AVAngela Aparecida Vieira

Angela Aparecida Vieira

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Angela Aparecida Vieira has a total of 24 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Enhancing UV Radiation Resilience of DLC-Coated Stainless Steel with TiO2: A Dual-Layer Approach

    by Paulo Fabrício Macário, Carolina Hahn da Silveira, Angela Aparecida Moraes Vieira, André Ricardo Marcondes, Francisco das Chagas Marques, Guilhermino José Macêdo Fechine, Lúcia Vieira

    This study presents an innovative dual-layer coating approach integrating titanium dioxide (TiO2) onto diamond-like carbon (DLC)-coated 316L stainless steel. The combination of PECVD-deposited DLC and ALD-deposited TiO2 aims to preserve the inherent tribological properties of DLC while mitigating UV-induced degradation. By leveraging the ability of TiO2 to absorb, reflect, and scatter UV light, this dual-layer strategy significantly enhances the durability of DLC coatings in radiation-prone environments. The effects of accelerated aging through UV exposure on DLC and DLC/TiO2 films were evaluated using an Accelerated Weathering Tester. Comprehensive analyses were conducted to assess the structural and mechanical properties before and after UV exposure, including Raman spectroscopy, profilometry, SEM, EDS, nanoindentation, and tribometry. The results demonstrate that the TiO2 layer effectively mitigates UV-induced damage, preserving the DLC film’s integrity and tribological performance even after 408 h of UV aging. Specifically, the DLC/TiO2 coatings maintained lower roughness, higher hardness, and better adhesion than DLC-only coatings under identical conditions. This research significantly advances protective coating technology by enhancing the durability and performance of DLC films, particularly in aerospace and other demanding industries where exposure to UV radiation is a critical concern.


  • Open Access

    Wear Rate, Tribo-Corrosion, and Plastic Deformation Values of Co-Cr-Mo Alloy in Ringer Lactate Solution

    by Raimundo Nonato Alves Silva, Rui Neto, Angela Vieira, Priscila Leite, Polyana Radi, Carolina Hahn da Silveira, M. D. Santos, Filomena Viana, Lúcia Vieira

    This study investigates the tribocorrosion performance of a cast Co-Cr-Mo alloy prepared using casting and electromagnetic stirring (EMS) at specific frequencies. The tribocorrosion behaviour of the alloy was evaluated when exposed to Ringer’s lactate solution to optimize the EMS parameters and improve its properties. The research focuses on biomedical implant applications and explores how EMS affects alloy wear and corrosion resistance. As did the friction coefficient and wear volume, the wear rate of samples produced with EMS frequencies of 75 Hz and 150 Hz decreased. These improvements are attributed to the ability of EMS to refine grain size and homogenize the microstructure, thereby increasing the resistance to tribocorrosion. Techniques such as scanning electron microscopy (SEM) and profilometry were used for surface and wear analysis, while mechanical properties were evaluated through instrumented indentation tests. The findings confirm that EMS improves the alloy’s durability and tribocorrosion resistance, making it highly suitable for demanding biomedical applications such as joint replacements. This highlights the importance of advanced manufacturing techniques in optimizing biomedical alloys for simulated body conditions.


  • Open Access

    Tribocorrosion Susceptibility and Cell Viability Study of 316L Stainless Steel and Ti6Al4V Titanium Alloy with and without DLC Coatings

    by Ana Claudia Sene, Michely Glenda Pereira da Silva, Paulo Fabrício Macário, Angela Aparecida Vieira, Priscila Maria Sarmeiro Correa Marciano Leite, Newton Soares da Silva, Francisco Das Chagas Marques, Lúcia Vieira

    Stainless steel (SS316L) and titanium alloy (Ti6Al4V) exhibit suitable properties for biomedical applications; however, the tribocorrosion of these materials, which is associated with metallosis, is still a significant concern. This work investigates the effectiveness of DLC smoothing coatings applied to the metals to reduce tribocorrosion and improve cell viability. The study was motivated by many reports of metallosis caused by metal debris in the soft tissues of the body. DLC coatings were produced using the plasma-enhanced chemical vapor deposition (PECVD) technique. The cytotoxicity, genotoxicity, and cell viability of metallic samples with and without DLC coatings were analyzed, considering the chemical composition of the coating and metallic components. The results show that the DLC coatings presented suitable interaction properties and no cytotoxicity or genotoxicity when exposed to the cellular environment, compared with the control group (p < 0.0001). They also demonstrated cell viability, low friction representing a reduction of 80%, and hardness 23–26 GPa, making them ideal for use on fixed implants. It is necessary to control the thickness and roughness of the coating to avoid pinholes and increase the corrosion protection of implants. These DLC coatings with low friction coefficients could facilitate the fixation of implantable pins and screws, including Kirschner wires.


  • Open Access

    Crystalline Structure, Morphology, and Adherence of Thick TiO2 Films Grown on 304 and 316L Stainless Steels by Atomic Layer Deposition

    by Vagner Eduardo Caetano Marques, Lucas Augusto Manfroi, Angela Aparecida Vieira, André Luis de Jesús Pereira, Francisco das Chagas Marques, Lúcia Vieira

    Titanium dioxide (TiO2) thin films are widely used in transparent optoelectronic devices due to their excellent properties, as well as in photocatalysis, cosmetics, and many other biomedical applications. In this work, TiO2 thin films were deposited onto AISI 304 and AISI 316L stainless steel substrates by atomic layer deposition, followed by comparative evaluation of the mixture of anatase and rutile phase by X-ray diffraction, Raman maps, morphology by SEM-FEG-AFM, and adhesion of the films on the two substrates, aiming to evaluate the scratch resistance. Raman spectroscopy mapping and X-ray diffraction with Rietveld refinement showed that the films were composed of anatase and rutile phases, in different percentages. Scratch testing using a diamond tip on the TiO2 film was employed to evaluate the film adherence and to determine the friction coefficient, with the results showing satisfactory adherence of the films on both substrates.


  • Open Access

    Scratch and Wear Behaviour of Co-Cr-Mo Alloy in Ringer’s Lactate Solution

    by Raimundo Silva, Marcos Dantas dos Santos, Rui Madureira, Rui Soares, Rui Neto, Ângela Aparecida Vieira, Polyana Alves Radi Gonçalves, Priscila Maria Sarmeiro M. Leite, Lúcia Vieira, Filomena Viana

    Cobalt–chromium–molybdenum (Co-Cr-Mo) alloy is a material recommended for biomedical implants; however, to be suitable for this application, it should have good tribological properties, which are related to grain size. This paper investigates the tribological behaviour of a Co-Cr-Mo alloy produced using investment casting, together with electromagnetic stirring, to reduce its grain size. The samples were subjected to wear and scratch tests in simulated body fluid (Ringer’s lactate solution). Since a reduction in grain size can influence the behaviour of the material, in terms of resistance and tribological response, four samples with different grain sizes were produced for use in our investigation of the behaviour of the alloy, in which we considered the friction coefficient, wear, and scratch resistance. The experiments were performed using a tribometer, with mean values for the friction coefficient, normal load, and tangential force acquired and recorded by the software. Spheres of Ti-6Al-4V and 316L steel were used as counterface materials. In addition, to elucidate the influence of grain size on the mechanical properties of the alloy, observations were conducted via scanning electron microscopy (SEM) with electron backscatter diffraction (EBSD). The results showed changes in the structure, with a reduction in grain size from 5.51 to 0.79 mm. Using both spheres, the best results for the friction coefficient and wear volume corresponded to the sample with the smallest grain size of 0.79 mm. The friction coefficients obtained were 0.37 and 0.45, using the Ti-6Al-4V and 316L spheres, respectively. These results confirm that the best surface finish for Co-Cr-Mo alloy used as a biomedical implant is one with a smaller grain size, since this results in a lower friction coefficient and low wear.


  • Open Access

    Heterostructure, Morphology, and Adherence Evaluation of TiO2 Film Deposited on Stainless Steel 304 and 316L via Atomic Layer Deposition

    by Vagner Eduardo Marques, Lucas Augusto Manfroi, Angela Aparecida Vieira, Andre Luis de Jesus Pereira, Francisco das Chagas Marques, Lúcia Vieira

    Titanium dioxide (TiO2) thin films have been widely used in transparent optoelectronic devices owing to their excellent optical properties also is used in photocatalysis, cosmetics, and many other biomedical applications. However, a lack of studies was published on microstructure and adherence comparison of the TiO2 deposited on both AISI substrates. In this work, TiO2 thin films were deposited onto AISI 304 and AISI 316L stainless steel (SS) substrates via atomic layer deposition. Its heterostructure, morphology, and adhesion were compared in both substrates looking for synergistic and multifunctional properties. Raman spectroscopy mapping and X-ray diffraction using the Rietveld refinement method showed that the films are composed of anatase and rutile phases in different percentages. Scratching tests were used to analyze the film adher-ence and friction between a diamond tip and TiO2 film, showing well adhered in both substrates.