Influence of response-time limits on automated hearing threshold determination
Authors:
- 28 August 2023
- journal article
- research article
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 63 (8) , 1-6
Abstract
ObjectiveIn automated hearing threshold determination procedures, prespecified response- time limits can be applied to evaluate whether a stimulus was truly heard by checking whether the test subject reacts to the onset and the offset of the stimuli within given time intervals. The influence of different response-time limits on the threshold of normal-hearing test subjects was investigated.DesignTwo-stage hearing threshold level measurements applying the ISO 8253-1 (2010) bracketing procedure were performed. Pre-tests at 125 Hz and 1000 Hz were carried out with maximum accepted response times of 600 ms, 1000 ms, and 1200 ms. Subsequently, thresholds were measured at the seven octaves between 125 Hz and 8000 Hz with maximum accepted response times of 600 ms and 1000 ms.Study sample15 test subjects in pre-tests, 25 test subjects in the main study.ResultsThreshold levels determined with a maximum accepted response time of 1000 ms are 2.6 dB lower than those obtained with a maximum accepted response time of 600 ms (95% CI -1.6 dB to 6.9 dB). The threshold shift was similar at all frequencies.ConclusionsBased on this study, response-time limits after both stimulus onset and offset of at least 1000 ms are recommended.Keywords
This publication has 14 references indexed in Scilit:
- Developing Bayesian adaptive methods for estimating sensitivity thresholds (d′) in Yes-No and forced-choice tasksFrontiers in Psychology, 2015
- Validity of Automated Threshold AudiometryEar & Hearing, 2013
- Equivalent threshold sound pressure levels (ETSPL) for Interacoustics DD 45 supra-aural audiometric earphonesInternational Journal of Audiology, 2010
- AMTAS®: Automated method for testing auditory sensitivity: Validation studiesInternational Journal of Audiology, 2010
- Equivalent threshold sound pressure levels (ETSPL) for Sennheiser HDA 280 supra-aural audiometric earphones in the frequency range 125 Hz to 8000 Hz.International Journal of Audiology, 2009
- Reaktionszeiten an der Hörschwelle: Eine Gegenüberstellung von normakusischen und hörgeschädigten Probanden*Laryngo-Rhino-Otologie, 1996
- Reaktionszeiten und Fehlverhalten während der Ermittlung der Tonhörschwelle*Laryngo-Rhino-Otologie, 1981
- Reaktionszeitmessung in der TonaudiometrieEuropean Archives of Oto-Rhino-Laryngology, 1979
- Reaction time procedure for measurement of hearing. II. Threshold functionsThe Journal of the Acoustical Society of America, 1975
- Computer AudiometryJournal of Speech and Hearing Research, 1974