Woo-Suck Han
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Woo-Suck Han has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Jerome Molimard
Mines Saint-Etienne, Univ Lyon, Univ Jean Monnet, INSERM, U 1059 Sainbiose, Centre CIS, Saint-Etienne, France
5 shared publications - Reynald Convert
Thuasne, BP243, 92307, Levallois-Perret Cedex, France
3 shared publications Boris Dousteyssier
Ecole Nationale Supérieure des Mines de Saint-Etienne
2 shared publicationsChafiaa Hamitouche
2 shared publicationsEric Stindel
2 shared publicationsJérôme Molimard
Mines Saint-Etienne, Université Jean Monnet, INSERM, UMR1059, SAINBIOSE, CIS-EMSE
2 shared publications
Latest Publications
- Open Access
- 18 December 2023
- Published by Springer Nature in Cardiovascular Engineering and Technology
- Vol. 15 (2) , 199-210
Computational Comparison of the Mechanical Behavior of Aortic Stent-Grafts Derived from Auxetic Unit Cells
Purpose: Inappropriate stent-graft (SG) flexibility has been frequently associated with endovascular aortic repair (EVAR) complications such as endoleaks, kinks, and SG migration, especially in tortuous arteries. Stents derived from auxetic unit cells have shown some potential to address these issues as they offer an optimum trade-off between radial stiffness and bending flexibility. Methods: In this study, we utilized an established finite element (FE)-based approach to replicate the mechanical response of a SG iliac limb derived from auxetic unit cells in a virtual tortuous iliac aneurysm using a combination of a 180° U-bend and intraluminal pressurization. This study aimed to compare the mechanical performance (flexibility and durability) of SG limbs derived from auxetic unit cells and two commercial SG limbs (Z-stented SG and circular-stented SG models) in a virtual tortuous iliac aneurysm. Maximal graft strain and maximum stress in stents were employed as criteria to estimate the durability of SGs, whereas the maximal luminal reduction rate and the bending stiffness were used to assess the flexibility of the SGs. Results: SG limbs derived from auxetic unit cells demonstrated low luminal reduction (range 4–12%) with no kink, in contrast to Z-stented SG, which had a kink in its central area alongside a high luminal reduction (44%). Conclusions: SG limbs derived from auxetic unit cells show great promise for EVAR applications even at high angulations such as 180°, with acceptable levels of durability and flexibility.
- 18 December 2023
- Published by Springer Nature in Cardiovascular Engineering and Technology
- Vol. 15 (2) , 199-210
Open AccessComputational Comparison of the Mechanical Behavior of Aortic Stent-Grafts Derived from Auxetic Unit Cells
Purpose: Inappropriate stent-graft (SG) flexibility has been frequently associated with endovascular aortic repair (EVAR) complications such as endoleaks, kinks, and SG migration, especially in tortuous arteries. Stents derived from auxetic unit cells have shown some potential to address these issues as they offer an optimum trade-off between radial stiffness and bending flexibility. Methods: In this study, we utilized an established finite element (FE)-based approach to replicate the mechanical response of a SG iliac limb derived from auxetic unit cells in a virtual tortuous iliac aneurysm using a combination of a 180° U-bend and intraluminal pressurization. This study aimed to compare the mechanical performance (flexibility and durability) of SG limbs derived from auxetic unit cells and two commercial SG limbs (Z-stented SG and circular-stented SG models) in a virtual tortuous iliac aneurysm. Maximal graft strain and maximum stress in stents were employed as criteria to estimate the durability of SGs, whereas the maximal luminal reduction rate and the bending stiffness were used to assess the flexibility of the SGs. Results: SG limbs derived from auxetic unit cells demonstrated low luminal reduction (range 4–12%) with no kink, in contrast to Z-stented SG, which had a kink in its central area alongside a high luminal reduction (44%). Conclusions: SG limbs derived from auxetic unit cells show great promise for EVAR applications even at high angulations such as 180°, with acceptable levels of durability and flexibility.
- 25 June 2023
- Published by Elsevier
- p. 293-308
Reduced mechanical models of trunk–lumbar belt interaction for design-oriented in-silico clinical trials
- 25 June 2023
- Published by Elsevier
- p. 293-308
Reduced mechanical models of trunk–lumbar belt interaction for design-oriented in-silico clinical trials
- Open Access
- 26 December 2022
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 138, 105644
Potential of auxetic designs in endovascular aortic repair: A computational study of their mechanical performance
- 26 December 2022
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 138, 105644
Open AccessPotential of auxetic designs in endovascular aortic repair: A computational study of their mechanical performance
- Open Access
- 8 October 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (19) , 10100
An In-Silico Study on the Therapeutic Effect of Low Back Belts: Biomechanical Correlation between Belt Design and Patient Morphology
A comparative study of eight different lumbar belts, which are representative of the French market, was carried out on four typical morphologies of patients to assess their therapeutic effects and identify the correlation between the therapeutic parameters and mechanical ones. Four typical morphologies were chosen among 15 patients that had been chosen for the clinical study: tall-large, small-large, tall-thin, and small-thin. Simplified 3D finite elements (FE) models of the trunk according to each patient’s morphology were used for numerical analyses using Abaqus SimuliaTM. The same material properties of the body structures and boundary conditions were taken for all models to only focus on morphological variations. The material properties of eight lumbar belts were obtained by mechanical testing. The pressure applied by the belt to the trunk was modelled by Laplace’s law. The influences of belt types on typical morphologies were analyzed and synthetized to show which parameters are significant for biomechanical efficacy and attendance to the therapeutic effects. Finally, we found the following belt effects: (i) the lumbar belt is more efficient on the thin morphology than the large one, (ii) all mechanical values checked on the vertebral disks and vertebrae have a strong correlation with the correction of lordosis angle, and (iii) the belt’s global stiffness is an important parameter for generating the pressure applied to the trunk.
- 8 October 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (19) , 10100
Open AccessAn In-Silico Study on the Therapeutic Effect of Low Back Belts: Biomechanical Correlation between Belt Design and Patient Morphology
A comparative study of eight different lumbar belts, which are representative of the French market, was carried out on four typical morphologies of patients to assess their therapeutic effects and identify the correlation between the therapeutic parameters and mechanical ones. Four typical morphologies were chosen among 15 patients that had been chosen for the clinical study: tall-large, small-large, tall-thin, and small-thin. Simplified 3D finite elements (FE) models of the trunk according to each patient’s morphology were used for numerical analyses using Abaqus SimuliaTM. The same material properties of the body structures and boundary conditions were taken for all models to only focus on morphological variations. The material properties of eight lumbar belts were obtained by mechanical testing. The pressure applied by the belt to the trunk was modelled by Laplace’s law. The influences of belt types on typical morphologies were analyzed and synthetized to show which parameters are significant for biomechanical efficacy and attendance to the therapeutic effects. Finally, we found the following belt effects: (i) the lumbar belt is more efficient on the thin morphology than the large one, (ii) all mechanical values checked on the vertebral disks and vertebrae have a strong correlation with the correction of lordosis angle, and (iii) the belt’s global stiffness is an important parameter for generating the pressure applied to the trunk.
- Open Access
- 14 April 2022
- Published by MDPI AG in Biomechanics
- Vol. 2 (2) , 174-188
Feasibility of a Full-Field Measurements-Based Protocol for the Biomechanical Study of a Lumbar Belt: A Case Study
Low back pain represents a major economic and societal challenge due to its high prevalence. Lumbar orthoses are one of the recommended treatments. Even if previous results showed their clinical effects, the detailed mode of action is still poorly known, making the device design difficult. A renewed instrumentation and experimental protocol should bring better insight into the lumbar brace–trunk mechanical interaction. This instrumentation should give detailed information on the basic physical or geometrical parameters: the pressure applied on the trunk, the body shape and the strain in the belt. The principal objective of this study was to propose and validate a new measurement protocol, based on pressure mapping systems and full-field shape and strain measurement. The feasibility of the protocol was tested along with its validity and repeatability. The influence of various parameters, which could cause changes in the measurements, was tested with six different belt configurations on one subject. Measurements were also performed to study the impact of posture on pressure and strain. Both pressure and strain appeared to be asymmetric from left to right. The pressure applied by the lumbar belt on the back varies with breathing and with posture. This study showed that full-field measurements were necessary to render the high variability of pressure or strain around the trunk, under recommendations of their use to guarantee a satisfying repeatability.
- 14 April 2022
- Published by MDPI AG in Biomechanics
- Vol. 2 (2) , 174-188
Open AccessFeasibility of a Full-Field Measurements-Based Protocol for the Biomechanical Study of a Lumbar Belt: A Case Study
Low back pain represents a major economic and societal challenge due to its high prevalence. Lumbar orthoses are one of the recommended treatments. Even if previous results showed their clinical effects, the detailed mode of action is still poorly known, making the device design difficult. A renewed instrumentation and experimental protocol should bring better insight into the lumbar brace–trunk mechanical interaction. This instrumentation should give detailed information on the basic physical or geometrical parameters: the pressure applied on the trunk, the body shape and the strain in the belt. The principal objective of this study was to propose and validate a new measurement protocol, based on pressure mapping systems and full-field shape and strain measurement. The feasibility of the protocol was tested along with its validity and repeatability. The influence of various parameters, which could cause changes in the measurements, was tested with six different belt configurations on one subject. Measurements were also performed to study the impact of posture on pressure and strain. Both pressure and strain appeared to be asymmetric from left to right. The pressure applied by the lumbar belt on the back varies with breathing and with posture. This study showed that full-field measurements were necessary to render the high variability of pressure or strain around the trunk, under recommendations of their use to guarantee a satisfying repeatability.
- 14 August 2019
- Published by Springer Nature
- p. 43-59
Parametric Study of Lumbar Belts in the Case of Low Back Pain: Effect of Patients’ Specific Characteristics
- 14 August 2019
- Published by Springer Nature
- p. 43-59
Parametric Study of Lumbar Belts in the Case of Low Back Pain: Effect of Patients’ Specific Characteristics
- 31 August 2017
- Published by Springer Nature in Lecture Notes in Bioengineering
- p. 115-128
Soft Tissues’ Loadings on Healthy Knee at Different Physiological Flexions: A Coupled Experimental–Numerical Approach
- 31 August 2017
- Published by Springer Nature in Lecture Notes in Bioengineering
- p. 115-128
Soft Tissues’ Loadings on Healthy Knee at Different Physiological Flexions: A Coupled Experimental–Numerical Approach
- 1 September 2016
- Published by Elsevier in Annals of Physical and Rehabilitation Medicine
- Vol. 59, e32-e33
Patient dependent knee modeling at several flexion angles: A study on soft tissues loadings
- 1 September 2016
- Published by Elsevier in Annals of Physical and Rehabilitation Medicine
- Vol. 59, e32-e33
Patient dependent knee modeling at several flexion angles: A study on soft tissues loadings
- 30 July 2014
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 17 (sup1) , 62-63
Biomechanical analysis and modelling of lumbar belt: parametric study
- 30 July 2014
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 17 (sup1) , 62-63
Biomechanical analysis and modelling of lumbar belt: parametric study
- 21 January 2013
- Published by SAGE Publications in Journal of Reinforced Plastics and Composites
- Vol. 32 (5) , 308-317
Numerical simulation of RTM process using the extended finite element method combined with the level set method
Numerical simulation for resin transfer moulding manufacturing process is attempted using the extended finite element method combined with the level set method. The level set method is used to transport the resin flow front at each time step during the mould filling. Extended finite element method allows to obtaining a good numerical precision of the resin pressure near the resin flow front, where the gradient of the pressure could be discontinuous. The enriched shape functions of extended finite element method are derived using the level set values so as to correctly describe these shape functions with the resin flow front. In addition, the position of the resin flow front at each time step is calculated by an implicit characteristic Galerkin finite element method. Some examples are presented to validate our study in comparison with analytical or experimental results and to illustrate its industrial applications.
- 21 January 2013
- Published by SAGE Publications in Journal of Reinforced Plastics and Composites
- Vol. 32 (5) , 308-317
Numerical simulation of RTM process using the extended finite element method combined with the level set method
Numerical simulation for resin transfer moulding manufacturing process is attempted using the extended finite element method combined with the level set method. The level set method is used to transport the resin flow front at each time step during the mould filling. Extended finite element method allows to obtaining a good numerical precision of the resin pressure near the resin flow front, where the gradient of the pressure could be discontinuous. The enriched shape functions of extended finite element method are derived using the level set values so as to correctly describe these shape functions with the resin flow front. In addition, the position of the resin flow front at each time step is calculated by an implicit characteristic Galerkin finite element method. Some examples are presented to validate our study in comparison with analytical or experimental results and to illustrate its industrial applications.