Precision and accuracy of measuring finger motion with a depth camera: a cross-sectional study of healthy participants
- 24 November 2022
- journal article
- research article
- Published by SAGE Publications in Journal of Hand Surgery (European Volume)
- Vol. 48 (5) , 453-458
Abstract
The purpose of this cross-sectional study was to determine the precision and accuracy of the measurement of finger motion with a depth camera. Fifty-five healthy adult hands were included. Measurements were done with a depth camera and compared with traditional manual goniometer measurements. Repeated measuring showed that the overall repeatability and reproducibility of extension measured with the depth camera were within 3° and 4° and that of flexion were within 13° and 14°. Compared with traditional manual goniometry, biases of extension of all finger joints and flexion of metacarpophalangeal joints were less than 5°, and the average bias of flexion of proximal and distal interphalangeal joints was 29°. We conclude that the measurement of finger extension and flexion of the metacarpophalangeal joints with a depth camera was reliable, but improvement is required in the precision and accuracy of interphalangeal joint flexion.Keywords
This publication has 18 references indexed in Scilit:
- Geometric Deep Learning: Going beyond Euclidean dataIEEE Signal Processing Magazine, 2017
- Usability evaluation of low-cost virtual reality hand and arm rehabilitation gamesJournal of Rehabilitation Research and Development, 2016
- A Non-Contact Measurement System for the Range of Motion of the HandSensors, 2015
- Evaluation of Hand Motion Capture Protocol Using Static Computed Tomography Images: Application to an Instrumented GloveJournal of Biomechanical Engineering, 2014
- Human hand modelling: kinematics, dynamics, applicationsBiological Cybernetics, 2012
- Systematic accuracy and precision analysis of video motion capturing systems—exemplified on the Vicon-460 systemJournal of Biomechanics, 2008
- A Survey of Glove-Based Systems and Their ApplicationsIEEE Transactions on Systems, Man and Cybernetics, Part C (Applications and Reviews), 2008
- A study to compare the reliability of composite finger flexion with goniometry for measurement of range of motion in the handClinical Rehabilitation, 2002
- Digital ranges of motion: Normal values in young adultsThe Journal of Hand Surgery, 1991
- An Experimental Determination of Human Hand Accuracy with a DataGloveProceedings of the Human Factors Society Annual Meeting, 1989