Effect of Biometric Characteristics on the Change of Biomechanical Properties of the Human Cornea due to Cataract Surgery
Open Access
- 29 May 2014
- journal article
- research article
- Published by Wiley in BioMed Research International
- Vol. 2014, 1-5
Abstract
Purpose.To determine the impact of biometric characteristics on changes of biomechanical properties of the human cornea due to standard cataract surgery using biomechanical analysis.Patients and Methods.This prospective consecutive cross-sectional study comprised 54 eyes with cataract in stages I or II that underwent phacoemulsification and IOL implantation. CH, CRF, IOPg, and IOPcc intraocular pressure were measured by biomechanical analysis preoperatively and at 1 month postoperatively. Changes () were calculated as preoperative value versus postoperative value. Biometrical data were extracted from TMS-5 (CSI and SAI), IOLMaster (AL), and EM-3000 (CCT and ECC) preoperatively.Results.The average values of the changes were mmHg, mmHg, mmHg, and mmHg. The higher the CSI the smaller the decrease in CH (,). The higher the CCT the larger the decrease in CRF (,). The higher the AL the smaller the decrease in IOPg (,). The higher the AL, SAI, and EEC the smaller the decrease in IOPcc (,;,;,).Conclusions.Corneal biomechanical properties were affected by comprehensive factors after cataract surgery, including corneal endothelium properties, biometry, and geometrical characteristics.
Keywords
This publication has 21 references indexed in Scilit:
- Goldmann applanation tonometry compared with corneal-compensated intraocular pressure in the evaluation of primary open-angle GlaucomaBMC Ophthalmology, 2012
- Factors influencing corneal biomechanical changes after microincision cataract surgery and standard coaxial phacoemulsificationJournal of Cataract & Refractive Surgery, 2010
- Corneal biomechanical properties and intraocular pressure changes after phacoemulsification and intraocular lens implantationJournal of Cataract & Refractive Surgery, 2008
- Ultrastructural analysis of collagen fibrils and proteoglycans in keratoconusActa Ophthalmologica, 2008
- Early intraocular pressure and anterior chamber depth changes after phacoemulsification and intraocular lens implantation in nonglaucomatous eyesJournal of Cataract & Refractive Surgery, 2008
- Corneal biomechanical properties in normal, post-laser in situ keratomileusis, and keratoconic eyesJournal of Cataract & Refractive Surgery, 2007
- Corneal Thickness- and Age-Related Biomechanical Properties of the Cornea Measured with the Ocular Response AnalyzerInvestigative Ophthalmology & Visual Science, 2006
- Ocular Response Analyzer versus Goldmann Applanation Tonometry for Intraocular Pressure MeasurementsInvestigative Ophthalmology & Visual Science, 2006
- Changes in Collagen Orientation and Distribution in Keratoconus CorneasInvestigative Ophthalmology & Visual Science, 2005
- Determining in vivo biomechanical properties of the cornea with an ocular response analyzerJournal of Cataract & Refractive Surgery, 2005