on detector position. Prompt gammas were identified as the dominant contribution to the detected signals, particularly for detector positions upstream with respect to the primary particle beam, minimizing signal contamination from neutrons and charged fragments. Significance: The validated experimental - simulation framework confirms the capability of the proposed PGT system to resolve energy-dependent differences and highlights its potential for detecting clinically relevant changes in the particle beam range, supporting further development toward real-time monitoring in carbon ion therapy.
- Open Access
- 25 February 2026
- Published by Elsevier in Intelligent Systems with Applications
- Vol. 30
A novel FPGA-based time-to-digital converter featuring machine learning-aided self-calibration
- 25 February 2026
- Published by Elsevier in Intelligent Systems with Applications
- Vol. 30
Open AccessA novel FPGA-based time-to-digital converter featuring machine learning-aided self-calibration
- Open Access
- 27 October 2025
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 32 (6) , 1396-1402
Ultra-thin (<2 µm) silicon carbide free-standing membranes as beam position monitors for soft and tender X-ray beamlines
Conventional beam intensity monitor technologies, such as `gold-meshes' and `diamond conductive thin films', currently applied to tender and soft X-ray beams, encounter numerous application challenges, including diffraction effects, low signal strength, non-uniform transparency, and lack of position information. This study explores the potential of very thin (<2 µm) silicon carbide free-standing membranes, as in-line, minimally interfering beam intensity and position monitors, with high-lateral resolution, for soft and tender X-ray beamlines. Initial experimental assessments were conducted at the NanoMAX beamline at MAX IV to analyze the performance of such very thin devices in monitoring tightly focused (<1 µm FWHM) beams. The tests revealed that employing four-quadrant sensor layouts on such thin sensors resulted in significant charge collection losses in the regions between the quadrants and, under high electric field conditions, in charge multiplication effects (avalanche effects). Through Sentaurus TCAD theoretical simulations, the limitations of the four-quadrant design for such applications and the potential of an alternative technology (resistive X-ray beam postion monitor) were clarified.
- 27 October 2025
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 32 (6) , 1396-1402
Open AccessUltra-thin (<2 µm) silicon carbide free-standing membranes as beam position monitors for soft and tender X-ray beamlines
Conventional beam intensity monitor technologies, such as `gold-meshes' and `diamond conductive thin films', currently applied to tender and soft X-ray beams, encounter numerous application challenges, including diffraction effects, low signal strength, non-uniform transparency, and lack of position information. This study explores the potential of very thin (<2 µm) silicon carbide free-standing membranes, as in-line, minimally interfering beam intensity and position monitors, with high-lateral resolution, for soft and tender X-ray beamlines. Initial experimental assessments were conducted at the NanoMAX beamline at MAX IV to analyze the performance of such very thin devices in monitoring tightly focused (<1 µm FWHM) beams. The tests revealed that employing four-quadrant sensor layouts on such thin sensors resulted in significant charge collection losses in the regions between the quadrants and, under high electric field conditions, in charge multiplication effects (avalanche effects). Through Sentaurus TCAD theoretical simulations, the limitations of the four-quadrant design for such applications and the potential of an alternative technology (resistive X-ray beam postion monitor) were clarified.
- Open Access
- 29 July 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (16)
Real-time motion modeling and treatment verification for irregular motion in carbon ion therapy: a feasibility study
Objective: Irregular motion impacts treatment accuracy and can be compensated by larger margins or online adaptive approaches. A seamless workflow for fast and accurate 4D-dose reconstruction allows dosimetric monitoring intra- and inter-fractionally, as a basis for adaptive therapy. This study presents a real-time, motion-adaptive framework that combines motion modeling and treatment verification, integrated into the dose delivery and monitoring systems to enable continuous assessment of the delivered 4D-dose. Approach: The framework includes a GPU-based analytical algorithm for real-time dose reconstruction in carbon ion therapy, interfaced with the Dose Delivery and Optical Tracking Systems at the Centro Nazionale di Adroterapia Oncologica (CNAO). A motion model, driven by external surrogate tracking, generates a virtual CT every 150 ms, used for 4D-dose reconstruction with measured spot parameters. Planned and delivered doses are compared after each iso-energy slice. The framework was validated at CNAO using a geometric target and a 4D lung tumor phantom with a moving 2D ionization chamber array, under regular and irregular motion patterns. Main results: The framework successfully generated real-time CT images of the lung phantom, showing strong agreement with ground-truth images. Dose reconstructions were performed within inter-spill times during delivery, ensuring rapid assessment. Comparisons against detector measurements yielded an average gamma-index passing rate of 99% (3%/3mm), confirming the accuracy of both the motion model and the integrated treatment verification system. Significance: This work presents the first real-time framework for carbon ion therapy, integrating motion modeling and dose reconstruction to handle irregular motion, fully embedded in a clinic-like setup.
- 29 July 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (16)
Open AccessReal-time motion modeling and treatment verification for irregular motion in carbon ion therapy: a feasibility study
Objective: Irregular motion impacts treatment accuracy and can be compensated by larger margins or online adaptive approaches. A seamless workflow for fast and accurate 4D-dose reconstruction allows dosimetric monitoring intra- and inter-fractionally, as a basis for adaptive therapy. This study presents a real-time, motion-adaptive framework that combines motion modeling and treatment verification, integrated into the dose delivery and monitoring systems to enable continuous assessment of the delivered 4D-dose. Approach: The framework includes a GPU-based analytical algorithm for real-time dose reconstruction in carbon ion therapy, interfaced with the Dose Delivery and Optical Tracking Systems at the Centro Nazionale di Adroterapia Oncologica (CNAO). A motion model, driven by external surrogate tracking, generates a virtual CT every 150 ms, used for 4D-dose reconstruction with measured spot parameters. Planned and delivered doses are compared after each iso-energy slice. The framework was validated at CNAO using a geometric target and a 4D lung tumor phantom with a moving 2D ionization chamber array, under regular and irregular motion patterns. Main results: The framework successfully generated real-time CT images of the lung phantom, showing strong agreement with ground-truth images. Dose reconstructions were performed within inter-spill times during delivery, ensuring rapid assessment. Comparisons against detector measurements yielded an average gamma-index passing rate of 99% (3%/3mm), confirming the accuracy of both the motion model and the integrated treatment verification system. Significance: This work presents the first real-time framework for carbon ion therapy, integrating motion modeling and dose reconstruction to handle irregular motion, fully embedded in a clinic-like setup.
- Open Access
- 27 August 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (17) , 7582
Characterization of a Modified Clinical Linear Accelerator for Ultra-High Dose Rate Beam Delivery
Irradiations at Ultra-High Dose Rate (UHDR) regimes, exceeding 40 Gy/s in single fractions lasting less than 200 ms, have shown an equivalent antitumor effect compared to conventional radiotherapy with reduced harm to normal tissues. This work details the hardware and software modifications implemented to deliver 10 MeV UHDR electron beams with a linear accelerator Elekta SL 18 MV and the beam characteristics obtained. GafChromic EBT XD films and an Advanced Markus chamber were used for dosimetry characterization, while a silicon sensor assessed the machine’s beam pulses stability and repeatability. The dose per pulse, average dose rate and instantaneous dose rate in the pulse were evaluated for four experimental settings, varying the source-to-surface distance and the beam collimation, i.e., with and without the use of a cylindrical applicator. The results showed a dose per pulse from 0.6 Gy to a few tens of Gy and an average dose rate up to 300 Gy/s. The obtained results demonstrate the possibility to perform in vitro radiobiology experiments and test new technologies for beam monitoring and dosimetry at the upgraded LINAC, thus contributing to the electron UHDR research field.
- 27 August 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (17) , 7582
Open AccessCharacterization of a Modified Clinical Linear Accelerator for Ultra-High Dose Rate Beam Delivery
Irradiations at Ultra-High Dose Rate (UHDR) regimes, exceeding 40 Gy/s in single fractions lasting less than 200 ms, have shown an equivalent antitumor effect compared to conventional radiotherapy with reduced harm to normal tissues. This work details the hardware and software modifications implemented to deliver 10 MeV UHDR electron beams with a linear accelerator Elekta SL 18 MV and the beam characteristics obtained. GafChromic EBT XD films and an Advanced Markus chamber were used for dosimetry characterization, while a silicon sensor assessed the machine’s beam pulses stability and repeatability. The dose per pulse, average dose rate and instantaneous dose rate in the pulse were evaluated for four experimental settings, varying the source-to-surface distance and the beam collimation, i.e., with and without the use of a cylindrical applicator. The results showed a dose per pulse from 0.6 Gy to a few tens of Gy and an average dose rate up to 300 Gy/s. The obtained results demonstrate the possibility to perform in vitro radiobiology experiments and test new technologies for beam monitoring and dosimetry at the upgraded LINAC, thus contributing to the electron UHDR research field.
- Open Access
- 3 August 2024
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1068
A novel detector for 4D tracking in particle therapy
- 3 August 2024
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1068
Open AccessA novel detector for 4D tracking in particle therapy
- Open Access
- 25 March 2024
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1063
Monitoring of carbon ion therapeutic beams with thin silicon sensors
- 25 March 2024
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1063
Open AccessMonitoring of carbon ion therapeutic beams with thin silicon sensors