PDPetra Davidova

Petra Davidova

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Petra Davidova has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Eight-year results of LASIK with or without combined accelerated crosslinking in highly myopic eyes

    by Klemens Paul Kaiser, Jakob Wend, Petra Davidova, Tyll Jandewerth, Zubeida H. Omerovic, Eva Hemkeppler, Christoph Lwowski, Myriam Böhm, Thomas Kohnen

    Purpose: To analyze the 8-year results of femtosecond laser–assisted in situ keratomileusis (LASIK) combined with simultaneous accelerated corneal crosslinking (LASIK-Xtra) compared with conventional LASIK (convLASIK). Setting: Department of Ophthalmology, Goethe-University, Frankfurt am Main, Germany. Design: Prospective, randomized fellow eye–controlled clinical trial. Methods: Patients who received randomized treatment with the LASIK-Xtra (30 mW/cm 2 , 90 seconds with continuous UV-A) in 1 eye and convLASIK in the fellow eye were subjected 1 year (pos1y), and 8 years postoperatively (pos8y) to subjective refraction, uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), endothelial cell count (ECC), biomechanical evaluation, and tomographic examination. Results: 26 eyes (−7.07 ± 1.86 diopter [D]) from 13 patients (mean age 30.7 ± 10.4 years) were included. UDVA and CDVA were insignificantly different at pos1y and pos8y between convLASIK and LASIK-Xtra (each P > .28). The safety index at pos8y was 1.09 for convLASIK and 1.15 for LASIK-Xtra ( P = .799), and the efficacy index 0.91 and 0.94 ( P = .875), respectively. Significant myopic shift in spherical equivalent between pos1y (−0.30 ± 0.40 D) and pos8y (−0.80 ± 0.86 D) was found in the convLASIK group ( P = .018), compared the LASIK-Xtra group (−0.25 ± 0.49 D and −0.40 ± 0.86 D; P = .261), respectively. However, these refractive changes cannot be fully attributed to corneal alterations alone and may also reflect other factors. Insignificant differences in mean keratometry, corneal thickness, and ECC were found at pos8y ( P > .05). The stress–strain index was the only biomechanical parameter that was significantly higher in the LASIK-Xtra group at pos8y ( P = .034). Conclusions: After 8 years, no substantial disparities in efficacy and safety indices were observed between the 2 groups. There were no substantial differences in most of the evaluated postoperative corneal biomechanical parameters between the 2 groups. However, these findings need to be validated by further studies with larger sample sizes.


  • Surgical implications in intraocular lens exchange with an open posterior capsule: a retrospective case series and review of the literature

    by Klemens Paul Kaiser, Tyll Jandewerth, Petra Davidova, Thomas Kohnen

    Purpose: To determine characteristics and differences in intraocular lens (IOL) exchange between eyes with an open (OPC) and closed posterior capsule (CPC). Setting: Department of Ophthalmology, Goethe-University, Frankfurt, Germany. Design: Retrospective case series and review of literature. Methods: Charts of all cases of IOL exchange between January 2010 and May 2024 were retrospectively reviewed. Main outcome measures were indications for surgery, IOL implantation technique, and the necessity of anterior vitrectomy. MEDLINE database and Google scholar were used to identify relevant past publications. Results: We included 37 eyes of 30 patients with a mean age of 62.1 ± 10.2 years, with 16 eyes (43.2%) with OPC undergoing IOL exchange. Mean interval between IOL implantation and IOL exchange was 61.50 ± 62.00 months in the OPC group and 15.81 ± 15.03 months in the CPC group. The most common indication was optical phenomena in 18 cases (48%). In the OPC group, intraoperative anterior vitrectomy was necessary twice as often (OPC nine cases (56%) vs. CPC five cases (24%)). Bag-to-bag IOL exchange was performed in all eyes with CPC, and in 10/16 (62%) with OPC (p=0.009). Postoperative complications were seen in a total of 7/16 eyes (43.7%) with OPC and 3/21 (14.3%) with CPC (p=0.012). Conclusion: The success rate of repositioning an IOL within a bag with OPC is less than that achieved with CPC. A vitrectomy is typically required when attempting a bag-to-bag IOL exchange with an OPC. Capsulotomy should only be performed if the necessity of an IOL exchange is unlikely.


  • Pupil size measurements with a multifunctional aberrometer/coherence interferometer/tomographer and two infrared-based pupillometers

    by Petra Davidova, Marvin Biller, Vanessa Ademmer, Thomas MD Kohnen

    Purpose: To compare precision of pupil size measurements of a multifunctional device (Pentacam AXL Wave [Pentacam]) and 2 infrared-based pupillometers (PupilX, Colvard) and to compare repeatability of Pentacam and PupilX. Setting: Department of Ophthalmology, Goethe-University, Frankfurt am Main, Germany. Design: Prospective, comparative trial. Methods: Pupil diameter of healthy eyes was measured with Colvard once and Pentacam without glare (WO) and with glare (WG), PupilX in 0, 1, and 16 lux 3 times each. In a second series, measurements with Pentacam WO and PupilX in 0.06 and 0.12 lux were assessed. Results: 36 eyes of participants aged 21 to 63 years were included. Mean pupil diameter was 6.05 mm with Colvard, 5.79 mm (first series), 5.50 mm (second series) with Pentacam WO, 3.42 mm WG, 7.26 mm PupilX in 0, 4.67 mm 1, 3.66 mm 16, 6.82 mm in 0.06, and 6.39 mm in 0.12 lux. Measurements with Pentacam WO were significantly different to PupilX in 0, 0.06, 0.12, and 1 lux (all P < .001), but not to Colvard (P = .086). Pupil size measured with Pentacam WG and PupilX in 16 lux was not significantly different (P = .647). Consecutive measurements with Pentacam WO and WG had mean SD of 0.23 mm and 0.20 mm, respectively, and with PupilX 0.11 in 0, 0.24 mm 1, and 0.20 mm in 16 lux. Conclusions: Pentacam provided good assessment of pupil size but was not equivalent to PupilX in low lighting conditions. Repeatability was more favorable for Pentacam.