Hybrid blade and locking plate fixation for proximal humerus fractures: a comparative biomechanical analysis
Open Access
- 25 January 2018
- journal article
- research article
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 17 (1) , 10
Abstract
Open reduction and internal fixation of proximal humerus fractures can be difficult to achieve adequate, complication free results due to osteopenia of the proximal humerus and unstable fracture patterns. This study aimed to compare the biomechanical properties of a novel hybrid fixed angle blade plate (Fx plate) with an established fixed angle locking plate (PHILOS plate). A two-part fracture was simulated in synthetic composite humeri by creating a transverse osteotomy and 10 mm fracture gap at the surgical neck. After treating the fractures with either an Fx plate or a PHILOS plate, humeral head was fixed and the shaft was displaced in a cantilever fashion. For elastic tests, loading was along the frontal and sagittal plane to achieve varus/valgus and extension/flexion, respectively. In plastic tests, loading was in a varus direction to determine the constructs’ resistance to varus collapse. In elastic tests, both construct types had higher peak load and stiffness in extension/flexion than varus/valgus. Fx plate constructs were significantly stiffer than PHILOS constructs in varus/valgus (mean: 7.590/6.900 vs. 6.609/6.091 N/mm; p < 0.001 for both) but significantly less stiff in extension/flexion (8.770/9.541 vs. 9.533/9.997 N/mm; p < 0.001 for extension, p < 0.05 for flexion). In varus plastic tests, significantly higher peak loads were reported for Fx plate than PHILOS (134.391 vs. 115.531 N; p < 0.001). In this fracture gap model, humeri implanted with a novel Fx plate provided higher varus/valgus stiffness but lower extension/flexion stiffness than a more traditional proximal humeral locking plate design (PHILOS).Keywords
Funding Information
- DePuy Synthes
This publication has 42 references indexed in Scilit:
- Proximal humeral fracture fixation: a biomechanical comparison of two constructsJournal of Shoulder and Elbow Surgery, 2013
- The clinical benefit of medial support screws in locking plating of proximal humerus fractures: a prospective randomized studyInternational Orthopaedics, 2011
- Pitfalls and complications with locking plate for proximal humerus fractureJournal of Shoulder and Elbow Surgery, 2010
- Biomechanical Evaluation of 3-Part Proximal Humerus Fractures: A Cadaveric StudyOrthopedics, 2009
- Analysis of early failure of the locking compression plate in osteoporotic proximal humerus fracturesJournal of Orthopaedic Science, 2009
- Additive fiber-cerclages in proximal humeral fractures stabilized by locking platesActa Orthopaedica, 2009
- Locking plates improve torsional resistance in the stabilization of three-part proximal humeral fracturesJournal of Shoulder and Elbow Surgery, 2006
- Muskeleffizienz bei totaler Schulterendoprothetik: Abhängigkeit von Kalottenposition und Rotatorenmanschettenfunktion - Muscle Efficiency during Total Shoulder Arthroplasty: Dependence on Position of the Humeral Head and Function of the Rotator CuffBiomedical Engineering / Biomedizinische Technik, 2001
- Semitubular Blade Plate for Fixation in the Proximal HumerusJournal of Orthopaedic Trauma, 1988
- Closed treatment of fractures of the proximal humerusActa Orthopaedica, 1984