Scratch and Wear Behaviour of Co-Cr-Mo Alloy in Ringer’s Lactate Solution
Authors:
- Raimundo SilvaRaimundo Silva
- Marcos Dantas dos SantosMSMarcos Dantas dos Santos
- Rui MadureiraRui Madureira
- Rui SoaresRSRui Soares
- Rui NetoRNRui Neto
- Ângela Aparecida VieiraÂVÂngela Aparecida Vieira
- Polyana Alves Radi GonçalvesPolyana Alves Radi Gonçalves
- Priscila Maria Sarmeiro M. LeitePLPriscila Maria Sarmeiro M. Leite
- Lúcia VieiraLVLúcia Vieira
- Filomena VianaFilomena Viana
Open Access
Abstract
Cobalt–chromium–molybdenum (Co-Cr-Mo) alloy is a material recommended for biomedical implants; however, to be suitable for this application, it should have good tribological properties, which are related to grain size. This paper investigates the tribological behaviour of a Co-Cr-Mo alloy produced using investment casting, together with electromagnetic stirring, to reduce its grain size. The samples were subjected to wear and scratch tests in simulated body fluid (Ringer’s lactate solution). Since a reduction in grain size can influence the behaviour of the material, in terms of resistance and tribological response, four samples with different grain sizes were produced for use in our investigation of the behaviour of the alloy, in which we considered the friction coefficient, wear, and scratch resistance. The experiments were performed using a tribometer, with mean values for the friction coefficient, normal load, and tangential force acquired and recorded by the software. Spheres of Ti-6Al-4V and 316L steel were used as counterface materials. In addition, to elucidate the influence of grain size on the mechanical properties of the alloy, observations were conducted via scanning electron microscopy (SEM) with electron backscatter diffraction (EBSD). The results showed changes in the structure, with a reduction in grain size from 5.51 to 0.79 mm. Using both spheres, the best results for the friction coefficient and wear volume corresponded to the sample with the smallest grain size of 0.79 mm. The friction coefficients obtained were 0.37 and 0.45, using the Ti-6Al-4V and 316L spheres, respectively. These results confirm that the best surface finish for Co-Cr-Mo alloy used as a biomedical implant is one with a smaller grain size, since this results in a lower friction coefficient and low wear.Keywords
Funding Information
- GRIS project (POCI-01-0145-FEDER-032460, POCI-01-0247-FEDER-038128, POCI-01-0247-FEDER-045391)
- COMPETE 2020, through FEDER and FCT (POCI-01-0145-FEDER-032460, POCI-01-0247-FEDER-038128, POCI-01-0247-FEDER-045391)
- projects MAGIC 4.0 (POCI-01-0145-FEDER-032460, POCI-01-0247-FEDER-038128, POCI-01-0247-FEDER-045391)
- HIPERCAST (POCI-01-0145-FEDER-032460, POCI-01-0247-FEDER-038128, POCI-01-0247-FEDER-045391)
This publication has 63 references indexed in Scilit:
- Tantalum-based multilayer coating on cobalt alloys in total hip and knee replacementMaterials Science and Engineering: C, 2012
- Effect of Ringer's Solution on Wear and Friction of Stainless Steel 316L after Plasma Electrolytic Nitrocarburising at Low VoltagesJournal of Materials Science & Technology, 2011
- Nanomechanical and nanotribological properties of carbon-based thin films: A reviewInternational Journal of Refractory Metals and Hard Materials, 2010
- Tribology and total hip joint replacement: Current concepts in mechanical simulationMedical Engineering & Physics, 2008
- Microstructure and corrosion behaviour in biological environments of the new forged low-Ni Co–Cr–Mo alloysBiomaterials, 2005
- Subsurface microstructure of metal‐on‐metal hip joints and its relationship to wear particle generationJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2004
- Measurement of hardness and elastic modulus by instrumented indentation: Advances in understanding and refinements to methodologyJournal of Materials Research, 2004
- The composition of the surface passive film formed on CoCrMo alloy in simulated physiological solutionElectrochimica Acta, 2003
- An improved technique for determining hardness and elastic modulus using load and displacement sensing indentation experimentsJournal of Materials Research, 1992
- Corrosion Resistance of Titanium Surgical Implant Alloys: A Review1979