Impact of Intramedullary Implants on Metallic Element Homeostasis in Children with Forearm Fractures
Open Access
- 4 November 2025
- journal article
- research article
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (21) , 7829
Abstract
Background/Objectives: Childhood is marked by frequent musculoskeletal injuries, with fractures representing a major cause of pediatric trauma admissions. Unstable long-bone fractures often require surgical stabilization, commonly achieved using elastic stable intramedullary nailing (ESIN). Although this method ensures effective fixation and early mobilization, concerns remain regarding potential metal ion release in growing children. This study aimed to assess changes in calcium, magnesium, copper, zinc, titanium, and aluminum concentrations in blood and material from the medullary cavity of forearm fractures following intramedullary fixation. Methods: A prospective study was conducted on 40 patients aged 4–15 years treated with ESIN at the University Children’s Hospital in Lublin. Peripheral blood and material from the medullary cavity were collected before implantation and at implant removal. Elemental concentrations were determined using high-resolution ICP-OES, and statistical analyses included paired comparisons, delta values, and multivariate methods. Results: No significant systemic changes were found for calcium, magnesium, copper, zinc, or aluminum. A modest but significant increase in blood titanium levels was observed after treatment (p = 0.0075), especially in patients with two rods. Multivariate analysis confirmed overall stability of elemental profiles, with titanium contributing most strongly to post-treatment variation. Conclusions: Intramedullary titanium fixation in children does not significantly disrupt systemic mineral homeostasis. The slight increase in circulating titanium reflects implant exposure rather than toxicity, supporting the safety of ESIN, although continued monitoring of metallic elements may be warranted.Keywords
Funding Information
- Uniwersytet Medyczny w Lublinie (DS 51, DS 426)
This publication has 38 references indexed in Scilit:
- Blood and plasma titanium levels associated with well-functioning hip implantsJournal of Trace Elements in Medicine and Biology, 2020
- Titanium Alloy Intramedullary Nails and Plates Affect Serum Metal Ion Levels within the Fracture Healing PeriodBiological Trace Element Research, 2019
- In vivo blood metal ion levels in patients after total shoulder arthroplastyJournal of Shoulder and Elbow Surgery, 2019
- Local and systemic metal ion release occurs intraoperatively during correction and instrumented spinal fusion for scoliosisJournal of Children's Orthopaedics, 2015
- Systematic review: Functional outcomes and complications of intramedullary nailing versus plate fixation for both-bone diaphyseal forearm fractures in childrenInjury, 2014
- Hip implants – Paper VI – Ion concentrationsMaterials & Design (1980-2015), 2007
- The use of elastic intramedullary nailing in the stabilisation of paediatric fracturesInjury, 2005
- State-of-the-art treatment of forearm shaft fracturesInjury, 2005
- Metal ion release from metal implantsMaterials Science and Engineering: C, 2004
- Sister chromatid exchanges and ion release in patients wearing fracture fixation devicesJournal of Biomedical Materials Research, 2000