Ultrastable Laser Wavelength Locking Technique Optimized for WMS-Based Methane Detection
- 24 February 2023
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (7) , 6757-6768
Abstract
Fixed wavelength modulation spectroscopy (FWMS) featured as that wavelength is modulated around a constant value instead of a dynamic scanning ramp in the standard wavelength modulation spectroscopy (WMS). To eliminate the influence of center wavelength drift on absorption measurement in the FWMS system, a software-based proportional integral derivative (PID) controller is developed to lock the laser wavelength at methane line 1653.72 nm for CH 4 detection in this study. Moreover, two crucial parameters of PID, gain and integral time are optimized to improve the laser wavelength locking performance. As a result, the laser wavelength is locked to the target CH 4 line with a 1σ fluctuation less than 406 kHz (better than 3.7×10 -3 pm) with a robust 100% locking success rate, which is the best result reported so far to our knowledge. Based on the wavelength locked FWMS CH 4 sensor, linearity is tested to be R 2 = 0.998 in low concentration range of 0-1000 ppm. Detection sensitivity is 52 ppb at 0.1 s and could be improved to 36 ppb if the integration time is extended to 1.4 s. Compared with standard WMS, CH 4 detection stability is improved by 5 times.Keywords
Funding Information
- National Natural Science Foundation of China (52001295, 62005267)
- Natural Science Foundation of Shandong Province (ZR2020QF097, ZR2021QD140)
- Open Fund of State Key Laboratory of Applied Optics (SKLAO2021001A12)
- Fundamental Research Funds for the Central Universities (202013024, 202065004)
- Shandong Postdoctoral Innovation Program, Key Research and Development Program of Shandong Province (2020CXGC010706)
This publication has 49 references indexed in Scilit:
- Compact TDLAS based optical sensor for ppb-level ethane detection by use of a 3.34 μm room-temperature CW interband cascade laserSensors and Actuators B: Chemical, 2016
- Highly sensitive detection of methane by near-infrared laser absorption spectroscopy using a compact dense-pattern multipass cellSensors and Actuators B: Chemical, 2015
- Single-QCL-based absorption sensor for simultaneous trace-gas detection of CH4 and N2OApplied Physics B, 2014
- A compact QCL based methane and nitrous oxide sensor for environmental and medical applicationsThe Analyst, 2014
- CW DFB RT diode laser-based sensor for trace-gas detection of ethane using a novel compact multipass gas absorption cellApplied Physics B, 2013
- Carbon dioxide sensors for intelligent food packaging applicationsFood Control, 2012
- Absorption sensor for CO in combustion gases using 2.3 µm tunable diode lasersMeasurement Science and Technology, 2009
- In situ combustion measurements of CO, CO2, H2O and temperature using diode laser absorption sensorsProceedings of the Combustion Institute, 2000
- A novel distributed feedback laser diode structure for an optical wavelength tunable filterSemiconductor Science and Technology, 1997
- HIGH-RESOLUTION INFRARED SPECTROSCOPY WITH A TUNABLE DIODE LASERApplied Physics Letters, 1970