Lulu Lv
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Lulu Lv has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
Fanbin Gu
Department of Microsurgery, Orthopaedic Trauma and Hand Surgery, the First Affiliated Hospital, Sun Yat-sen University, Guangzhou, China
2 shared publicationsJiantao Yang
Department of Microsurgery, Orthopaedic Trauma and Hand Surgery, the First Affiliated Hospital, Sun Yat-sen University, Guangzhou, China
2 shared publicationsJingyuan Fan
Department of Microsurgery, Orthopaedic Trauma and Hand Surgery, the First Affiliated Hospital, Sun Yat-sen University, Guangzhou, China
2 shared publicationsQingtang Zhu
Department of Microsurgery, Orthopaedic Trauma and Hand Surgery, the First Affiliated Hospital, Sun Yat-sen University, Guangzhou, China
2 shared publications- Xiaolin Liu
Department of Microsurgery, Orthopedic Trauma and Hand Surgery, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, China
2 shared publications
Latest Publications
- 24 November 2022
- Published by SAGE Publications in Journal of Hand Surgery (European Volume)
- Vol. 48 (5) , 453-458
Precision and accuracy of measuring finger motion with a depth camera: a cross-sectional study of healthy participants
The purpose of this cross-sectional study was to determine the precision and accuracy of the measurement of finger motion with a depth camera. Fifty-five healthy adult hands were included. Measurements were done with a depth camera and compared with traditional manual goniometer measurements. Repeated measuring showed that the overall repeatability and reproducibility of extension measured with the depth camera were within 3° and 4° and that of flexion were within 13° and 14°. Compared with traditional manual goniometry, biases of extension of all finger joints and flexion of metacarpophalangeal joints were less than 5°, and the average bias of flexion of proximal and distal interphalangeal joints was 29°. We conclude that the measurement of finger extension and flexion of the metacarpophalangeal joints with a depth camera was reliable, but improvement is required in the precision and accuracy of interphalangeal joint flexion.
- 24 November 2022
- Published by SAGE Publications in Journal of Hand Surgery (European Volume)
- Vol. 48 (5) , 453-458
Precision and accuracy of measuring finger motion with a depth camera: a cross-sectional study of healthy participants
The purpose of this cross-sectional study was to determine the precision and accuracy of the measurement of finger motion with a depth camera. Fifty-five healthy adult hands were included. Measurements were done with a depth camera and compared with traditional manual goniometer measurements. Repeated measuring showed that the overall repeatability and reproducibility of extension measured with the depth camera were within 3° and 4° and that of flexion were within 13° and 14°. Compared with traditional manual goniometry, biases of extension of all finger joints and flexion of metacarpophalangeal joints were less than 5°, and the average bias of flexion of proximal and distal interphalangeal joints was 29°. We conclude that the measurement of finger extension and flexion of the metacarpophalangeal joints with a depth camera was reliable, but improvement is required in the precision and accuracy of interphalangeal joint flexion.
- Open Access
- 21 October 2022
- Published by Elsevier in Journal of Hand Surgery Global Online
- Vol. 5 (1) , 39-47
Validity and Reliability of a Depth Camera–Based Quantitative Measurement for Joint Motion of the Hand
- 21 October 2022
- Published by Elsevier in Journal of Hand Surgery Global Online
- Vol. 5 (1) , 39-47
Open AccessValidity and Reliability of a Depth Camera–Based Quantitative Measurement for Joint Motion of the Hand