A New Single Work Bout Test to Estimate Critical Power and Anaerobic Work Capacity
Authors:
- Haley C BergstromHBHaley C Bergstrom
- Terry J HoushTHTerry J Housh
- Jorge M ZunigaJZJorge M Zuniga
- Clayton L CamicCCClayton L Camic
- Daniel A TraylorDTDaniel A Traylor
- Richard J SchmidtRSRichard J Schmidt
- Glen O JohnsonGJGlen O Johnson
- 1 March 2012
- journal article
- Published by Wolters Kluwer Health in Journal of Strength & Conditioning Research
- Vol. 26 (3) , 656-663
Abstract
Bergstrom, HC, Housh, TJ, Zuniga, JM, Camic, CL, Traylor, DA, Schmidt, RJ, and Johnson, GO. A new single work bout test to estimate critical power and anaerobic work capacity. J Strength Cond Res 26(3): 656–663, 2012—The purpose of this study was to develop a 3-minute, all-out test protocol using the Monark cycle ergometer for estimating the critical power (CP) and anaerobic work capacity (AWC) with the resistance based on body weight. Twelve moderately trained adults (mean age ± SD = 23.2 ± 3.5 years) performed an incremental cycle ergometer test to exhaustion. The CP and AWC were estimated from the original work limit (Wlim) vs. time limit (Tlim) relationship (CPPT) and a 3-minute all-out test (CP3min) against a fixed resistance and compared with the CP and AWC estimated from the new 3-minute tests on the Monark cycle ergometer (CP3.5% and CP4.5%). The resistance values for the CP3.5% and CP4.5% tests were set at 3.5 and 4.5% of the subject's body weight (kilograms). The results indicated that there were no significant differences (p > 0.05) among mean CP values for CPPT (178 ± 47 W), CP3.5% (173 ± 40 W), and CP4.5% (186 ± 44 W). The mean CP3min (193 ± 54 W), however, was significantly greater than CPPT and CP3.5%. There were no significant differences in AWC for the CPPT (13,412 ± 6,247 J), CP3min (10,895 ± 2,923 J), and CP4.5% (9,842 ± 4,394 J). The AWC values for the CPPT and CP3min, however, were significantly greater than CP3.5% (8,357 ± 2,946 J). The results of this study indicated that CP and AWC could be estimated from a single 3-minute work bout test on the Monark cycle ergometer with the resistance set at 4.5% of the body weight. A single work bout test with the resistance based on the individual's body weight provides a practical and accessible method to estimate CP and AWC.Keywords
This publication has 26 references indexed in Scilit:
- The effects of 4 weeks of an arginine-based supplement on the gas exchange threshold and peak oxygen uptakeApplied Physiology, Nutrition, and Metabolism, 2010
- Effects of Four Weeks of High-Intensity Interval Training and Creatine Supplementation on Critical Power and Anaerobic Working Capacity in College-Aged MenJournal of Strength & Conditioning Research, 2009
- Muscle metabolic responses to exercise above and below the “critical power” assessed using31P-MRSAmerican Journal of Physiology-Regulatory, Integrative and Comparative Physiology, 2008
- Robustness of a 3 min all‐out cycling test to manipulations of power profile and cadence in humansExperimental Physiology, 2007
- Preferred pedalling cadence in professional cyclingMedicine & Science in Sports & Exercise, 2001
- The Critical Power ConceptSports Medicine, 1993
- The accuracy of the critical power test for predicting time to exhaustion during cycle ergometryErgonomics, 1989
- A comparison between methods of measuring anaerobic work capacityErgonomics, 1988
- Metabolic and respiratory profile of the upper limit for prolonged exercise in manErgonomics, 1988
- THE WORK CAPACITY OF A SYNERGIC MUSCULAR GROUPErgonomics, 1965