Purpose: To compare a new optical biometer device, Galilei G6 (Ziemer, Port, Switzerland), with the present optical biometer, Lenstar LS 900 (Haag‐Streit, Koeniz, Switzerland), for intraocular lens (IOL) power calculation. Methods: One hundred forty eyes of 140 cataract patients were evaluated with two optical biometers: the Galilei G6 and the Lenstar. The mean keratometry (K), axial length (AL), anterior chamber depth (ACD), crystalline lens thickness (LT), white‐to‐white (WTW), and IOL powers using the SRK/T, Holladay 1, Hoffer Q, and Haigis formulas were compared. The intrasession repeatability of the Galilei G6 measurements was assessed in 25 eyes. Results: All ocular parameters measured by the Galilei G6 were highly repeatable (all intraclass correlation coefficients > 0.980). Although K and ACD did not show statistical differences between the two devices (all p > 0.05), the measurements for AL, LT, and WTW were statistically different for the two devices. The K, AL, ACD, LT, and WTW showed good correlations (r = 0.975, 0.998, 0.973, 0.946, and 0.710, respectively; all p < 0.001); however, the agreements of LT and WTW were not good between the two devices. The IOL powers using four formulas did not show statistical differences (all p > 0.05); however, agreements between the IOL powers were not strong. The ranges of 95% limit of agreements were between 1.54 and 1.90D according to the formulas. Conclusions: The ocular parameters and IOL powers using the Galilei G6 cannot be used interchangeably with those of the Lenstar in clinical practice.Keywords
This publication has 26 references indexed in Scilit:
- Evaluation of a new optical biometry device for measurements of ocular components and its comparison with IOLMasterBritish Journal of Ophthalmology, 2014
- Comparison of ocular biometry and intraocular lens power using a new biometer and a standard biometerJournal of Cataract & Refractive Surgery, 2014
- Biometry and intraocular lens power calculation results with a new optical biometry device: Comparison with the gold standardJournal of Cataract & Refractive Surgery, 2014
- Agreement analysis of LENSTAR with other techniques of biometryEye, 2011
- Evaluation of 2 new optical biometry devices and comparison with the current gold standard biometerJournal of Cataract & Refractive Surgery, 2011
- Performance of three biometry devices in patients with different grades of age‐related cataractActa Ophthalmologica, 2011
- Comparison of 2 laser instruments for measuring axial lengthJournal of Cataract & Refractive Surgery, 2010
- Intraocular lens power calculation: Clinical comparison of 2 optical biometry devicesJournal of Cataract & Refractive Surgery, 2010
- Accuracy of a new partial coherence interferometry analyser for biometric measurementsBritish Journal of Ophthalmology, 2009
- Prediction of the effective postoperative (intraocular lens) anterior chamber depthJournal of Cataract & Refractive Surgery, 2006