Feasibility of high temporal resolution breast DCE‐MRI using compressed sensing theory
- 27 August 2010
- journal article
- Published by Wiley in Medical Physics
- Vol. 37 (9) , 4971-4981
Abstract
Purpose: To investigate the feasibility of high temporal resolution breast DCE‐MRI using compressed sensing theory.Methods: Two experiments were designed to investigate the feasibility of using reference image based compressed sensing (RICS) technique in DCE‐MRI of the breast. The first experiment examined the capability of RICS to faithfully reconstruct uptake curves using undersampled data sets extracted from fully sampled clinical breast DCE‐MRI data. An average approach and an approach using motion estimation and motion compensation (ME/MC) were implemented to obtain reference images and to evaluate their efficacy in reducing motion related effects. The second experiment, anin vitro phantom study, tested the feasibility of RICS for improving temporal resolution without degrading the spatial resolution.Results: For the uptake‐curve reconstruction experiment, there was a high correlation between uptake curves reconstructed from fully sampled data by Fourier transform and from undersampled data by RICS, indicating high similarity between them. The mean Pearson correlation coefficients for RICS with the ME/MC approach and RICS with the average approach were and , respectively. The comparisons of final reconstruction results between RICS with the average approach and RICS with the ME/MC approach suggested that the latter was superior to the former in reducing motion related effects. For the in vitro experiment, compared to the fully sampled method, RICS improved the temporal resolution by an acceleration factor of 10 without degrading the spatial resolution.Conclusions: The preliminary study demonstrates the feasibility of RICS for faithfully reconstructing uptake curves and improving temporal resolution of breast DCE‐MRI without degrading the spatial resolution.Keywords
Funding Information
- National Institutes of Health (R21 CA118569‐01A1)
This publication has 47 references indexed in Scilit:
- Systolic 3D first-pass myocardial perfusion MRI: Comparison with diastolic imaging in healthy subjectsMagnetic Resonance in Medicine, 2010
- Radial k‐t FOCUSS for high‐resolution cardiac cine MRIMagnetic Resonance in Medicine, 2009
- Undersampled radial MR acquisition and highly constrained back projection (HYPR) reconstruction: Potential medical imaging applications in the post‐Nyquist eraJournal of Magnetic Resonance Imaging, 2009
- Compressed sensing for resolution enhancement of hyperpolarized 13C flyback 3D-MRSIJournal of Magnetic Resonance, 2008
- Removing undersampling artifacts in DCE-MRI studies using independent components analysisMagnetic Resonance in Medicine, 2008
- Improvedk–tBLAST andk–tSENSE using FOCUSSPhysics in Medicine & Biology, 2007
- High frame‐rate simultaneous bilateral breast DCE‐MRIMagnetic Resonance in Medicine, 2006
- New Technologies and Directed Agents for Applications of Cancer ImagingJournal of Clinical Oncology, 2006
- SENSE Imaging of the BreastAmerican Journal of Roentgenology, 2005
- The discovery of angiogenic factors:General Pharmacology: The Vascular System, 2000