A platinum oxide-based microvoltammetric pH electrode suitable for physiological investigations
- 30 May 2018
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 143 (13) , 3124-3133
Abstract
Attempts to develop miniaturised pH electrodes for in vivo monitoring have received much attention in recent years. Continuous real-time pH measurements may be predictive of potentially dangerous deviations in metabolic events that could improve patient prognosis. Herein, we report the in vitro investigation of a physiologically relevant, Pt oxide-based microvoltammetric pH electrode. Cycling through the potential window range −0.65 V to +0.8 V vs. SCE, gave rise to well-established monolayer oxide (MO) and hydrogen (H2) adsorption redox peaks in aqueous solution. The H2 desorption and MO reduction peaks demonstrated pH dependent, linear responses (49 ± 11 mV pH−1 and 76 ± 4 mV pH−1 respectively), following pre-activation of the electrode surface in HCl. Since in vivo monitoring is at the core of this design, the effect of incorporating a miniaturised pseudo reference electrode (PRE) was determined. The Ag/AgCl PRE demonstrated near Nernstian behaviour for the MO reduction peak (58 ± 5 mV pH−1) and sub-Nernstian behaviour (43 ± 6 mV pH−1) for its H2 desorption counterpart. Finally, a preliminary in vivo recording performed in the striatum of a freely moving mouse confirmed that the MO reduction peak was maintained under physiological conditions. These findings support the ability of the Pt oxide-based pH electrode to perform continuous, stable recordings in vivo and warrants further characterisation.Keywords
Funding Information
- Enterprise Ireland (EI/CF/2013/3618, EI/CF/2013/3620)
- European Regional Development Fund
This publication has 56 references indexed in Scilit:
- Thirty years of platinum single crystal electrochemistryJournal of Solid State Electrochemistry, 2011
- A Healthy Future: Platinum in Medical ApplicationsPlatinum Metals Review, 2011
- The mechanism of hydrazine electro-oxidation revealed by platinum microelectrodes: role of residual oxidesPhysical Chemistry Chemical Physics, 2011
- Microfabricated Reference Electrodes and their Biosensing ApplicationsSensors, 2010
- Metal Oxides and Ion-Exchanging Surfaces as pH Sensors in Liquids: State-of-the-Art and OutlookSensors, 2009
- Review Paper: Materials and Techniques forIn VivopH MonitoringIEEE Sensors Journal, 2007
- Continuous pH and PCO2 monitoring during respiratory failure in children with the Paratrend 7 inserted into the peripheral venous systemThe Journal of Pediatrics, 2000
- Continuous Monitoring of Arterial Blood Gases and pH during Intraoperative Rapid Blood Administration Using a Paratrend SensorVox Sanguinis, 2000
- Energy Metabolism in Sepsis and InjuryNutrition, 1997
- Corrosion of platinum electrodes in phosphate buffered saline solutionMaterials and Corrosion, 1997