Pupil size measurements with a multifunctional aberrometer/coherence interferometer/tomographer and two infrared-based pupillometers
- 1 June 2024
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 50 (6) , 631-636
Abstract
Purpose: To compare precision of pupil size measurements of a multifunctional device (Pentacam AXL Wave [Pentacam]) and 2 infrared-based pupillometers (PupilX, Colvard) and to compare repeatability of Pentacam and PupilX. Setting: Department of Ophthalmology, Goethe-University, Frankfurt am Main, Germany. Design: Prospective, comparative trial. Methods: Pupil diameter of healthy eyes was measured with Colvard once and Pentacam without glare (WO) and with glare (WG), PupilX in 0, 1, and 16 lux 3 times each. In a second series, measurements with Pentacam WO and PupilX in 0.06 and 0.12 lux were assessed. Results: 36 eyes of participants aged 21 to 63 years were included. Mean pupil diameter was 6.05 mm with Colvard, 5.79 mm (first series), 5.50 mm (second series) with Pentacam WO, 3.42 mm WG, 7.26 mm PupilX in 0, 4.67 mm 1, 3.66 mm 16, 6.82 mm in 0.06, and 6.39 mm in 0.12 lux. Measurements with Pentacam WO were significantly different to PupilX in 0, 0.06, 0.12, and 1 lux (all P < .001), but not to Colvard (P = .086). Pupil size measured with Pentacam WG and PupilX in 16 lux was not significantly different (P = .647). Consecutive measurements with Pentacam WO and WG had mean SD of 0.23 mm and 0.20 mm, respectively, and with PupilX 0.11 in 0, 0.24 mm 1, and 0.20 mm in 16 lux. Conclusions: Pentacam provided good assessment of pupil size but was not equivalent to PupilX in low lighting conditions. Repeatability was more favorable for Pentacam.Keywords
This publication has 29 references indexed in Scilit:
- Automated Pupillometry Using a Prototype Binocular Optical Coherence Tomography SystemAmerican Journal of Ophthalmology, 2020
- Factors for good near and distance visual outcomes of multifocal intraocular lens with inferior segmental near addGraefe's Archive for Clinical and Experimental Ophthalmology, 2020
- The interaction of pupil response with the vergence systemGraefe's Archive for Clinical and Experimental Ophthalmology, 2017
- Effect of Preoperative Pupil Size on Quality of Vision after Wavefront-Guided LASIKOphthalmology, 2011
- Phakic intraocular lensesJournal of Cataract & Refractive Surgery, 2010
- Correlation of infrared pupillometers and CCD-camera imaging from aberrometry and videokeratography for determining scotopic pupil sizeJournal of Cataract & Refractive Surgery, 2004
- Scotopic pupil size in a normal pediatric population using infrared pupillometryGraefe's Archive for Clinical and Experimental Ophthalmology, 2003
- Pupil size and quality of vision after LASIKOphthalmology, 2003
- Comparison of three different technologies for pupil diameter measurementGraefe's Archive for Clinical and Experimental Ophthalmology, 2003
- Agreement and repeatability of infrared pupillometry and the comparison methodOphthalmology, 1999