Haley C. Bergstrom
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Haley C. Bergstrom has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Clayton L. Camic
University of Wisconsin–La Crosse
6 shared publicationsDaniel A. Traylor
University of Nebraska–Lincoln
6 shared publicationsGlen O. Johnson
University of Nebraska–Lincoln
6 shared publicationsJorge M. Zuniga
Creighton University
6 shared publicationsRichard J. Schmidt
University of Nebraska–Lincoln
6 shared publicationsTerry J. Housh
University of Nebraska–Lincoln
6 shared publications
Latest Publications
- 22 May 2013
- Published by Taylor & Francis in Research Quarterly for Exercise and Sport
- Vol. 84 (2) , 232-238
The Relationships Among Critical Power Determined From a 3-Min All-Out Test, Respiratory Compensation Point, Gas Exchange Threshold, and Ventilatory Threshold
Purpose: Critical power (CP) from the 3-min test was compared to the power outputs associated with thresholds determined from gas exchange parameters that have been used to demarcate the exercise-intensity domains including the respiratory compensation point (RCP), gas exchange threshold (GET), and ventilatory threshold (VT). Method: Twenty-eight participants performed an incremental-cycle ergometer test to exhaustion. The VT was determined from the relationship between the ventilatory equivalent for oxygen uptake (V˙E/V˙O2) versus V˙O2 and the GET was determined using the V-slope method (V˙CO2 vs. V˙O2). The RCP was identified from the V˙E-versus-V˙CO2 relationship. CP was the average power output during the last 30 s of the 3-min all-out test. Linear regression was used to determine the power outputs associated with the RCP, GET, and VT, as well as the V˙O2 associated with CP. Mean differences among the associated power outputs, percent V˙O2 peak, and percent peak power output for the GET, VT, RCP, and CP were analyzed using separate one-way repeated-measures analyses of variance. Results: There were no significant differences between CP (187 ± 47 W) and the power output associated with RCP (190 ± 49 W) or between the power outputs associated with GET (139 ± 37 W) and VT (145 ± 37 W). The power outputs associated with GET and VT, however, were significantly less than were those at CP and associated with RCP. Conclusions: These findings suggest CP and RCP demarcate the heavy from severe exercise-intensity domain and result from a different mechanism of fatigue than that of GET and VT, possibly hyperkalemia.
- 22 May 2013
- Published by Taylor & Francis in Research Quarterly for Exercise and Sport
- Vol. 84 (2) , 232-238
The Relationships Among Critical Power Determined From a 3-Min All-Out Test, Respiratory Compensation Point, Gas Exchange Threshold, and Ventilatory Threshold
Purpose: Critical power (CP) from the 3-min test was compared to the power outputs associated with thresholds determined from gas exchange parameters that have been used to demarcate the exercise-intensity domains including the respiratory compensation point (RCP), gas exchange threshold (GET), and ventilatory threshold (VT). Method: Twenty-eight participants performed an incremental-cycle ergometer test to exhaustion. The VT was determined from the relationship between the ventilatory equivalent for oxygen uptake (V˙E/V˙O2) versus V˙O2 and the GET was determined using the V-slope method (V˙CO2 vs. V˙O2). The RCP was identified from the V˙E-versus-V˙CO2 relationship. CP was the average power output during the last 30 s of the 3-min all-out test. Linear regression was used to determine the power outputs associated with the RCP, GET, and VT, as well as the V˙O2 associated with CP. Mean differences among the associated power outputs, percent V˙O2 peak, and percent peak power output for the GET, VT, RCP, and CP were analyzed using separate one-way repeated-measures analyses of variance. Results: There were no significant differences between CP (187 ± 47 W) and the power output associated with RCP (190 ± 49 W) or between the power outputs associated with GET (139 ± 37 W) and VT (145 ± 37 W). The power outputs associated with GET and VT, however, were significantly less than were those at CP and associated with RCP. Conclusions: These findings suggest CP and RCP demarcate the heavy from severe exercise-intensity domain and result from a different mechanism of fatigue than that of GET and VT, possibly hyperkalemia.
- 1 April 2013
- Published by Elsevier in Journal of Electromyography and Kinesiology
- Vol. 23 (2) , 349-355
Mechanomyographic and metabolic responses during continuous cycle ergometry at critical power from the 3-min all-out test
- 1 April 2013
- Published by Elsevier in Journal of Electromyography and Kinesiology
- Vol. 23 (2) , 349-355
Mechanomyographic and metabolic responses during continuous cycle ergometry at critical power from the 3-min all-out test
- 1 March 2013
- Published by Taylor & Francis in Journal of Sports Sciences
- Vol. 31 (5) , 537-545
Responses during exhaustive exercise at critical power determined from the 3-min all-out test
The purpose of the present study was to examine oxygen consumption rate ([Vdot] ), heart rate (HR), and ratings of perceived exertion (RPE) responses, as well as time to exhaustion (Tlim) values during continuous rides at critical power (CP) determined from the 3-min all-out test. Eighteen participants (mean ± s: 23.6 ± 3.5 years; 72.7 ± 18.2 kg) performed an incremental cycle ergometer test to exhaustion to determine peak oxygen consumption rate ([Vdot] peak) and HR peak. Critical power was determined from the 3-min all-out test. Metabolic responses ([Vdot] and heart rate), RPE, and Tlim were recorded during continuous rides to exhaustion at CP. Linear regression and t-tests were used to compare [Vdot] , heart rate, and RPE responses during the continuous rides to exhaustion. The Tlim at CP was 12.5 ± 6.5 min. There were significant increases in [Vdot] , HR, and RPE during the continuous rides at CP and 15 of the 18 participants reached [Vdot] peak at exhaustion. Therefore, the [Vdot] , heart rate, and RPE responses, as well as the Tlim values in the present study suggested that CP determined from the 3-min all-out test overestimated the “true” CP and was within the severe exercise intensity domain.
- 1 March 2013
- Published by Taylor & Francis in Journal of Sports Sciences
- Vol. 31 (5) , 537-545
Responses during exhaustive exercise at critical power determined from the 3-min all-out test
The purpose of the present study was to examine oxygen consumption rate ([Vdot] ), heart rate (HR), and ratings of perceived exertion (RPE) responses, as well as time to exhaustion (Tlim) values during continuous rides at critical power (CP) determined from the 3-min all-out test. Eighteen participants (mean ± s: 23.6 ± 3.5 years; 72.7 ± 18.2 kg) performed an incremental cycle ergometer test to exhaustion to determine peak oxygen consumption rate ([Vdot] peak) and HR peak. Critical power was determined from the 3-min all-out test. Metabolic responses ([Vdot] and heart rate), RPE, and Tlim were recorded during continuous rides to exhaustion at CP. Linear regression and t-tests were used to compare [Vdot] , heart rate, and RPE responses during the continuous rides to exhaustion. The Tlim at CP was 12.5 ± 6.5 min. There were significant increases in [Vdot] , HR, and RPE during the continuous rides at CP and 15 of the 18 participants reached [Vdot] peak at exhaustion. Therefore, the [Vdot] , heart rate, and RPE responses, as well as the Tlim values in the present study suggested that CP determined from the 3-min all-out test overestimated the “true” CP and was within the severe exercise intensity domain.
- 1 January 2013
- Published by Canadian Science Publishing in Applied Physiology, Nutrition, and Metabolism
- Vol. 38 (1) , 7-13
Metabolic and neuromuscular responses at critical power from the 3-min all-out test
The purpose of this study was to determine the specific metabolic and neuromuscular responses at critical power (CP) from the 3-min all-out test. Nine men (mean ± SD: aged 23.7 ± 3.3 years) performed an incremental test for the determination of peak oxygen consumption (V̇O2peak) and gas exchange threshold. CP was estimated for each subject from the 3-min all-out test. Oxygen consumption (V̇O2), the ventilation versus carbon dioxide production ratio (V̇E/V̇CO2 ratio), electromyographic (EMG) amplitude, and EMG mean power frequency (MPF) were examined during exhaustive rides at CP for each subject. There was no significant difference between the V̇O2 at exhaustion (40.6 ± 7.5 mL·kg−1·min−1) and V̇O2peak (42.9 ± 7.3 mL·kg−1·min−1). Furthermore, there were significant increases in EMG amplitude and the V̇E/V̇CO2 ratio during the exhaustive rides at CP. There was, however, no significant change in EMG MPF over time. Therefore, the current findings indicated that the 3-min all-out test overestimated CP and the demarcation between the heavy- and severe-intensity domains. Specifically, the V̇O2, ventilatory, and EMG amplitude responses were consistent with those observed during continuous exercise in the severe exercise intensity domain. It is likely that the ventilatory and EMG amplitude responses were associated with a common mechanism of fatigue that is different from what affects EMG MPF.
- 1 January 2013
- Published by Canadian Science Publishing in Applied Physiology, Nutrition, and Metabolism
- Vol. 38 (1) , 7-13
Metabolic and neuromuscular responses at critical power from the 3-min all-out test
The purpose of this study was to determine the specific metabolic and neuromuscular responses at critical power (CP) from the 3-min all-out test. Nine men (mean ± SD: aged 23.7 ± 3.3 years) performed an incremental test for the determination of peak oxygen consumption (V̇O2peak) and gas exchange threshold. CP was estimated for each subject from the 3-min all-out test. Oxygen consumption (V̇O2), the ventilation versus carbon dioxide production ratio (V̇E/V̇CO2 ratio), electromyographic (EMG) amplitude, and EMG mean power frequency (MPF) were examined during exhaustive rides at CP for each subject. There was no significant difference between the V̇O2 at exhaustion (40.6 ± 7.5 mL·kg−1·min−1) and V̇O2peak (42.9 ± 7.3 mL·kg−1·min−1). Furthermore, there were significant increases in EMG amplitude and the V̇E/V̇CO2 ratio during the exhaustive rides at CP. There was, however, no significant change in EMG MPF over time. Therefore, the current findings indicated that the 3-min all-out test overestimated CP and the demarcation between the heavy- and severe-intensity domains. Specifically, the V̇O2, ventilatory, and EMG amplitude responses were consistent with those observed during continuous exercise in the severe exercise intensity domain. It is likely that the ventilatory and EMG amplitude responses were associated with a common mechanism of fatigue that is different from what affects EMG MPF.
- 1 October 2012
- Published by Canadian Science Publishing in Applied Physiology, Nutrition, and Metabolism
- Vol. 37 (5) , 872-879
Estimated times to exhaustion and power outputs at the gas exchange threshold, physical working capacity at the rating of perceived exertion threshold, and respiratory compensation point
The purposes of this study were to compare the power outputs and estimated times to exhaustion (Tlim) at the gas exchange threshold (GET), physical working capacity at the rating of perceived exertion threshold (PWCRPE), and respiratory compensation point (RCP). Three male and 5 female subjects (mean ± SD: age, 22.4 ± 2.8 years) performed an incremental test to exhaustion on an electronically braked cycle ergometer to determine peak oxygen consumption rate, GET, and RCP. The PWCRPEwas determined from ratings of perceived exertion data recorded during 3 continuous workbouts to exhaustion. The estimated Tlimvalues for each subject at GET, PWCRPE, and RCP were determined from power curve analyses (Tlim = axb). The results indicated that the PWCRPE(176 ± 55 W) was not significantly different from RCP (181 ± 54 W); however, GET (155 ± 42 W) was significantly less than PWCRPEand RCP. The estimated Tlimfor the GET (26.1 ± 9.8 min) was significantly greater than PWCRPE(14.6 ± 5.6 min) and RCP (11.2 ± 3.1 min). The PWCRPEoccurred at a mean power output that was 13.5% greater than the GET and, therefore, it is likely that the perception of effort is not driven by the same mechanism that underlies the GET (i.e., lactate buffering). Furthermore, the PWCRPEand RCP were not significantly different and, therefore, these thresholds may be associated with the same mechanisms of fatigue, such as increased levels of interstitial and (or) arterial [K+].
- 1 October 2012
- Published by Canadian Science Publishing in Applied Physiology, Nutrition, and Metabolism
- Vol. 37 (5) , 872-879
Estimated times to exhaustion and power outputs at the gas exchange threshold, physical working capacity at the rating of perceived exertion threshold, and respiratory compensation point
The purposes of this study were to compare the power outputs and estimated times to exhaustion (Tlim) at the gas exchange threshold (GET), physical working capacity at the rating of perceived exertion threshold (PWCRPE), and respiratory compensation point (RCP). Three male and 5 female subjects (mean ± SD: age, 22.4 ± 2.8 years) performed an incremental test to exhaustion on an electronically braked cycle ergometer to determine peak oxygen consumption rate, GET, and RCP. The PWCRPEwas determined from ratings of perceived exertion data recorded during 3 continuous workbouts to exhaustion. The estimated Tlimvalues for each subject at GET, PWCRPE, and RCP were determined from power curve analyses (Tlim = axb). The results indicated that the PWCRPE(176 ± 55 W) was not significantly different from RCP (181 ± 54 W); however, GET (155 ± 42 W) was significantly less than PWCRPEand RCP. The estimated Tlimfor the GET (26.1 ± 9.8 min) was significantly greater than PWCRPE(14.6 ± 5.6 min) and RCP (11.2 ± 3.1 min). The PWCRPEoccurred at a mean power output that was 13.5% greater than the GET and, therefore, it is likely that the perception of effort is not driven by the same mechanism that underlies the GET (i.e., lactate buffering). Furthermore, the PWCRPEand RCP were not significantly different and, therefore, these thresholds may be associated with the same mechanisms of fatigue, such as increased levels of interstitial and (or) arterial [K+].
- 1 March 2012
- Published by Wolters Kluwer Health in Journal of Strength & Conditioning Research
- Vol. 26 (3) , 656-663
A New Single Work Bout Test to Estimate Critical Power and Anaerobic Work Capacity
Bergstrom, HC, Housh, TJ, Zuniga, JM, Camic, CL, Traylor, DA, Schmidt, RJ, and Johnson, GO. A new single work bout test to estimate critical power and anaerobic work capacity. J Strength Cond Res 26(3): 656–663, 2012—The purpose of this study was to develop a 3-minute, all-out test protocol using the Monark cycle ergometer for estimating the critical power (CP) and anaerobic work capacity (AWC) with the resistance based on body weight. Twelve moderately trained adults (mean age ± SD = 23.2 ± 3.5 years) performed an incremental cycle ergometer test to exhaustion. The CP and AWC were estimated from the original work limit (Wlim) vs. time limit (Tlim) relationship (CPPT) and a 3-minute all-out test (CP3min) against a fixed resistance and compared with the CP and AWC estimated from the new 3-minute tests on the Monark cycle ergometer (CP3.5% and CP4.5%). The resistance values for the CP3.5% and CP4.5% tests were set at 3.5 and 4.5% of the subject's body weight (kilograms). The results indicated that there were no significant differences (p > 0.05) among mean CP values for CPPT (178 ± 47 W), CP3.5% (173 ± 40 W), and CP4.5% (186 ± 44 W). The mean CP3min (193 ± 54 W), however, was significantly greater than CPPT and CP3.5%. There were no significant differences in AWC for the CPPT (13,412 ± 6,247 J), CP3min (10,895 ± 2,923 J), and CP4.5% (9,842 ± 4,394 J). The AWC values for the CPPT and CP3min, however, were significantly greater than CP3.5% (8,357 ± 2,946 J). The results of this study indicated that CP and AWC could be estimated from a single 3-minute work bout test on the Monark cycle ergometer with the resistance set at 4.5% of the body weight. A single work bout test with the resistance based on the individual's body weight provides a practical and accessible method to estimate CP and AWC.
- 1 March 2012
- Published by Wolters Kluwer Health in Journal of Strength & Conditioning Research
- Vol. 26 (3) , 656-663
A New Single Work Bout Test to Estimate Critical Power and Anaerobic Work Capacity
Bergstrom, HC, Housh, TJ, Zuniga, JM, Camic, CL, Traylor, DA, Schmidt, RJ, and Johnson, GO. A new single work bout test to estimate critical power and anaerobic work capacity. J Strength Cond Res 26(3): 656–663, 2012—The purpose of this study was to develop a 3-minute, all-out test protocol using the Monark cycle ergometer for estimating the critical power (CP) and anaerobic work capacity (AWC) with the resistance based on body weight. Twelve moderately trained adults (mean age ± SD = 23.2 ± 3.5 years) performed an incremental cycle ergometer test to exhaustion. The CP and AWC were estimated from the original work limit (Wlim) vs. time limit (Tlim) relationship (CPPT) and a 3-minute all-out test (CP3min) against a fixed resistance and compared with the CP and AWC estimated from the new 3-minute tests on the Monark cycle ergometer (CP3.5% and CP4.5%). The resistance values for the CP3.5% and CP4.5% tests were set at 3.5 and 4.5% of the subject's body weight (kilograms). The results indicated that there were no significant differences (p > 0.05) among mean CP values for CPPT (178 ± 47 W), CP3.5% (173 ± 40 W), and CP4.5% (186 ± 44 W). The mean CP3min (193 ± 54 W), however, was significantly greater than CPPT and CP3.5%. There were no significant differences in AWC for the CPPT (13,412 ± 6,247 J), CP3min (10,895 ± 2,923 J), and CP4.5% (9,842 ± 4,394 J). The AWC values for the CPPT and CP3min, however, were significantly greater than CP3.5% (8,357 ± 2,946 J). The results of this study indicated that CP and AWC could be estimated from a single 3-minute work bout test on the Monark cycle ergometer with the resistance set at 4.5% of the body weight. A single work bout test with the resistance based on the individual's body weight provides a practical and accessible method to estimate CP and AWC.
- 1 May 2011
- Published by Wolters Kluwer Health in Medicine & Science in Sports & Exercise
- Vol. 43 (5) , 566
Application Of The Dmax Method To Identify The Gas Exchange, Ventilatory, And Neuromuscular Fatigue Thresholds
- 1 May 2011
- Published by Wolters Kluwer Health in Medicine & Science in Sports & Exercise
- Vol. 43 (5) , 566
Application Of The Dmax Method To Identify The Gas Exchange, Ventilatory, And Neuromuscular Fatigue Thresholds