Internal Adaptation of Implant-Supported, Polymer-Infused Ceramic Crowns Fabricated by Two CAD/CAM Systems
Authors:
- 22 October 2018
- journal article
- research article
- Published by Wiley in Journal of Prosthodontics
- Vol. 27 (9) , 868-876
Abstract
Purpose The aim of this in vitro study was to compare the internal 3D adaptation of polymer‐infused ceramic crowns fabricated using two CAD/CAM systems: CEREC inLab MC XL and Ceramill Motion 2 (5X). Materials and Methods Twenty‐five implant‐supported metal‐ceramic crowns were fabricated conventionally using the lost‐wax technique, and the outer contour was scanned to serve as a guide for designing the polymer‐infused ceramic CAD/CAM crowns. Twenty‐five crowns were fabricated using CEREC, and 25 crowns were fabricated using Ceramill. The cement space was set to 20 μm. The Zeiss Accura Microsystem Coordinate Measuring Machine (CMM), Calypso, and Geomagic software were used to measure the 3D accuracy of fit of all crowns to their respective implant abutments. To test for the statistical significance between groups in terms of 3D total distortion, a one‐way ANOVA was conducted. The Kolmogorov‐Smirnov test was used to investigate the differences in the x, y, and z coordinates. A p‐value of 0.05 or less was considered statistically significant at an alpha level of 0.05. Results Comparing the 3D misfit of metal‐ceramic crowns to those of CAD/CAM crowns fabricated using CEREC revealed no significant difference (88.20 ± 36.59 μm vs. 102.45 ± 36.58 μm, p = 0.161). Similarly, no significant difference in 3D total distortion was identified between metal‐ceramic crowns and crowns fabricated using Ceramill (88.20 ± 36.59 μm vs. 78.40 ± 31.03 μm, p = 0.336); however, the 3D total distortion of polymer‐infused crowns made by Ceramill was significantly reduced compared to that of crowns fabricated by CEREC (78.3 ± 31.0 μm vs. 102.4 ± 36.5 μm, p = 0.019).. Conclusions Polymer‐infused ceramic crowns fabricated using CEREC exhibited the least accurate 3D fit. All misfit values of the tested groups were within clinically acceptable levels.Keywords
This publication has 42 references indexed in Scilit:
- Accuracy of ceramic restorations made with two CAD/CAM systemsThe Journal of Prosthetic Dentistry, 2013
- CAD/CAM systems available for the fabrication of crown and bridge restorationsAustralian Dental Journal, 2011
- Two imaging techniques for 3D quantification of pre-cementation space for CAD/CAM crownsJournal of Dentistry, 2010
- Precision of Fit to Implants: A Comparison of Cresco™ and Procera® Implant Bridge FrameworksClinical Implant Dentistry and Related Research, 2010
- The Precision of Fit of Milled Titanium Implant Frameworks (I‐Bridge®) in the Edentulous JawClinical Implant Dentistry and Related Research, 2010
- Effect of Superstructure Materials and Misfit on Stress Distribution in a Single Implant-Supported ProsthesisJournal of Craniofacial Surgery, 2010
- Effect of Passive Fit Absence in the Prosthesis/Implant/Retaining Screw SystemJournal of Craniofacial Surgery, 2009
- Scanning Electron Microscope Evaluation of Vertical and Horizontal Discrepancy in Cast Copings for Single-Tooth Implant-Supported ProsthesesImplant Dentistry, 2008
- Bacterial leakage into and from prefabricated screw‐retained implant‐borne crowns in vitroJournal of Oral Rehabilitation, 1998
- Photogrammetric measurements of implant positions. Description of a technique to determine the fit between implants and superstructures.Clinical Oral Implants Research, 1994