Computational Comparison of the Mechanical Behavior of Aortic Stent-Grafts Derived from Auxetic Unit Cells
Open Access
- 18 December 2023
- journal article
- research article
- Published by Springer Nature in Cardiovascular Engineering and Technology
- Vol. 15 (2) , 199-210
Abstract
Purpose: Inappropriate stent-graft (SG) flexibility has been frequently associated with endovascular aortic repair (EVAR) complications such as endoleaks, kinks, and SG migration, especially in tortuous arteries. Stents derived from auxetic unit cells have shown some potential to address these issues as they offer an optimum trade-off between radial stiffness and bending flexibility. Methods: In this study, we utilized an established finite element (FE)-based approach to replicate the mechanical response of a SG iliac limb derived from auxetic unit cells in a virtual tortuous iliac aneurysm using a combination of a 180° U-bend and intraluminal pressurization. This study aimed to compare the mechanical performance (flexibility and durability) of SG limbs derived from auxetic unit cells and two commercial SG limbs (Z-stented SG and circular-stented SG models) in a virtual tortuous iliac aneurysm. Maximal graft strain and maximum stress in stents were employed as criteria to estimate the durability of SGs, whereas the maximal luminal reduction rate and the bending stiffness were used to assess the flexibility of the SGs. Results: SG limbs derived from auxetic unit cells demonstrated low luminal reduction (range 4–12%) with no kink, in contrast to Z-stented SG, which had a kink in its central area alongside a high luminal reduction (44%). Conclusions: SG limbs derived from auxetic unit cells show great promise for EVAR applications even at high angulations such as 180°, with acceptable levels of durability and flexibility.Keywords
Funding Information
- H2020 Marie Skłodowska-Curie Actions (859836)
This publication has 31 references indexed in Scilit:
- Endovascular Repair of Abdominal Aortic Aneurysms: Vascular Anatomy, Device Selection, Procedure, and Procedure-specific ComplicationsRadioGraphics, 2015
- Deployment of stent grafts in curved aneurysmal arteries: toward a predictive numerical toolInternational Journal for Numerical Methods in Biomedical Engineering, 2014
- Filling the void: A coalescent numerical and experimental technique to determine aortic stent graft mechanicsJournal of Biomechanics, 2013
- Finite Element Analysis of the Mechanical Performances of 8 Marketed Aortic Stent-GraftsJournal of Endovascular Therapy, 2013
- Severe Bending of Two Aortic Stent-Grafts: An Experimental and Numerical Mechanical AnalysisAnnals of Biomedical Engineering, 2012
- Computational comparison of the bending behavior of aortic stent-graftsJournal of the Mechanical Behavior of Biomedical Materials, 2012
- Computational mechanics of Nitinol stent graftsJournal of Biomechanics, 2008
- Explant analysis of AneuRx stent grafts: relationship between structural findings and clinical outcomeJournal of Vascular Surgery, 2004
- A survey of stent designsMinimally Invasive Therapy & Allied Technologies, 2002
- Time-Related Alterations in Shape, Position, and Structure of Self-Expanding, Modular Aortic Stent-Grafts: A 4-year Single-Center Follow-upJournal of Endovascular Therapy, 1999