Prevention of harmful EDM currents in inverter-fed AC machines by use of electrostatic shields in the stator winding overhang
Authors:
- 1 November 2010
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 1553572X,p. 962-967
Abstract
In this paper, an inexpensive mitigation technique is used for prevention of harmful EDM currents in small power inverter-fed AC machines. An electrostatic shield is mounted close to the stator winding overhang to eliminate the capacitive coupling between the stator end winding and the rotor surface. The bearing voltage that is caused by the common mode voltage at the motor terminals via the machine capacitances is reduced and the harmful EDM currents are eliminated. A 3D finite element method (FEM) is proposed for the calculation of the machine capacitances. The results are verified by analytical calculation, 2D FEM calculation and measurements.Keywords
This publication has 9 references indexed in Scilit:
- Scaling Effects of Inverter-Induced Bearing Currents in AC MachinesIEEE Transactions on Industry Applications, 2008
- Application of Static Charge Dissipation to Mitigate Electric Discharge Bearing CurrentsIEEE Transactions on Industry Applications, 2008
- Prediction of common mode ground current in motors of inverter-based drive systems2007
- Calculation of Motor Capacitances for Prediction of the Voltage Across the Bearings in Machines of Inverter-Based Drive SystemsIEEE Transactions on Industry Applications, 2007
- Practical Rules for Assessment of Inverter-Induced Bearing Currents in Inverter-Fed AC Motors up to 500 kWIEEE Industrial Electronics Magazine, 2007
- Generation of high-frequency common mode currents in machines of inverter-based drive systems2005
- Use of extra degrees of freedom in multilevel drivesIEEE Transactions on Industrial Electronics, 2002
- Bearing currents and their relationship to PWM drivesIEEE Transactions on Power Electronics, 1997
- An evaluation of the electrostatic shielded induction motor: a solution for rotor shaft voltage buildup and bearing currentIEEE Transactions on Industry Applications, 1997