Niall J. Finnerty
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Niall J. Finnerty has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- John Patrick Lowry
Department of Chemistry, Maynooth University, Maynooth, Co. Kildare, Ireland
3 shared publications Caroline H. Reid
Chemistry Department, Maynooth University, Co. Kildare, Ireland
2 shared publications- Caroline H. Reid
Chemistry Department, Maynooth University, Maynooth W23 F2H6, County Kildare, Ireland
2 shared publications Fiachra B. Bolger
Chemistry Department, Maynooth University, Ireland
2 shared publications- Saidhbhe L. O'RIordan
Neurochemistry Research Unit
2 shared publications Andrea M. Wynne
1 shared publication
Latest Publications
- Open Access
- 1 April 2020
- Published by Elsevier in Bioelectrochemistry
- Vol. 132, 107441
An electrochemical investigation into the effects of local and systemic administrations of sodium nitroprusside in brain extracellular fluid of mice
- 1 April 2020
- Published by Elsevier in Bioelectrochemistry
- Vol. 132, 107441
Open AccessAn electrochemical investigation into the effects of local and systemic administrations of sodium nitroprusside in brain extracellular fluid of mice
- 1 November 2018
- Published by Elsevier in Journal of Electroanalytical Chemistry
- Vol. 828, 137-143
The aqueous deposition of a pH sensitive quinone on carbon paste electrodes using linear sweep voltammetry
- 1 November 2018
- Published by Elsevier in Journal of Electroanalytical Chemistry
- Vol. 828, 137-143
The aqueous deposition of a pH sensitive quinone on carbon paste electrodes using linear sweep voltammetry
- 30 May 2018
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 143 (13) , 3124-3133
A platinum oxide-based microvoltammetric pH electrode suitable for physiological investigations
Attempts to develop miniaturised pH electrodes for in vivo monitoring have received much attention in recent years. Continuous real-time pH measurements may be predictive of potentially dangerous deviations in metabolic events that could improve patient prognosis. Herein, we report the in vitro investigation of a physiologically relevant, Pt oxide-based microvoltammetric pH electrode. Cycling through the potential window range −0.65 V to +0.8 V vs. SCE, gave rise to well-established monolayer oxide (MO) and hydrogen (H2) adsorption redox peaks in aqueous solution. The H2 desorption and MO reduction peaks demonstrated pH dependent, linear responses (49 ± 11 mV pH−1 and 76 ± 4 mV pH−1 respectively), following pre-activation of the electrode surface in HCl. Since in vivo monitoring is at the core of this design, the effect of incorporating a miniaturised pseudo reference electrode (PRE) was determined. The Ag/AgCl PRE demonstrated near Nernstian behaviour for the MO reduction peak (58 ± 5 mV pH−1) and sub-Nernstian behaviour (43 ± 6 mV pH−1) for its H2 desorption counterpart. Finally, a preliminary in vivo recording performed in the striatum of a freely moving mouse confirmed that the MO reduction peak was maintained under physiological conditions. These findings support the ability of the Pt oxide-based pH electrode to perform continuous, stable recordings in vivo and warrants further characterisation.
- 30 May 2018
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 143 (13) , 3124-3133
A platinum oxide-based microvoltammetric pH electrode suitable for physiological investigations
Attempts to develop miniaturised pH electrodes for in vivo monitoring have received much attention in recent years. Continuous real-time pH measurements may be predictive of potentially dangerous deviations in metabolic events that could improve patient prognosis. Herein, we report the in vitro investigation of a physiologically relevant, Pt oxide-based microvoltammetric pH electrode. Cycling through the potential window range −0.65 V to +0.8 V vs. SCE, gave rise to well-established monolayer oxide (MO) and hydrogen (H2) adsorption redox peaks in aqueous solution. The H2 desorption and MO reduction peaks demonstrated pH dependent, linear responses (49 ± 11 mV pH−1 and 76 ± 4 mV pH−1 respectively), following pre-activation of the electrode surface in HCl. Since in vivo monitoring is at the core of this design, the effect of incorporating a miniaturised pseudo reference electrode (PRE) was determined. The Ag/AgCl PRE demonstrated near Nernstian behaviour for the MO reduction peak (58 ± 5 mV pH−1) and sub-Nernstian behaviour (43 ± 6 mV pH−1) for its H2 desorption counterpart. Finally, a preliminary in vivo recording performed in the striatum of a freely moving mouse confirmed that the MO reduction peak was maintained under physiological conditions. These findings support the ability of the Pt oxide-based pH electrode to perform continuous, stable recordings in vivo and warrants further characterisation.
- 1 February 2018
- Published by Elsevier in Bioelectrochemistry
- Vol. 119, 124-135
In vitro development and in vivo application of a platinum-based electrochemical device for continuous measurements of peripheral tissue oxygen
- 1 February 2018
- Published by Elsevier in Bioelectrochemistry
- Vol. 119, 124-135
In vitro development and in vivo application of a platinum-based electrochemical device for continuous measurements of peripheral tissue oxygen
- Open Access
Real-Time Amperometric Recording of Extracellular H2O2 in the Brain of Immunocompromised Mice: An In Vitro, Ex Vivo and In Vivo Characterisation Study
We detail an extensive characterisation study on a previously described dual amperometric H2O2 biosensor consisting of H2O2 detection (blank) and degradation (catalase) electrodes. In vitro investigations demonstrated excellent H2O2 sensitivity and selectivity against the interferent, ascorbic acid. Ex vivo studies were performed to mimic physiological conditions prior to in vivo deployment. Exposure to brain tissue homogenate identified reliable sensitivity and selectivity recordings up to seven days for both blank and catalase electrodes. Furthermore, there was no compromise in pre- and post-implanted catalase electrode sensitivity in ex vivo mouse brain. In vivo investigations performed in anaesthetised mice confirmed the ability of the H2O2 biosensor to detect increases in amperometric current following locally perfused/infused H2O2 and antioxidant inhibitors mercaptosuccinic acid and sodium azide. Subsequent recordings in freely moving mice identified negligible effects of control saline and sodium ascorbate interference injections on amperometric H2O2 current. Furthermore, the stability of the amperometric current was confirmed over a five-day period and analysis of 24-h signal recordings identified the absence of diurnal variations in amperometric current. Collectively, these findings confirm the biosensor current responds in vivo to increasing exogenous and endogenous H2O2 and tentatively supports measurement of H2O2 dynamics in freely moving NOD SCID mice.
Open AccessReal-Time Amperometric Recording of Extracellular H2O2 in the Brain of Immunocompromised Mice: An In Vitro, Ex Vivo and In Vivo Characterisation Study
We detail an extensive characterisation study on a previously described dual amperometric H2O2 biosensor consisting of H2O2 detection (blank) and degradation (catalase) electrodes. In vitro investigations demonstrated excellent H2O2 sensitivity and selectivity against the interferent, ascorbic acid. Ex vivo studies were performed to mimic physiological conditions prior to in vivo deployment. Exposure to brain tissue homogenate identified reliable sensitivity and selectivity recordings up to seven days for both blank and catalase electrodes. Furthermore, there was no compromise in pre- and post-implanted catalase electrode sensitivity in ex vivo mouse brain. In vivo investigations performed in anaesthetised mice confirmed the ability of the H2O2 biosensor to detect increases in amperometric current following locally perfused/infused H2O2 and antioxidant inhibitors mercaptosuccinic acid and sodium azide. Subsequent recordings in freely moving mice identified negligible effects of control saline and sodium ascorbate interference injections on amperometric H2O2 current. Furthermore, the stability of the amperometric current was confirmed over a five-day period and analysis of 24-h signal recordings identified the absence of diurnal variations in amperometric current. Collectively, these findings confirm the biosensor current responds in vivo to increasing exogenous and endogenous H2O2 and tentatively supports measurement of H2O2 dynamics in freely moving NOD SCID mice.
- Open Access
Long Term Amperometric Recordings in the Brain Extracellular Fluid of Freely Moving Immunocompromised NOD SCID Mice
We describe the in vivo characterization of microamperometric sensors for the real-time monitoring of nitric oxide (NO) and oxygen (O2) in the striatum of immunocompromised NOD SCID mice. The latter strain has been utilized routinely in the establishment of humanized models of disease e.g., Parkinson’s disease. NOD SCID mice were implanted with highly sensitive and selective NO and O2 sensors that have been previously characterized both in vitro and in freely moving rats. Animals were systemically administered compounds that perturbed the amperometric current and confirmed sensor performance. Furthermore, the stability of the amperometric current was investigated and 24 h recordings examined. Saline injections caused transient changes in both currents that were not significant from baseline. l-NAME caused significant decreases in NO (p < 0.05) and O2 (p < 0.001) currents compared to saline. l-Arginine produced a significant increase (p < 0.001) in NO current, and chloral hydrate and Diamox (acetazolamide) caused significant increases in O2 signal (p < 0.01) compared against saline. The stability of both currents were confirmed over an eight-day period and analysis of 24-h recordings identified diurnal variations in both signals. These findings confirm the efficacy of the amperometric sensors to perform continuous and reliable recordings in immunocompromised mice.
Open AccessLong Term Amperometric Recordings in the Brain Extracellular Fluid of Freely Moving Immunocompromised NOD SCID Mice
We describe the in vivo characterization of microamperometric sensors for the real-time monitoring of nitric oxide (NO) and oxygen (O2) in the striatum of immunocompromised NOD SCID mice. The latter strain has been utilized routinely in the establishment of humanized models of disease e.g., Parkinson’s disease. NOD SCID mice were implanted with highly sensitive and selective NO and O2 sensors that have been previously characterized both in vitro and in freely moving rats. Animals were systemically administered compounds that perturbed the amperometric current and confirmed sensor performance. Furthermore, the stability of the amperometric current was investigated and 24 h recordings examined. Saline injections caused transient changes in both currents that were not significant from baseline. l-NAME caused significant decreases in NO (p < 0.05) and O2 (p < 0.001) currents compared to saline. l-Arginine produced a significant increase (p < 0.001) in NO current, and chloral hydrate and Diamox (acetazolamide) caused significant increases in O2 signal (p < 0.01) compared against saline. The stability of both currents were confirmed over an eight-day period and analysis of 24-h recordings identified diurnal variations in both signals. These findings confirm the efficacy of the amperometric sensors to perform continuous and reliable recordings in immunocompromised mice.
- Open Access
- 8 April 2015
- Published by MDPI AG in Chemosensors
- Vol. 3 (2) , 55-69
Ascorbic Acid Rejection Characteristics of Modified Platinum Electrodes: A Shelf Life Investigation
Ascorbic acid (AA) is the principle interferent present in brain extracellular fluid that can inhibit the ability of electrochemical sensors to selectively detect a particular analyte of interest. Considerable efforts have been made in recent times to develop highly selective membrane coatings to counteract the drawbacks associated with AA interference during in vivo monitoring. The primary objective of the work described within was to investigate the long term effect of storing such selective membranes, i.e., Nafion® and Poly-o-phenylenediamine (PPD) under different conditions and how exposing them to repeated calibration protocols compromises the membranes ability to reject AA. Four different modified platinum (Pt) electrodes, Pt-PPD, Pt-Nafion® (5/2), Pt-Nafion® (1/2)-PPD, and Pt-Nafion® (2/1)-PPD, stored at 4 °C demonstrated deterioration of the polymers integrity when exposed to repeated calibrations. On the contrary, exposing the same four electrode types to single calibrations confirmed excellent retention of AA rejection characteristics. Pt-PPD electrodes were then exposed to varying storage conditions and calibrated against AA on day 1, day 56 and day 168. Storing the Pt-PPD electrodes at 4 °C/N2 saturated glass container demonstrated retention of AA rejection characteristics after day 168. These results have clearly elucidated the optimum storage conditions for Pt-Nafion® and Pt-PPD modified electrodes.
- 8 April 2015
- Published by MDPI AG in Chemosensors
- Vol. 3 (2) , 55-69
Open AccessAscorbic Acid Rejection Characteristics of Modified Platinum Electrodes: A Shelf Life Investigation
Ascorbic acid (AA) is the principle interferent present in brain extracellular fluid that can inhibit the ability of electrochemical sensors to selectively detect a particular analyte of interest. Considerable efforts have been made in recent times to develop highly selective membrane coatings to counteract the drawbacks associated with AA interference during in vivo monitoring. The primary objective of the work described within was to investigate the long term effect of storing such selective membranes, i.e., Nafion® and Poly-o-phenylenediamine (PPD) under different conditions and how exposing them to repeated calibration protocols compromises the membranes ability to reject AA. Four different modified platinum (Pt) electrodes, Pt-PPD, Pt-Nafion® (5/2), Pt-Nafion® (1/2)-PPD, and Pt-Nafion® (2/1)-PPD, stored at 4 °C demonstrated deterioration of the polymers integrity when exposed to repeated calibrations. On the contrary, exposing the same four electrode types to single calibrations confirmed excellent retention of AA rejection characteristics. Pt-PPD electrodes were then exposed to varying storage conditions and calibrated against AA on day 1, day 56 and day 168. Storing the Pt-PPD electrodes at 4 °C/N2 saturated glass container demonstrated retention of AA rejection characteristics after day 168. These results have clearly elucidated the optimum storage conditions for Pt-Nafion® and Pt-PPD modified electrodes.
- 1 October 2014
- Published by Elsevier in Journal of Electroanalytical Chemistry
- Vol. 732, 110-116
In vitro characterisation of ortho phenylenediamine and Nafion®-modified Pt electrodes for measuring brain nitric oxide
- 1 October 2014
- Published by Elsevier in Journal of Electroanalytical Chemistry
- Vol. 732, 110-116
In vitro characterisation of ortho phenylenediamine and Nafion®-modified Pt electrodes for measuring brain nitric oxide
- 1 January 2013
- Published by SAGE Publications in Journal of Parkinson’s Disease
- Vol. 3 (3) , 351-362
Continuous Real-Time in vivo Measurement of Cerebral Nitric Oxide Supports Theoretical Predictions of an Irreversible Switching in Cerebral ROS after Sufficient Exposure to External Toxins
Background: Mathematical models of the interactions between alphasynuclein (αS) and reactive oxygen species (ROS) predict a systematic and irreversible switching to damagingly high levels of ROS after sufficient exposure to risk factors associated with Parkinson's disease (PD). Objectives: We tested this prediction by continuously monitoring real-time changes in neurochemical levels over periods of several days in animals exposed to a toxin known to cause Parkinsonian symptoms. Methods: Nitric oxide (NO) sensors were implanted in the brains of freely moving rats and the NO levels continuously recorded while the animals were exposed to paraquat (PQ) injections of various amounts and frequencies. Results: Long-term, real-time measurement of NO in a cohort of animals showed systematic switching in levels when PQ injections of sufficient size and frequency were administered. The experimental observations of changes in NO imply a corresponding switching in endogenous ROS levels and support theoretical predictions of an irreversible change to damagingly high levels of endogenous ROS when PD risks are sufficiently large. Conclusions: Our current results only consider one form of PD risk, however, we are sufficiently confident in them to conclude that: (i) continuous long-term measurement of neurochemical dynamics provide a novel way to measure the temporal change and system dynamics which determine Parkinsonian damage, and (ii) the bistable feedback switching predicted by mathematical modelling seems to exist and that a deeper analysis of its characteristics would provide a way of understanding the pathogenic mechanisms that initiate Parkinsonian cell damage.
- 1 January 2013
- Published by SAGE Publications in Journal of Parkinson’s Disease
- Vol. 3 (3) , 351-362
Continuous Real-Time in vivo Measurement of Cerebral Nitric Oxide Supports Theoretical Predictions of an Irreversible Switching in Cerebral ROS after Sufficient Exposure to External Toxins
Background: Mathematical models of the interactions between alphasynuclein (αS) and reactive oxygen species (ROS) predict a systematic and irreversible switching to damagingly high levels of ROS after sufficient exposure to risk factors associated with Parkinson's disease (PD). Objectives: We tested this prediction by continuously monitoring real-time changes in neurochemical levels over periods of several days in animals exposed to a toxin known to cause Parkinsonian symptoms. Methods: Nitric oxide (NO) sensors were implanted in the brains of freely moving rats and the NO levels continuously recorded while the animals were exposed to paraquat (PQ) injections of various amounts and frequencies. Results: Long-term, real-time measurement of NO in a cohort of animals showed systematic switching in levels when PQ injections of sufficient size and frequency were administered. The experimental observations of changes in NO imply a corresponding switching in endogenous ROS levels and support theoretical predictions of an irreversible change to damagingly high levels of endogenous ROS when PD risks are sufficiently large. Conclusions: Our current results only consider one form of PD risk, however, we are sufficiently confident in them to conclude that: (i) continuous long-term measurement of neurochemical dynamics provide a novel way to measure the temporal change and system dynamics which determine Parkinsonian damage, and (ii) the bistable feedback switching predicted by mathematical modelling seems to exist and that a deeper analysis of its characteristics would provide a way of understanding the pathogenic mechanisms that initiate Parkinsonian cell damage.
- 1 July 2012
- Published by Elsevier in Journal of Neuroscience Methods
- Vol. 209 (1) , 13-21
Brain nitric oxide: Regional characterisation of a real-time microelectrochemical sensor
- 1 July 2012
- Published by Elsevier in Journal of Neuroscience Methods
- Vol. 209 (1) , 13-21