Heterogeneous Versus Homogeneous Radiation Dose Calculations of Twice-Daily Fractionation in Small Cell Lung Carcinoma
Open Access
- 7 December 2021
- journal article
- research article
- Published by Springer Nature in Cureus
- Vol. 13 (12) , e20226
Abstract
The standard radiotherapy regimen for small cell lung cancer (SCLC) was determined using dose calculations without corrections for tissue heterogeneity, while modern treatments are planned using algorithms accounting for tissue heterogeneity. We assessed differences in dose delivered using heterogeneous and homogeneous dose calculations in a cohort of patients treated for limited-stage small cell lung cancer (LS-SCLC). This is a retrospective analysis of 35 patients (three-dimensional conformal radiation therapy (3D-CRT), n = 22; intensity-modulated radiation therapy (IMRT), n = 13) with LS-SCLC treated with chemoradiotherapy from 2011 to 2017. Treatment plans were developed in the Eclipse Treatment Planning System (TPS) version 13.6 using the Analytical Anisotropic Algorithm (AAA). Two plans were generated for each patient with one using the unit relative electron density and the other maintaining the same monitor units (MUs) with tissue density corrections. The prescription was 45 Gy in 30 fractions of 1.5 Gy delivered twice daily. Individuals who underwent replanning within the same treatment course were evaluated using a separate corrected and uncorrected plan sum. Variations greater than 5% in dose to the tumor or organs at risk were considered clinically relevant. A two-sided paired t-test was used to evaluate the statistical significance of the dosimetric differences. The percent dose difference between plans without tissue heterogeneity corrections to those with corrections resulted in an overall median difference of -3% (range: -15.1% to 9.6%; p < 0.01) for the dose covering 95% of the planning target volume (PTV D95) and was -5.6% (range: -17.3% to 5.4%; p < 0.01) for lung volume receiving ≥20 Gy (lung V20). For 3D-CRT, the median difference for the PTV D95 was -0.1% (range: -4.7% to 9.6%; p = 0.62) and the lung V20 was -4.2% (range: -9.4 to 5.4; p < 0.01). For IMRT, the median difference for the PTV D95 was -10.0% (range: -15.1% to -5.3%; p < 0.01) and the lung V20 was -8.9% (range: -17.3 to -3.5; p < 0.01). Traditional planning without tissue heterogeneity corrections results in an overall decrease in the dose delivered to the target compared with those that incorporate tissue heterogeneity corrections. These differences are modest for 3D treatment plans but may result in clinically relevant differences for the IMRT cohort (>5% deviation).Keywords
This publication has 17 references indexed in Scilit:
- Accuracy requirements and uncertainties in radiotherapy: a report of the International Atomic Energy AgencyActa Oncologica, 2016
- Treatment of Small-Cell Lung Cancer: American Society of Clinical Oncology Endorsement of the American College of Chest Physicians GuidelineJournal of Clinical Oncology, 2015
- Multi-institutional retrospective analysis of the inhomogeneity correction for radiation therapy of lung cancer.Journal of Radiation Research, 2011
- Predicting Changes in Dose Distribution to Tumor and Normal Tissue When Correcting for Heterogeneity in Radiotherapy for Lung CancerAmerican Journal of Clinical Oncology, 2007
- Changing Epidemiology of Small-Cell Lung Cancer in the United States Over the Last 30 Years: Analysis of the Surveillance, Epidemiologic, and End Results DatabaseJournal of Clinical Oncology, 2006
- 70 Gy thoracic radiotherapy is feasible concurrent with chemotherapy for limited-stage small-cell lung cancer: analysis of Cancer and Leukemia Group B study 39808International Journal of Radiation Oncology - Biology - Physics (IJROBP), 2004
- Staging small cell lung cancer: Veterans Administration Lung Study Group versus International Association for the Study of Lung Cancer—what limits limited disease?Lung Cancer, 2002
- Twice-Daily Compared with Once-Daily Thoracic Radiotherapy in Limited Small-Cell Lung Cancer Treated Concurrently with Cisplatin and EtoposideNew England Journal of Medicine, 1999
- Bronchogenic carcinoma: radiologic-pathologic correlation.RadioGraphics, 1994
- A Meta-Analysis of Thoracic Radiotherapy for Small-Cell Lung CancerNew England Journal of Medicine, 1992