Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ali Jabran has a total of 18 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Enhanced BCI Classification Through Dual-Paradigm Integration: A 240-Element Individually Addressable LED Array for SSVEP-P300 Fusion

    by Surej Mouli, Mariyah Asan, Ekgari Kasawala, Aiswarya Raveendran Nair, Ali Jabran

    Brain–computer interfaces (BCIs) offer transformative potential for individuals with severe motor impairments, yet single-paradigm systems remain constrained by classification inaccuracies and susceptibility to signal degradation. This pilot study presents a four-class hybrid SSVEP + P300 BCI system for discrete smart-environment device control, employing a custom-designed 240-element individually addressable NeoPixel LED matrix platform as a novel stimulation architecture. The platform supports simultaneous multi-frequency SSVEP stimulation and event-related P300 cueing within a unified hardware array, whilst its 24-bit colour rendering capability, supporting up to 16 million distinct colours and synchronised multi-unit animations, affords substantial extensibility beyond conventional single-paradigm stimulus systems. Hardware-level frequency verification confirmed accurate stimulus generation across all target frequencies, with a maximum deviation of 0.044% from nominal programmed values. Five healthy participants performed ON/OFF control tasks directed towards a fan and lamp across 3 s and 5 s EEG analysis windows, yielding 400 trials in total. Preliminary descriptive analysis suggests that the hybrid SSVEP + P300 paradigm maintained consistent group mean classification accuracy of 79.0% across both window durations, whilst the SSVEP-only condition exhibited a 7.0 percentage point decline from 79.0% to 72.0% at the extended window. As the two conditions were recorded in separate sessions and the P300 stage functions as a veto gate that cannot increase accuracy, this difference is interpreted cautiously. At the 5 s analysis window, the hybrid paradigm additionally demonstrated a conservative error profile characterised by predominant false negative over false positive activations, with a lower false positive rate than the SSVEP-only condition (8.0% vs. 12.0%). These exploratory findings from a proof-of-concept pilot investigation suggest potential suitability of the proposed approach for reliable and safety-conscious assistive device control, pending validation through larger-scale confirmatory studies with formal statistical analysis.

  • Open Access

    Systematic Evaluation of IMU Sensors for Application in Smart Glove System for Remote Monitoring of Hand Differences

    by Amy Harrison, Andrea Jester, Surej Mouli, Antonio Fratini, Ali Jabran

    Human hands have over 20 degrees of freedom, enabled by a complex system of bones, muscles, and joints. Hand differences can significantly impair dexterity and independence in daily activities. Accurate assessment of hand function, particularly digit movement, is vital for effective intervention and rehabilitation. However, current clinical methods rely on subjective observations and limited tests. Smart gloves with inertial measurement unit (IMU) sensors have emerged as tools for capturing digit movements, yet their sensor accuracy remains underexplored. This study developed and validated an IMU-based smart glove system for measuring finger joint movements in individuals with hand differences. The glove measured 3D digit rotations and was evaluated against an industrial robotic arm. Tests included rotations around three axes at 1°, 10°, and 90°, simulating extension/flexion, supination/pronation, and abduction/adduction. The IMU sensors demonstrated high accuracy and reliability, with minimal systematic bias and strong positive correlations (p > 0.95 across all tests). Agreement matrices revealed high agreement (10°) in only 4 trials. The Root Mean Square Error (RMSE) ranged from 1.357 to 5.262 for the 90° tests, 0.094 to 0.538 for the 10° tests, and 0.129 to 0.36 for the 1° tests. Likewise, mean absolute error (MAE) ranged from 0.967 to 4.679 for the 90° tests, 0.073 to 0.386 for the 10° tests, and 0.102 to 0.309 for the 1° tests. The sensor provided precise measurements of digit angles across 0–90° in multiple directions, enabling reliable clinical assessment, remote monitoring, and improved diagnosis, treatment, and rehabilitation for individuals with hand differences.


  • Open Access

    Non-invasive Quantitative Assessment of Muscle Force Based on Ultrasonic Shear Wave Elastography

    by Jing Liu, Zhihui Qian, Kunyang Wang, Jianan Wu, Ali Jabran, Luquan Ren, Lei Ren


  • Biomechanical comparison of screw-based zones of a spatial subchondral support plate for proximal humerus fractures

    by Ali Jabran, Chris Peach, Zhenmin Zou, Lei Ren

    Stabilisation of proximal humerus fractures remains a surgical challenge. Spatial subchondral support (S3) plate promises to overcome common complications associated with conventional proximal humerus plates. This study compared the biomechanical performance of S3 plate with a fixed-angle hybrid blade (Equinoxe Fx) plate and a conventional fixed-angle locking plate (PHILOS). The effects of removal of different S3 plate screws on the humeral stability were also investigated. A total of 20 synthetic left humeri were osteotomised transversely at the surgical neck to simulate a two-part fracture and were each treated with an S3 plate. Head screws were divided into three zones based on their distance from the fracture site. Specimens were divided into four equal groups where one group acted as a control with all screws and three groups had one of the screw zones missing. With humeral head fixed, humeral shaft was first displaced 5 mm in extension, flexion, valgus and varus direction (elastic testing) and then until 30 mm varus displacement (plastic testing). Load–displacement data were recorded to determine construct stiffness in elastic tests and assess specimens’ varus stability under plastic testing. Removal of the screw nearest to the fracture site led to a 20.71% drop in mean elastic varus bending stiffness. Removal of the two inferomedial screw above it resulted in a larger drop. The proximal screw pair had the largest contribution to extension and flexion bending stiffness. Varus stiffness of S3 plate constructs was higher than PHILOS and Fx plate constructs. Stability of humeri treated with S3 plate depends on screws’ number, orientation and location. Varus stiffness of S3 plate construct (10.54 N/mm) was higher than that of PHILOS (6.61 N/mm) and Fx (7.59 N/mm) plate constructs. We attribute this to S3 plates’ thicker cross section, the 135° inclination of its screws with respect to the humeral shaft and the availability of pegs for subchondral support.


  • Effect of screw thread length on stiffness of proximal humerus locking plate constructs: A finite element study

    by Louise Le, Ali Jabran, Chris Peach, Lei Ren

    Plate-based treatment of proximal humerus fractures is associated with a high risk of complications such as screw perforation into glenohumeral joint. Smooth and threaded pegs were developed with the hope of minimising these risks. No consensus exists onto which threading profile achieves stiffest bone-plate construct. This study investigated the biomechanical effect of five percentages of threading on individual humeral head screws on a bone-plate construct. A finite element model simulating a two-part proximal humerus fracture treated with a Spatial Subchondral Support plate was developed and validated against in vitro biomechanical tests. The proportion of the humeral head screw length that was threaded was varied between 0%-100% in 25% increments. A 5-mm cantilever varus displacement was applied and the required load (F5) was calculated. Full (100%) threading achieved the stiffest construct for all six screws. Fully threading all smooth pegs at once increased F5 by 18%. Threading did not increase F5 equally in all screws. Inferior three plate screws exhibited a larger increase in stiffness than superior three. Most of the mechanical benefits of threading in inferior three screws can be achieved by using threaded pegs (50% threading) while the superior three screws need to be fully threaded. In practice, the smooth surface profile may also offer additional mechanical benefits if implanted with longer lengths and larger diameters. Threading is an effective way of increasing the varus bending stiffness of proximal humerus plates constructs.


  • Open Access

    Parametric Design Optimisation of Proximal Humerus Plates Based on Finite Element Method

    by Ali Jabran, Chris Peach, Zhenmin Zou, Lei Ren

    Optimal treatment of proximal humerus fractures remains controversial. Locking plates offer theoretical advantages but are associated with complications in the clinic. This study aimed to perform parametric design optimisation of proximal humerus plates to enhance their mechanical performance. A finite element (FE) model was developed that simulated a two-part proximal humerus fracture that had been treated with a Spatial Subchondral Support (S3) plate and subjected to varus bending. The FE model was validated against in vitro biomechanical test results. The predicted load required to apply 5 mm cantilever varus bending was only 0.728% lower. The FE model was then used to conduct a parametric optimisation study to determine the orientations of inferomedial plate screws that would yield minimum fracture gap change (i.e. optimal stability). The feasible design space was automatically identified by imposing clinically relevant constraints, and the creation process of each FE model for the design optimisation was automated. Consequently, 538 FE models were generated, from which the obtained optimal model had 4.686% lower fracture gap change (0.156 mm) than that of the manufacturer’s standard plate. Whereas its screws were oriented towards the inferomedial region and within the range of neck-shaft angle of a healthy subject. The methodology presented in this study promises future applications in patient-specific design optimisation of implants for other regions of the human body.


  • Open Access

    Biomechanical comparison of screw-based zoning of PHILOS and Fx proximal humerus plates

    by Ali Jabran, Chris Peach, Zhenmin Zou, Lei Ren

    Treatment of proximal humerus fractures with locking plates is associated with complications. We aimed to compare the biomechanical effects of removing screws and blade of a fixed angle locking plate and hybrid blade plate, on a two-part fracture model. Forty-five synthetic humeri were divided into nine groups where four were implanted with a hybrid blade plate and the remaining with locking plate, to treat a two-part surgical neck fracture. Plates’ head screws and blades were divided into zones based on their distance from fracture site. Two groups acted as a control for each plate and the remaining seven had either a vacant zone or blade swapped with screws. For elastic cantilever bending, humeral head was fixed and the shaft was displaced 5 mm in extension, flexion, valgus and varus direction. Specimens were further loaded in varus direction to investigate their plastic behaviour. In both plates, removal of inferomedial screws or blade led to a significantly larger drop in varus construct stiffness than other zones. In blade plate, insertion of screws in place of blade significantly increased the mean extension, flexion valgus and varus bending stiffness (24.458%/16.623%/19.493%/14.137%). In locking plate, removal of screw zones proximal to the inferomedial screws reduced extension and flexion bending stiffness by 26–33%. Although medial support improved varus stability, two inferomedial screws were more effective than blade. Proximal screws are important for extension and flexion. Mechanical consequences of screw removal should be considered when deciding the number and choice of screws and blade in clinic.


  • Open Access

    A review on topological architecture and design methods of cable-driven mechanism

    by Huajie Hong, Jabran Ali, Lei Ren

    Research on the cable-driven mechanism has greatly developed with the booming of the robots in the past 30 years, and a range of corresponding theoretical studies have been published on them. The large-scale robot or manipulator with the complex cable-driven mechanism can be reconfigured. However, more theoretical studies are required on their topological architecture design and optimization to achieve this. Therefore, the applied cable-driven architectures and the corresponding theoretical studies are reviewed and summarized here. The parallel, serial, and differential architecture are illustrated, as well as their theories and methods, such as the workspace analysis based on the Jacobian matrix, particle swarm optimization and genetic algorithm, and kinematic design based on the graph theory are described. The features of the architecture and the theory studies are concluded. It is hoped that this study will help with design of future studies.


  • Open Access

    Biomechanical analysis of plate systems for proximal humerus fractures: a systematic literature review

    by Ali Jabran, Chris Peach, Lei Ren

    Proximal humerus fractures are the third most common in the human body but their management remains controversial. Open reduction and internal fixation with plates is one of the leading modes of operative treatment for these fractures. The development of technologies and techniques for these plates, during the recent decades, promise a bright future for their clinical use. A comprehensive review of in vitro biomechanical studies is needed for the comparison of plates’ mechanical performance and the testing methodologies. This will not only guide clinicians with plate selection but also with the design of future in vitro biomechanical studies. This review was aimed to systematically categorise and review the in vitro biomechanical studies of these plates based on their protocols and discuss their results. The technologies and techniques investigated in these studies were categorised and compared to reach a census where possible. Web of Science and Scopus database search yielded 62 studies. Out of these, 51 performed axial loading, torsion, bending and/or combined bending and axial loading while 11 simulated complex glenohumeral movements by using tendons. Loading conditions and set-up, failure criteria and performance parameters, as well as results for each study, were reviewed. Only two studies tested four-part fracture model while the rest investigated two- and three-part fractures. In ten studies, synthetic humeri were tested instead of cadaveric ones. In addition to load–displacement data, three-dimensional motion analysis systems, digital image correlation and acoustic emission testing have been used for measurement. Overall, PHILOS was the most tested plate and locking plates demonstrated better mechanical performance than non-locking ones. Conflicting results have been published for their comparison with non-locking blade plates and polyaxial locking screws. Augmentation with cement [calcium phosphate or poly(methyl methacrylate)] or allografts (fibular and femoral head) was found to improve bone-plate constructs’ mechanical performance. Controversy still lies over the use of rigid and semi-rigid implants and the insertion of inferomedial screws for calcar region support. This review will guide the design of in vitro and in silico biomechanical tests and also supplement the study of clinical literature.


  • Open Access

    Hybrid blade and locking plate fixation for proximal humerus fractures: a comparative biomechanical analysis

    by Ali Jabran, Chris Peach, Zhenmin Zou, Lei Ren

    Open reduction and internal fixation of proximal humerus fractures can be difficult to achieve adequate, complication free results due to osteopenia of the proximal humerus and unstable fracture patterns. This study aimed to compare the biomechanical properties of a novel hybrid fixed angle blade plate (Fx plate) with an established fixed angle locking plate (PHILOS plate). A two-part fracture was simulated in synthetic composite humeri by creating a transverse osteotomy and 10 mm fracture gap at the surgical neck. After treating the fractures with either an Fx plate or a PHILOS plate, humeral head was fixed and the shaft was displaced in a cantilever fashion. For elastic tests, loading was along the frontal and sagittal plane to achieve varus/valgus and extension/flexion, respectively. In plastic tests, loading was in a varus direction to determine the constructs’ resistance to varus collapse. In elastic tests, both construct types had higher peak load and stiffness in extension/flexion than varus/valgus. Fx plate constructs were significantly stiffer than PHILOS constructs in varus/valgus (mean: 7.590/6.900 vs. 6.609/6.091 N/mm; p < 0.001 for both) but significantly less stiff in extension/flexion (8.770/9.541 vs. 9.533/9.997 N/mm; p < 0.001 for extension, p < 0.05 for flexion). In varus plastic tests, significantly higher peak loads were reported for Fx plate than PHILOS (134.391 vs. 115.531 N; p < 0.001). In this fracture gap model, humeri implanted with a novel Fx plate provided higher varus/valgus stiffness but lower extension/flexion stiffness than a more traditional proximal humeral locking plate design (PHILOS).