Unity-Power-Factor Control Based on Precise Ripple Cancellation for Fast-Response PFC Preregulator
Authors:
- 6 July 2015
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 31 (4) , 3324-3337
Abstract
Power-factor preregulators are commonly used in electronic equipments for minimizing the injection of current harmonics into the mains power line. However, the bandwidth of conventional preregulators are usually configured to be very small in order to achieve near-unity power factor, and this inevitably gives rise to poor dynamic response. Ripple estimation/cancellation method is used to eliminate the double-line frequency component from the sampled output voltage before it propagates into the voltage control loop, hence, the requirement of small bandwidth is not mandatory. The existing ripple estimation circuits, however, are only accurate under specific conditions, beyond which power factor will be degraded. In view of this, a new ripple estimation/cancellation network consisting of an amplitude tuner and a phase shifter based on switched-resistor circuits is proposed and verified experimentally on a 200-W boost power-factor preregulator. It is shown that the proposed ripple estimation network not only provides accurate ripple estimation over a wide range of operating conditions, it also gives a way to decouple the power factor of a preregulator from its controller bandwidth. With the aid of the proposed ripple estimation network, the desired features of fast dynamic response and unity power factor are both achieved.Keywords
Funding Information
- University Grants Committee
- Hong Kong Special Administrative Region
- Research Grants Council
- General Research Fund (GRF) Scheme (PolyU 5193/10, PolyU 15210714)
This publication has 13 references indexed in Scilit:
- A Novel PCCM Boost PFC Converter With Fast Dynamic ResponseIEEE Transactions on Industrial Electronics, 2010
- On the Maximum Bandwidth Attainable by Power Factor Correctors With a Standard CompensatorIEEE Transactions on Industry Applications, 2010
- A Unified Approach for the Derivation of Robust Control for Boost PFC ConvertersIEEE Transactions on Power Electronics, 2009
- Steady-State Analysis and Modeling of Power Factor Correctors With Appreciable Voltage Ripple in the Output-Voltage Feedback Loop to Achieve Fast Transient ResponseIEEE Transactions on Power Electronics, 2009
- A Simple Method to Improve the Dynamic Response of Single-Phase PWM RectifiersIEEE Transactions on Industrial Electronics, 2008
- A Unity Power Factor Correction Preregulator With Fast Dynamic Response Based on a Low-Cost MicrocontrollerIEEE Transactions on Power Electronics, 2008
- A Control Circuit With Load-Current Injection for Single-Phase Power-Factor-Correction RectifiersIEEE Industrial Electronics Magazine, 2007
- Self-tuning digitally controlled low-harmonic rectifier having fast dynamic responseIEEE Transactions on Power Electronics, 2003
- Fast controller design for single-phase power-factor correction systemsIEEE Transactions on Industrial Electronics, 1997
- Fast-response high-quality rectifier with sliding mode controlIEEE Transactions on Power Electronics, 1994