YYYongquan Ye

Yongquan Ye

*This is an algorithmically generated author record based on publicly available information.

Yongquan Ye has a total of 133 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Wave‐CAIPI Multiparameter MR Imaging in Neurology

    by Congcong Liu, Yongquan Ye, Yifan Guo, Yihang Zhou, Yanjie Zhu, Xin Liu, Jian Xu, Hairong Zheng, Dong Liang, Haifeng Wang

    In clinical practice, particularly in neurology assessments, imaging multiparametric MR images with a single‐sequence scan is often limited by either insufficient imaging contrast or the constraints of accelerated imaging techniques. A novel single scan 3D imaging method, incorporating Wave‐CAIPI and MULTIPLEX technologies and named WAMP, has been developed for rapid and comprehensive parametric imaging in clinical diagnostic applications. Featuring a hybrid design that includes wave encoding, the CAIPIRINHA sampling pattern, dual time of repetition (TR), dual flip angle (FA), multiecho, and optional flow modulation, the WAMP method captures information on RF B1t fields, proton density (PD), T1, susceptibility, and blood flow. This method facilitates the synthesis of multiple qualitative contrast‐weighted images and relaxometric parametric maps. A single WAMP scan generates multiple contrast‐weighted images and relaxometric parametric maps, including PD‐weighted (PDW), T1‐weighted (T1W), T2*‐weighted (T2W), adjusted T1‐weighted (aT1W), susceptibility‐weighted imaging (SWI), B1t map, T1 map, T2/R2* map, PD map, and quantitative susceptibility mapping (QSM). Both phantom and in vivo experiments have demonstrated that the proposed method can achieve high image quality and quantification accuracy even at high acceleration factors of 4 and 9. The experiments have confirmed that the rapid single scan method can be effectively applied in clinical neurology, serving as a valuable diagnostic tool for conditions such as pediatric tuberous sclerosis complex (TSC)‐related epilepsy, adult Parkinson's disease, and suspected stroke patient. The WAMP method holds substantial potential for advancing multiparametric MR imaging in clinical neurology, promising significant improvements in both diagnostic speed and accuracy.


  • Validation of a Deep Learning‐Based Method for Accelerating Susceptibility‐Weighted Imaging in Clinical Settings

    by Xiao Wu, Shan Xu, Yao Zhang, Yongquan Ye, Deying Zhang, Lei Yu, Ruiting Zhang, Jianzhong Sun, Peiyu Huang

    Susceptibility‐weighted imaging (SWI) has been widely used in clinical contexts, in which the speed of acquisition is frequently a critical issue. In this study, we aim to test the feasibility of a deep learning (DL)‐based reconstruction method for accelerating SWI acquisition in clinical settings. A total of 61 subjects were consecutively enrolled. SWI scans using prospective under‐sampling and DL‐based reconstruction method (acceleration factor = 5, acquisition time: 1:46) and parallel imaging (PI, acceleration factor = 2, acquisition time: 4:45) were acquired from each subject. The DL‐based method utilizes a cascaded convolutional neural network, namely, ReconNet3D, to perform k‐space to image reconstruction with the capacity of single‐channel input and single‐channel output. The DL‐SWI and PI‐SWI results were compared quantitatively using structural similarity index (SSIM) and peak signal‐to‐noise ratio (PSNR). Two raters independently assessed image quality from five aspects: artifacts, noise level, sharpness, lesion conspicuity, and overall image quality. The numbers of microbleeds were also counted. Finally, both sets of images of the same subject were reviewed side‐by‐side for noninferiority assessments. The DL‐SWI images showed good similarity in terms of SSIM (mean ± SD: 0.89 ± 0.02) and PSNR (mean ± SD: 36.91 ± 2.41) with PI‐SWI. In comparison, DL‐SWI images had significantly better scores in terms of artifacts, noise, and overall image quality score (4.15 vs. 3.33; 3.85 vs. 3.16; 3.85 vs. 3.44, all with p < 0.001). DL‐SWI showed reduced image sharpness (p = 0.031), but no significant difference regarding lesion conspicuity. The number of microbleeds identified from the DL‐SWI images completely matched the PI‐SWI results. We had not observed any false‐negative or false‐positive readings on DL‐SWI images. The DL‐based SWI acceleration method could significantly reduce scan time and maintain image quality, suggesting its great potential in clinical applications.


  • Complex multi-dimensional integration for T2* and R2* mapping

    by Yongquan Ye, Jian Xu, Zhongqi Zhang, Yan Zhang, Qiang Zhao, Jiajia Xu, Huishu Yuan


  • Highly Accelerated Multiple Parametric MR Imaging with Wave-CAIPI and MULTIPLEX

    by Haifeng Wang, Yongquan Ye, Congcong Liu, Jingyuan Lv, Zhilang Qiu, Xin Liu, Jian Xu, Dong Liang, Hairong Zheng

    A novel single-scan hybrid 3D imaging method using Wave-CAIPI and MULTIPLEX technologies, named as WAMP, is proposed for 3D high-resolution rapid imaging. One single scan of the proposed rapid imaging method not only generates simultaneous B1t and T1 maps, but also qualitative images of T1W, PDW, T2*W, augmented T1W (aT1W), SWI and MRA, as well as parametric maps of T2* (R2*), PD and QSM. The in vivo experiments have showed that the proposed method could rapidly achieve high image quality and high quantification accuracy at the high acceleration factors in clinical applications.

  • Erratum to: MULTI‐parametric MR imaging with fLEXible design (MULTIPLEX) (Magn Reson Med. 2021;87:658–673)

    by Yongquan Ye, Jingyuan Lyu, Yichen Hu, Zhongqi Zhang, Jian Xu, Weiguo Zhang

  • Augmented T1‐weighted steady state magnetic resonance imaging

    by Yongquan Ye, Jingyuan Lyu, Yichen Hu, Zhongqi Zhang, Jian Xu, Weiguo Zhang, Jianmin Yuan, Chao Zhou, Wei Fan, Xu Zhang

    T1 contrasts obtained using short‐TR incoherent steady state gradient echo (GRE) methods are generally suboptimal, to which non‐T1 factors in the signals play a major part. In this work, we proposed an augmented T1‐weighted (aT1W) method to extract the signal ratio between routine GRE T1W and proton density‐weighted signals that effectively removes the non‐T1 effects from the original T1W signals, including proton density, T2* decay, and coil sensitivity. A recently proposed multidimensional integration (MDI) technique was incorporated in the aT1W calculation for better signal‐to‐noise ratio (SNR) performance. For comparison between aT1W and T1W results, Monte Carlo noise analysis was performed via simulation and on scanned data, and region‐of‐interest (ROI) analysis and comparison was performed on the system phantom. For brain scans, the image contrast, noise behavior, and SNR of aT1W images were compared with routine GRE and inversion‐recovery–based T1W images. The proposed aT1W method yielded saliently improved T1 contrasts (potentially > 30% higher contrast‐to‐noise ratio [CNR]) than routine GRE T1W images. Good spatial homogeneity and signal consistency as well as high SNR/CNR were achieved in aT1W images using the MDI technique. For contrast‐enhanced (CE) imaging, aT1W offered stronger post‐CE contrast and better boundary delineation than T1 MPRAGE images while using a shorter scan time.


  • MULTI‐parametric MR imaging with fLEXible design (MULTIPLEX)

    by Yongquan Ye, Jingyuan Lyu, Yichen Hu, Zhongqi Zhang, Jian Xu, Weiguo Zhang

    Purpose: To introduce a gradient echo (GRE) ‐based method, namely MULTIPLEX, for single‐scan 3D multi‐parametric MRI with high resolution, signal‐to‐noise ratio (SNR), accuracy, efficiency, and acquisition flexibility.Theory: With a comprehensive design with dual‐repetition time (TR), dual flip angle (FA), multi‐echo, and optional flow modulation features, the MULTIPLEX signals contain information on radiofrequency (RF) B1t fields, proton density, T1, susceptibility and blood flows, facilitating multiple qualitative images and parametric maps.Methods: MULTIPLEX was evaluated on system phantom and human brains, via visual inspection for image contrasts and quality or quantitative evaluation via simulation, phantom scans and literature comparison. Region‐of‐interest (ROI) analysis was performed on parametric maps of the system phantom and brain scans, extracting the mean and SD of the T1, , proton density (PD), and/or quantitative susceptibility mapping (QSM) values for comparison with reference values or literature.Results: One MULTIPLEX scan offers multiple sets of images, including but not limited to: composited PDW/T1W/W, aT1W, SWI, MRA (optional), B1t map, T1 map, / maps, PD map, and QSM. The quantitative error of phantom T1, and PD mapping were 3) whole brain coverage were about 7.5 min, while processing times were <1 min. With flow modulation, additional MRA images can be obtained without affecting the quality or accuracy of other images.Conclusion: The proposed MUTLIPLEX method possesses great potential for multi‐parametric MR imaging.


  • Open Access

    Accelerating 3D MULTIPLEX MRI Reconstruction with Deep Learning

    by Eric Z. Chen, Yongquan Ye, Xiao Chen, Jingyuan Lyu, Zhongqi Zhang, Yichen Hu, Terrence Chen, Jian Xu, Shanhui Sun

    Multi-contrast MRI images provide complementary contrast information about the characteristics of anatomical structures and are commonly used in clinical practice. Recently, a multi-flip-angle (FA) and multi-echo GRE method (MULTIPLEX MRI) has been developed to simultaneously acquire multiple parametric images with just one single scan. However, it poses two challenges for MULTIPLEX to be used in the 3D high-resolution setting: a relatively long scan time and the huge amount of 3D multi-contrast data for reconstruction. Currently, no DL based method has been proposed for 3D MULTIPLEX data reconstruction. We propose a deep learning framework for undersampled 3D MRI data reconstruction and apply it to MULTIPLEX MRI. The proposed deep learning method shows good performance in image quality and reconstruction time.

  • A multi‐dimensional integration (MDI) strategy for MR T2* mapping

    by Yongquan Ye, Jingyuan Lyu, Wenbo Sun, Lan Lan, Liang Wang, Weiguo Zhang, Haibo Xu

    MRI signals are intrinsically multi‐dimensional, and signal behavior may be orthogonal among different dimensions. Such dimensional orthogonality can be utilized to eliminate unwanted effects and facilitate mathematical simplicity during image processing for improved outcomes. In this work, we will demonstrate and analyze the principles and performance of a newly developed multi‐dimensional integration (MDI) strategy in MR T2* mapping. By constructing a complex signal function to extract the inter‐echo signal changes, MDI solves an optimization problem by processing all signal dimensions (eg echoes, flip angles and coil channels) in one integrative step. MDI was compared with routine curve fitting methods on noise behavior, quantification accuracy and computational efficiency. All methods were tested and compared on simulation, phantom and knee data. Monte Carlo simulations were performed on simulation and all MRI data to investigate noise propagation from k space to T2* maps. For phantom tests, T2* values in regions of interest were extracted on a voxel‐wise basis and analyzed using a paired t‐test between scanning parameters and mapping methods, with p < 0.05 being significantly different. MDI facilitated a straightforward processing procedure, yielding homogeneous, high‐signal‐to‐noise‐ratio (SNR) and artifact‐free T2* maps without explicit coil combination or additional measures. Compared with routine fitting methods, MDI offered significantly (p < 0.05) improved SNR and quantitative accuracy/robustness, with two to three orders higher computational efficiency. MDI also represented low‐SNR signals with low T2* values, avoiding misinterpretation with long‐T2* species.


  • Seed prioritized unwrapping (SPUN) for MR phase imaging

    by Yongquan Ye, Fei Zhou, Jinguang Zong, Jingyuan Lyu, Yanling Chen, Shuheng Zhang, Weiguo Zhang, Qiang He, Xueping Li, Ming Li, et al.

    Background: Region‐growing‐based phase unwrapping methods have the potential for lossless phase aliasing removal, but generally suffer from unwrapping error propagation associated with discontinuous phase and/or long calculation times. The tradeoff point between robustness and efficiency of phase unwrapping methods in the region‐growing category requires improvement.Purpose: To demonstrate an accurate, robust, and efficient region‐growing phase unwrapping method for MR phase imaging applications.Study Type: Prospective.Subjects, Phantom: normal human subjects (10) / brain surgery patients (2) / water phantoms / computer simulation.Field Strength/Sequence: 3 T/gradient echo sequences (2D and 3D).Assessment: A seed prioritized unwrapping (SPUN) method was developed based on single‐region growing, prioritizing only a portion (eg, 100 seeds or 1% seeds) of available seed voxels based on continuity quality during each region‐growing iteration. Computer simulation, phantom, and in vivo brain and pelvis scans were performed. The error rates, seed percentages, and calculation times were recorded and reported. SPUN unwrapped phase images were visually evaluated and compared with Laplacian unwrapped results.Statistical Tests: Monte Carlo simulation was performed on a 3D dipole phase model with a signal‐to‐noise ratio (SNR) of 1–9 dB, to obtain the mean and standard deviation of calculation error rates and calculation times.Results: Simulation revealed a very robust unwrapping performance of SPUN, reaching an error rate of sp = 1 or 10 voxels for 2D and Nsp = 1% for 3D data.Data Conclusion: SPUN offers very robust and fast region‐growing‐based phase unwrapping, and does not require any tissue masking or segmentation, nor poses a limitation over imaging parameters.Level of Evidence: 3Technical Efficacy: Stage 1J. Magn. Reson. Imaging 2019;50:62–70.