Marion Ute Bug
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Marion Ute Bug has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Hans Rabus
Physikalisch-Technische Bundesanstalt (PTB), Berlin, Germany
5 shared publications - Anatoly B. Rosenfeld
Centre for Medical Radiation Physics, University of Wollongong
3 shared publications - Elisabetta Gargioni
Department of Radiotherapy and Radiation Oncology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
2 shared publications Melina Strüp
Physikalisch-Technische Bundesanstalt, Braunschweig, Germany
2 shared publications- Sebastien Incerti
Université de Bordeaux
2 shared publications Thomas Fedtke
Physikalisch-Technische Bundesanstalt, Braunschweig, Germany
2 shared publications
Latest Publications
- 28 August 2023
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 63 (8) , 1-6
Influence of response-time limits on automated hearing threshold determination
ObjectiveIn automated hearing threshold determination procedures, prespecified response- time limits can be applied to evaluate whether a stimulus was truly heard by checking whether the test subject reacts to the onset and the offset of the stimuli within given time intervals. The influence of different response-time limits on the threshold of normal-hearing test subjects was investigated.DesignTwo-stage hearing threshold level measurements applying the ISO 8253-1 (2010) bracketing procedure were performed. Pre-tests at 125 Hz and 1000 Hz were carried out with maximum accepted response times of 600 ms, 1000 ms, and 1200 ms. Subsequently, thresholds were measured at the seven octaves between 125 Hz and 8000 Hz with maximum accepted response times of 600 ms and 1000 ms.Study sample15 test subjects in pre-tests, 25 test subjects in the main study.ResultsThreshold levels determined with a maximum accepted response time of 1000 ms are 2.6 dB lower than those obtained with a maximum accepted response time of 600 ms (95% CI -1.6 dB to 6.9 dB). The threshold shift was similar at all frequencies.ConclusionsBased on this study, response-time limits after both stimulus onset and offset of at least 1000 ms are recommended.
- 28 August 2023
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 63 (8) , 1-6
Influence of response-time limits on automated hearing threshold determination
ObjectiveIn automated hearing threshold determination procedures, prespecified response- time limits can be applied to evaluate whether a stimulus was truly heard by checking whether the test subject reacts to the onset and the offset of the stimuli within given time intervals. The influence of different response-time limits on the threshold of normal-hearing test subjects was investigated.DesignTwo-stage hearing threshold level measurements applying the ISO 8253-1 (2010) bracketing procedure were performed. Pre-tests at 125 Hz and 1000 Hz were carried out with maximum accepted response times of 600 ms, 1000 ms, and 1200 ms. Subsequently, thresholds were measured at the seven octaves between 125 Hz and 8000 Hz with maximum accepted response times of 600 ms and 1000 ms.Study sample15 test subjects in pre-tests, 25 test subjects in the main study.ResultsThreshold levels determined with a maximum accepted response time of 1000 ms are 2.6 dB lower than those obtained with a maximum accepted response time of 600 ms (95% CI -1.6 dB to 6.9 dB). The threshold shift was similar at all frequencies.ConclusionsBased on this study, response-time limits after both stimulus onset and offset of at least 1000 ms are recommended.
- 23 September 2022
- Published by Elsevier in Physica Medica
- Vol. 102, 103-109
Intercomparison of nanodosimetric distributions in nitrogen simulated with Geant4 and PTra track structure codes
- 23 September 2022
- Published by Elsevier in Physica Medica
- Vol. 102, 103-109
Intercomparison of nanodosimetric distributions in nitrogen simulated with Geant4 and PTra track structure codes
- Open Access
- 1 July 2022
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 152 (1) , 163-171
Dependence of binaural gain for infrasound on interaural phase difference
Increasing complaints about infrasound have generated interest in understanding its perception, including binaural effects. This study investigated the level difference between monaural and binaural presentation required for detection and equal loudness (binaural gain) for pure tones with frequencies of 8, 32, and 400 Hz and an 8 Hz sinusoidally amplitude-modulated tone with diotic 400 Hz carrier. Monaural stimuli were compared to binaural stimuli with interaural phase differences (IPDs) of 0°, 90°, and 180° in two experiments: absolute threshold measurements and loudness matching at 40 phons. The latter was repeated with transposed tones (400 Hz carrier multiplied by a half-wave-rectified 8 Hz sinusoid). When expressed as differences in sound pressure level, similar binaural gain was found across all stimulus types under the diotic condition. Confirming previous studies, the gain was larger at supra-threshold levels (40 phons) than at threshold. However, when the loudness-matching results were expressed as binaural gain with respect to the loudness level, they became 17.5, 11.2, and 5.8 phons for the 8, 32, and 400 Hz stimuli, respectively. Results for the 8 Hz pure tone and the transposed stimulus were IPD dependent.
- 1 July 2022
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 152 (1) , 163-171
Open AccessDependence of binaural gain for infrasound on interaural phase difference
Increasing complaints about infrasound have generated interest in understanding its perception, including binaural effects. This study investigated the level difference between monaural and binaural presentation required for detection and equal loudness (binaural gain) for pure tones with frequencies of 8, 32, and 400 Hz and an 8 Hz sinusoidally amplitude-modulated tone with diotic 400 Hz carrier. Monaural stimuli were compared to binaural stimuli with interaural phase differences (IPDs) of 0°, 90°, and 180° in two experiments: absolute threshold measurements and loudness matching at 40 phons. The latter was repeated with transposed tones (400 Hz carrier multiplied by a half-wave-rectified 8 Hz sinusoid). When expressed as differences in sound pressure level, similar binaural gain was found across all stimulus types under the diotic condition. Confirming previous studies, the gain was larger at supra-threshold levels (40 phons) than at threshold. However, when the loudness-matching results were expressed as binaural gain with respect to the loudness level, they became 17.5, 11.2, and 5.8 phons for the 8, 32, and 400 Hz stimuli, respectively. Results for the 8 Hz pure tone and the transposed stimulus were IPD dependent.
- 15 December 2021
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 61 (7) , 615-620
Free-field correction values for RadioEar DD65v2 circumaural audiometric headphones
Free-field correction values were measured for RadioEar DD65v2 audiometric headphones. Free-field correction values, that is, the difference GF-GC between the free-field sensitivity level GF and the ear simulator sensitivity level GC, were determined by loudness level comparisons between the headphone and a plane progressive wave in a free sound field. The study was based on 17 otologically normal test subjects. Frequency-dependent free-field correction values are provided. The free-field correction of the speech level was determined to be 3.2 dB. Free-field correction values were determined for RadioEar DD65v2 audiometric headphones with an expanded measurement uncertainty.
- 15 December 2021
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 61 (7) , 615-620
Free-field correction values for RadioEar DD65v2 circumaural audiometric headphones
Free-field correction values were measured for RadioEar DD65v2 audiometric headphones. Free-field correction values, that is, the difference GF-GC between the free-field sensitivity level GF and the ear simulator sensitivity level GC, were determined by loudness level comparisons between the headphone and a plane progressive wave in a free sound field. The study was based on 17 otologically normal test subjects. Frequency-dependent free-field correction values are provided. The free-field correction of the speech level was determined to be 3.2 dB. Free-field correction values were determined for RadioEar DD65v2 audiometric headphones with an expanded measurement uncertainty.
- 31 July 2020
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 59 (8) , 624-630
Equivalent threshold sound pressure levels (ETSPLs) for RadioEar DD65v2 circumaural audiometric headphones
Objective: Equivalent threshold sound pressure levels (ETSPLs) were determined for RadioEar DD65v2 audiometric headphones. Design: The pure-tone hearing threshold levels were measured for 11 audiometric frequencies between 0.125 and 8 kHz, according to the conditions specified in ISO 389-9. ETSPLs are provided for an ear simulator according to IEC 60318-1, complemented by a comprehensive uncertainty budget. Study sample: The study was based on 25 otologically normal test subjects. Results: ETSPL values are provided with expanded measurement uncertainty. The data are compared for left/right ears as well as male/female test subjects. Conclusions: The results of both studies may be used to update ISO 389-8, the RETSPL standard for circumaural audiometric headphones.
- 31 July 2020
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 59 (8) , 624-630
Equivalent threshold sound pressure levels (ETSPLs) for RadioEar DD65v2 circumaural audiometric headphones
Objective: Equivalent threshold sound pressure levels (ETSPLs) were determined for RadioEar DD65v2 audiometric headphones. Design: The pure-tone hearing threshold levels were measured for 11 audiometric frequencies between 0.125 and 8 kHz, according to the conditions specified in ISO 389-9. ETSPLs are provided for an ear simulator according to IEC 60318-1, complemented by a comprehensive uncertainty budget. Study sample: The study was based on 25 otologically normal test subjects. Results: ETSPL values are provided with expanded measurement uncertainty. The data are compared for left/right ears as well as male/female test subjects. Conclusions: The results of both studies may be used to update ISO 389-8, the RETSPL standard for circumaural audiometric headphones.
- 7 August 2014
- Published by Springer Nature in The European Physical Journal D
- Vol. 68 (8) , 217
Nanodosimetric characterization of ion beams
- 7 August 2014
- Published by Springer Nature in The European Physical Journal D
- Vol. 68 (8) , 217
Nanodosimetric characterization of ion beams
- 8 December 2013
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 161 (1-4) , 474-477
Proton-impact ionisation cross sections for nanodosimetric track structure simulations
Monte Carlo simulations of the particle track structure require accurate ion- and electron-impact cross-section data of the medium. These data are scarce and often inconsistent when measured by different groups. In this work, literature data on ionisation cross sections (CSs) of nitrogen and propane for protons with energies 0.1–10 MeV are reviewed and implemented in the code PTra. Methane data were used to obtain proton-impact CSs of propane due to their absence in the literature. PTra is benchmarked by comparing simulated particle-track parameters to experimental results, measured with an ion-counting nanodosemeter.
- 8 December 2013
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 161 (1-4) , 474-477
Proton-impact ionisation cross sections for nanodosimetric track structure simulations
Monte Carlo simulations of the particle track structure require accurate ion- and electron-impact cross-section data of the medium. These data are scarce and often inconsistent when measured by different groups. In this work, literature data on ionisation cross sections (CSs) of nitrogen and propane for protons with energies 0.1–10 MeV are reviewed and implemented in the code PTra. Methane data were used to obtain proton-impact CSs of propane due to their absence in the literature. PTra is benchmarked by comparing simulated particle-track parameters to experimental results, measured with an ion-counting nanodosemeter.
- 27 November 2012
- Published by Springer Nature in The European Physical Journal D
- Vol. 66 (11) , 1-6
Nanoscale characterization of ion tracks: MC simulations versus analytical approach
- 27 November 2012
- Published by Springer Nature in The European Physical Journal D
- Vol. 66 (11) , 1-6
Nanoscale characterization of ion tracks: MC simulations versus analytical approach
- 21 September 2011
- Published by Taylor & Francis in International Journal of Radiation Biology
- Vol. 88 (1-2) , 137-142
Simulation of ionisation clusters formed in nanometric volumes of the deoxyribose-substitute tetrahydrofuran
Purpose: To investigate the implications of using interaction cross sections of liquid water for the target volume when studying radiation action at the DNA level by particle track structure simulations. Materials and methods: Absolute interaction cross sections for low energy electrons between 20 eV and 1 keV were measured for tetrahydrofuran (THF), which is a substitute for deoxyribose. From these data a complete interaction cross section data set was derived and integrated in our PTB Track structure Monte Carlo code ‘PTra’. Simulations of electron track structure in THF and water were performed and ionisation cluster size distributions in nanometric target volumes were determined. From these a nanodosimetric estimate for the probability to produce a double strand break was derived. Results: The probability distribution of ionisation cluster sizes was found to be shifted towards smaller values for a THF-filled target as compared to a water-filled one. For all electron energies investigated, the nanodosimetric estimates for double-strand break probability in the THF-filled target have lower values than for a target of liquid water. Conclusion: The preliminary results indicate that simulations based on cross sections of water would overestimate the initial direct radiation damage to the DNA.
- 21 September 2011
- Published by Taylor & Francis in International Journal of Radiation Biology
- Vol. 88 (1-2) , 137-142
Simulation of ionisation clusters formed in nanometric volumes of the deoxyribose-substitute tetrahydrofuran
Purpose: To investigate the implications of using interaction cross sections of liquid water for the target volume when studying radiation action at the DNA level by particle track structure simulations. Materials and methods: Absolute interaction cross sections for low energy electrons between 20 eV and 1 keV were measured for tetrahydrofuran (THF), which is a substitute for deoxyribose. From these data a complete interaction cross section data set was derived and integrated in our PTB Track structure Monte Carlo code ‘PTra’. Simulations of electron track structure in THF and water were performed and ionisation cluster size distributions in nanometric target volumes were determined. From these a nanodosimetric estimate for the probability to produce a double strand break was derived. Results: The probability distribution of ionisation cluster sizes was found to be shifted towards smaller values for a THF-filled target as compared to a water-filled one. For all electron energies investigated, the nanodosimetric estimates for double-strand break probability in the THF-filled target have lower values than for a target of liquid water. Conclusion: The preliminary results indicate that simulations based on cross sections of water would overestimate the initial direct radiation damage to the DNA.
- 26 May 2010
- Published by Springer Nature in The European Physical Journal D
- Vol. 60 (1) , 85-92
Effect of a magnetic field on the track structure of low-energy electrons: a Monte Carlo study
- 26 May 2010
- Published by Springer Nature in The European Physical Journal D
- Vol. 60 (1) , 85-92
Effect of a magnetic field on the track structure of low-energy electrons: a Monte Carlo study