Yaopeng Cheng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yaopeng Cheng has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Fupeng Wang
Faculty of Information Science and Engineering, Ocean University of China, Qingdao, China
1 shared publication - Jiachen Sun
State Key Laboratory of Explosion Science and Safety Protection
1 shared publication Jinghua Wu
Faculty of Information Science and Engineering, Ocean University of China, Qingdao, China
1 shared publication- Qian Li
Faculty of Information Science and Engineering, the Engineering Research Center of Advanced Marine Physical Instruments and Equipment (Ministry of Education), and Qingdao Key Laboratory of Optics and Optoelectronics, Ocean University of China, Qingdao, China
1 shared publication - Qiang Wang
Anhui Institute of Optics and Fine Mechanics, Hefei Institute of Physical Science, Chinese Academy of Sciences, Hefei 230031, China
1 shared publication Qingsheng Xue
Faculty of Information Science and Engineering, Ocean University of China, Qingdao, China
1 shared publication
Latest Publications
- 24 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (7) , 6757-6768
Ultrastable Laser Wavelength Locking Technique Optimized for WMS-Based Methane Detection
Fixed wavelength modulation spectroscopy (FWMS) featured as that wavelength is modulated around a constant value instead of a dynamic scanning ramp in the standard wavelength modulation spectroscopy (WMS). To eliminate the influence of center wavelength drift on absorption measurement in the FWMS system, a software-based proportional integral derivative (PID) controller is developed to lock the laser wavelength at methane line 1653.72 nm for CH 4 detection in this study. Moreover, two crucial parameters of PID, gain and integral time are optimized to improve the laser wavelength locking performance. As a result, the laser wavelength is locked to the target CH 4 line with a 1σ fluctuation less than 406 kHz (better than 3.7×10 -3 pm) with a robust 100% locking success rate, which is the best result reported so far to our knowledge. Based on the wavelength locked FWMS CH 4 sensor, linearity is tested to be R 2 = 0.998 in low concentration range of 0-1000 ppm. Detection sensitivity is 52 ppb at 0.1 s and could be improved to 36 ppb if the integration time is extended to 1.4 s. Compared with standard WMS, CH 4 detection stability is improved by 5 times.
- 24 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (7) , 6757-6768
Ultrastable Laser Wavelength Locking Technique Optimized for WMS-Based Methane Detection
Fixed wavelength modulation spectroscopy (FWMS) featured as that wavelength is modulated around a constant value instead of a dynamic scanning ramp in the standard wavelength modulation spectroscopy (WMS). To eliminate the influence of center wavelength drift on absorption measurement in the FWMS system, a software-based proportional integral derivative (PID) controller is developed to lock the laser wavelength at methane line 1653.72 nm for CH 4 detection in this study. Moreover, two crucial parameters of PID, gain and integral time are optimized to improve the laser wavelength locking performance. As a result, the laser wavelength is locked to the target CH 4 line with a 1σ fluctuation less than 406 kHz (better than 3.7×10 -3 pm) with a robust 100% locking success rate, which is the best result reported so far to our knowledge. Based on the wavelength locked FWMS CH 4 sensor, linearity is tested to be R 2 = 0.998 in low concentration range of 0-1000 ppm. Detection sensitivity is 52 ppb at 0.1 s and could be improved to 36 ppb if the integration time is extended to 1.4 s. Compared with standard WMS, CH 4 detection stability is improved by 5 times.