STSean Tanny

Sean Tanny

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Sean Tanny has a total of 55 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Streamlined data extraction and visualization utilizing third‐party verification software for online adaptive radiation therapy

    by Sean Tanny, Alexander Podgorsak, Nicholas Sperling

    Purpose: Online adaptive radiation therapy (oART) has generated a significant influx of daily treatment planning data. Present oART platforms have leveraged automation for decreased planning times at the expense of end‐user access, making longitudinal oART data assessment time consuming. We have developed modified software that extracts oART data from the secondary calculation software associated with one of the oART platforms. Methods: A Python program was developed to query oART data from a web‐based secondary dose calculation software. Structure, plan, and dosimetric data were collected for all generated oART plans over the course of 3 years. This software stores data in a Pandas dataframe to allow for comparisons and advanced visualization. The software includes some pre‐defined visualization and analysis methods, as well as tools to de‐identify and share cohorts of oART data. Results: Twelve hundred oART sessions were pulled from our secondary dose verification software. Various visualization methods were implemented and are demonstrated in this technical note. This software demonstrated significant time savings in data extraction compared to manual session exports, but does not pull raw DICOM information, such as CT scans, structure sets, or dose files. Conclusion: Our extraction software presents a streamlined way to collect, analyze, and visualize oART data using a dedicated oART platform. Further tools are needed to improve access and analysis of oART data.

  • Open Access

    Clinical Practice-Based Failure Modes and Root Cause Analysis of Cone Beam CT-Guided Online Adaptive Radiotherapy of the Pelvis

    by Dandan Zheng, Michael Cummings, Hong Zhang, Alexander Podgorsak, Fiona Li, Olga Dona Lemus, Matthew Webster, Neil Joyce, Erika Hagenbach, Kevin Bylund, et al.

    Background/Objectives: Cone-beam computed tomography (CBCT)-guided online adaptive radiotherapy (oART) represents a significant advancement in radiation oncology, enabling on-couch plan adaptation to account for daily anatomical changes. While this automation improves precision and workflow efficiency, it also introduces new failure modes (FMs) and workflow irregularities. This study aimed to systematically evaluate the clinical and technical challenges associated with CBCT-guided oART implementation. Methods: We retrospectively analyzed over 1000 CBCT-guided oART sessions for pelvic malignancies performed at our institution. A multidisciplinary team conducted a comprehensive review to identify and classify FMs, followed by root cause analysis (RCA) to evaluate their impact on treatment safety, efficacy, and workflow robustness. Results: In addition to session-terminating FMs, we identified recurring failure modes across three major domains: (1) system-driven issues, such as rigid target localization and software-driven irregularities; (2) patient-driven challenges, including interfractional and intrafractional anatomical variations; and (3) treatment planning and execution failures, including excessive dose hotspots from field-of-view limitations. The system’s closed-loop automation, while streamlining processes, introduced rigid constraints in plan adaptation and fallback plan execution, occasionally leading to unintended dose discrepancies. Conclusions: This study provides a comprehensive clinical practice-based evaluation of CBCT-guided oART, highlighting system-specific failure modes and their implications. Addressing these challenges requires structured quality assurance processes, multidisciplinary collaboration, and continuous workflow refinement. Our findings contribute to the development of safer and more robust adaptive radiotherapy platforms and clinical workflows.


  • Does extending the body contour into air enhance surface dose calculation accuracy?

    by Joshua N. Wancura, Olga M. Dona Lemus, Sean M. Tanny, Jihyung Yoon, Matthew J. Webster, Louis S. Constine, Dandan Zheng

  • Open Access

    Comparative analysis of fetal dose sparing between a C‐arm linac and an O‐ring linac in a SIB‐VMAT sarcoma treatment for a pregnant patient: A technical note and case report

    by Wesley Rivais, Louis Constine, Matthew Pacella, Neil Joyce, Maimuna Nagey, Matthew Webster, Jihyung Yoon, Hyunuk Jung, Sean Tanny, Olga Maria Dona Lemus, et al.

    Purpose: To compare the effect of two linacs designs on fetal dose sparing on a pregnant patient, including estimation of the fetal dose, and the effect of a lead apron.Methods: A patient with a high‐grade sarcoma located in the right knee/lower thigh was prescribed 51 Gy (1.7 Gy/Fx) with a simultaneous‐integrated‐boost (SIB) of 60 Gy to a smaller volume, starting in the 26th gestational week. Volumetric modulated radiation therapy (VMAT) plans with 6MV‐FFF were developed using identical dosimetric constraints on a Varian Truebeam Edge with HD‐MLC and a Varian Halcyon with double‐stacked MLC. Based on patient dimension measurements, an anthropomorphic phantom was constructed using a Rando phantom and saline bags in the patient's Vac‐Lok bag. Phantom measurements were performed using OSLDs and TLDs placed at three different planes, corresponding to the pubis, the umbilicus, and the fundus based on patient measurements and projected gestational age, to estimate the fetal dose. Three experimental scenarios were measured, each with CBCT‐based image guidance for an accurate, reproducible setup: Edge, Halcyon, and Halcyon with a tri‐folded lead apron (0.5 mm × 3 = 1.5 mm Pb) over the phantom abdomen.Results: Plan quality and total MUs are comparable between the Edge and Halcyon plans. The OSLD‐measured whole‐course dose to the pubis, umbilicus, and fundus were 18.8, 13.1, and 11.7 cGy, respectively, on Halcyon, on average 27.8% lower than Edge. The repeatability within either dosimeter was good, although TLD showed systematically lower doses. Importantly, both dosimetry systems showed a lower measured fetal dose for the Halcyon plan compared with the Edge plan. Adding a tri‐folded lead apron over the abdomen did not meaningfully lower the measured dose.Conclusion: In this case study, Halcyon demonstrated a better sparing of out‐of‐field fetal dose compared to TrueBeam Edge. It was shown that lead aprons do not provide additional fetal dose sparing.


  • Open Access

    MU variability in CBCT‐guided online adaptive radiation therapy

    by Sean Tanny, Olga M Dona Lemus, Joshua Wancura, Nicholas Sperling, Matthew Webster, Hyunuk Jung, Yuwei Zhou, Fiona Li, Jihyung Yoon, Alexander Podgorsak, et al.

    Purpose: CBCT‐guided online‐adaptive radiotherapy (oART) systems have been made possible by using artificial intelligence and automation to substantially reduce treatment planning time during on‐couch adaptive sessions. Evaluating plans generated during an adaptive session presents significant challenges to the clinical team as the planning process gets compressed into a shorter window than offline planning. We identified MU variations up to 30% difference between the adaptive plan and the reference plan in several oART sessions that caused the clinical team to question the accuracy of the oART dose calculation. We investigated the cause of MU variation and the overall accuracy of the dose delivered when MU variations appear unnecessarily large.Methods: Dosimetric and adaptive plan data from 604 adaptive sessions of 19 patients undergoing CBCT‐guided oART were collected. The analysis included total MU per fraction, planning target volume (PTV) and organs at risk (OAR) volumes, changes in PTV‐OAR overlap, and DVH curves. Sessions with MU greater than two standard deviations from the mean were reoptimized offline, verified by an independent calculation system, and measured using a detector array.Results: MU variations relative to the reference plan were normally distributed with a mean of −1.0% and a standard deviation of 11.0%. No significant correlation was found between MU variation and anatomic changes. Offline reoptimization did not reliably reproduce either reference or on‐couch total MUs, suggesting that stochastic effects within the oART optimizer are likely causing the variations. Independent dose calculation and detector array measurements resulted in acceptable agreement with the planned dose.Conclusions: MU variations observed between oART plans were not caused by any errors within the oART workflow. Providers should refrain from using MU variability as a way to express their confidence in the treatment planning accuracy. Clinical decisions during on‐couch adaptive sessions should rely on validated secondary dose calculations to ensure optimal plan selection.


  • Open Access

    A comprehensive evaluation of advanced dose calculation algorithms for brain stereotactic radiosurgery

    by Jihyung Yoon, Hyunuk Jung, Sean M. Tanny, Olga Maria Dona Lemus, Michael T. Milano, Sara J. Hardy, Kenneth Y. Usuki, Dandan Zheng

    Purpose: Accurate dose calculation is important in both target and low dose normal tissue regions for brain stereotactic radiosurgery (SRS). In this study, we aim to evaluate the dosimetric accuracy of the two advanced dose calculation algorithms for brain SRS.Methods: Retrospective clinical case study and phantom study were performed. For the clinical study, 138 SRS patient plans (443 targets) were generated using BrainLab Elements Voxel Monte Carlo (VMC). To evaluate the dose calculation accuracy, the plans were exported into Eclipse and recalculated with Acuros XB (AXB) algorithm with identical beam parameters. The calculated dose at the target center (Dref), dose to 95% target volume (D95), and the average dose to target (Dmean) were compared. Also, the distance from the skull was analyzed. For the phantom study, a cylindrical phantom and a head phantom were used, and the delivered dose was measured by an ion chamber and EBT3 film, respectively, at various locations. The measurement was compared with the calculated doses from VMC and AXB.Results: In clinical cases, VMC dose calculations tended to be higher than AXB. It was found that the difference in Dref showed > 5% in some cases for smaller volumes < 0.3 cm3. Dmean and D95 differences were also higher for small targets. No obvious trend was found between the dose difference and the distance from the skull. In phantom studies, VMC dose was also higher than AXB for smaller targets, and VMC showed better agreement with the measurements than AXB for both point dose and high dose spread.Conclusion: The two advanced calculation algorithms were extensively compared. For brain SRS, AXB sometimes calculates a noticeable lower target dose for small targets than VMC, and VMC tends to have a slightly closer agreement with measurements than AXB.


  • Open Access

    Influence of air mapping errors on the dosimetric accuracy of prostate CBCT‐guided online adaptive radiation therapy

    by Olga M. Dona Lemus, Sean Tanny, Michael Cummings, Matthew Webster, Joshua Wancura, Hyunuk Jung, Yuwei Zhou, Jihyung Yoon, Matthew Pacella, Dandan Zheng

    Purpose: CBCT‐guided online adaptive radiotherapy (oART) plans presently utilize daily synthetic CTs (sCT) that are automatically generated using deformable registration algorithms. These algorithms may have poor performance at reproducing variable volumes of gas present during treatment. Therefore, we have analyzed the air mapping error between the daily CBCTs and the corresponding sCT and explored its dosimetric effect on oART plan calculation.Methods: Abdominopelvic air volume was contoured on both the daily CBCT images and the corresponding synthetic images for 207 online adaptive pelvic treatments. Air mapping errors were tracked over all fractions. For two case studies representing worst case scenarios, dosimetric effects of air mapping errors were corrected in the sCT images using the daily CBCT air contours, then recalculating dose. Dose volume histogram statistics and 3D gamma passing rates were used to compare the original and air‐corrected sCT‐based dose calculations.Results: All analyzed patients showed observable air pocket contour differences between the sCT and the CBCT images. The largest air volume difference observed in daily CBCT images for a given patient was 276.3 cc, a difference of more than 386% compared to the sCT. For the two case studies, the largest observed change in DVH metrics was a 2.6% reduction in minimum PTV dose, with all other metrics varying by less than 1.5%. 3D gamma passing rates using 1%/1 mm criteria were above 90% when comparing the uncorrected and corrected dose distributions.Conclusion: Current CBCT‐based oART workflow can lead to inaccuracies in the mapping of abdominopelvic air pockets from daily CBCT to the sCT images used for the optimization and calculation of the adaptive plan. Despite the large observed mapping errors, the dosimetric effects of such differences on the accuracy of the adapted plan dose calculation are unlikely to cause differences greater than 3% for prostate treatments.


  • Open Access

    Heterogeneous Versus Homogeneous Radiation Dose Calculations of Twice-Daily Fractionation in Small Cell Lung Carcinoma

    by Ryan Thibodeau, Hsin K. Li, Sean Tanny, Ajeet Gajra, Jeffrey Bogart

    The standard radiotherapy regimen for small cell lung cancer (SCLC) was determined using dose calculations without corrections for tissue heterogeneity, while modern treatments are planned using algorithms accounting for tissue heterogeneity. We assessed differences in dose delivered using heterogeneous and homogeneous dose calculations in a cohort of patients treated for limited-stage small cell lung cancer (LS-SCLC). This is a retrospective analysis of 35 patients (three-dimensional conformal radiation therapy (3D-CRT), n = 22; intensity-modulated radiation therapy (IMRT), n = 13) with LS-SCLC treated with chemoradiotherapy from 2011 to 2017. Treatment plans were developed in the Eclipse Treatment Planning System (TPS) version 13.6 using the Analytical Anisotropic Algorithm (AAA). Two plans were generated for each patient with one using the unit relative electron density and the other maintaining the same monitor units (MUs) with tissue density corrections. The prescription was 45 Gy in 30 fractions of 1.5 Gy delivered twice daily. Individuals who underwent replanning within the same treatment course were evaluated using a separate corrected and uncorrected plan sum. Variations greater than 5% in dose to the tumor or organs at risk were considered clinically relevant. A two-sided paired t-test was used to evaluate the statistical significance of the dosimetric differences. The percent dose difference between plans without tissue heterogeneity corrections to those with corrections resulted in an overall median difference of -3% (range: -15.1% to 9.6%; p < 0.01) for the dose covering 95% of the planning target volume (PTV D95) and was -5.6% (range: -17.3% to 5.4%; p < 0.01) for lung volume receiving ≥20 Gy (lung V20). For 3D-CRT, the median difference for the PTV D95 was -0.1% (range: -4.7% to 9.6%; p = 0.62) and the lung V20 was -4.2% (range: -9.4 to 5.4; p < 0.01). For IMRT, the median difference for the PTV D95 was -10.0% (range: -15.1% to -5.3%; p < 0.01) and the lung V20 was -8.9% (range: -17.3 to -3.5; p < 0.01). Traditional planning without tissue heterogeneity corrections results in an overall decrease in the dose delivered to the target compared with those that incorporate tissue heterogeneity corrections. These differences are modest for 3D treatment plans but may result in clinically relevant differences for the IMRT cohort (>5% deviation).

  • Open Access

    New dosimetric guidelines for linear Boltzmann transport equations through comparative evaluation of stereotactic body radiation therapy for lung treatment planning

    by Matthew Webster, Sean Tanny, Neil Joyce, Amy Herman, Yuhchyau Chen, Michael Milano, Kenneth Usuki, Louis Constine, Deepinder Singh, Inhwan Yeo

    Purpose To propose guidelines for lung stereotactic body radiation therapy (SBRT) when using Acuros XB (AXB) equivalent to the existing ones developed for convolution algorithms such as analytic anisotropic algorithm (AAA), considering the difference between the algorithms. Methods A retrospective analysis was performed on 30 lung patients previously treated with SBRT. The original AAA plans, which were developed using dynamic conformal arcs, were recalculated and then renormalized for planning target volume (PTV) coverage using AXB. The recalculated and renormalized plans were compared to the original plans based on V100% and V90% PTV coverage, as well as V105%, conformality index, D2cm, Rx/Dmax, R50, and Dmin. These metrics were analyzed nominally and on variations according to RTOG and NRG guidelines. Based on the relative difference between each metric in the AAA and AXB plans, new guidelines were developed. The relative differences in our cohort were compared to previously documented AAA to AXB comparisons found in the literature. Results AAA plans recalculated in AXB had a significant reduction in most dosimetric metrics. The most notable changes were in V100% (4%) and the conformality index (7.5%). To achieve equal PTV coverage, AXB required an average of 1.8% more monitor units (MU). This fits well with previously published data. Applying the new guidelines to the AXB plans significantly increased the number of minor violations with no change in major violations, making them comparable to those of the original AAA plans. Conclusion The relative difference found between AAA and AXB for SBRT lung plans has been shown to be consistent with previous works. Based on these findings, new guidelines for lung SBRT are recommended when planning with AXB.