Validation of a New Method for Stroke Volume Variation Assessment: a Comparaison with the PiCCO Technique
Preprint
Abstract
This paper proposes a novel, simple and minimally invasive method for stroke volume variation assessment using arterial blood pressure measurements. The arterial blood pressure signal is reconstructed using a semi-classical signal analysis method allowing the computation of a parameter, called the first systolic invariant INVS1. We show that INVS1 is linearly related to stroke volume. To validate this approach, a statistical comparaison between INVS1 and stroke volume measured with the PiCCO technique was performed during a 15-mn recording in 21 mechanically ventilated patients in intensive care. In 94% of the whole recordings, a strong correlation was estimated by cross-correlation analysis (mean coefficient=0.9) and linear regression (mean coefficient=0.89). Once the linear relation had been verified, a Bland-Altman test showed the very good agreement between the two approaches and their interchangeability. For the remaining 6%, INVS1 and the PiCCO stroke volume were not correlated at all, and this discrepancy, interpreted with the help of mean pressure, heart rate and peripheral vascular resistances, was in favor of INVS1.Keywords
All Related Versions
This publication has 19 references indexed in Scilit:
- Evaluation of stroke volume variation obtained by arterial pulse contour analysis to predict fluid responsiveness intraoperativelyBritish Journal of Anaesthesia, 2009
- Lithium dilution cardiac output measurement in the critically ill patient: determination of precision of the techniqueIntensive Care Medicine, 2008
- A reduced model of pulsatile flow in an arterial compartmentChaos, Solitons & Fractals, 2007
- Separation of arterial pressure into a nonlinear superposition of solitary waves and a windkessel flowBiomedical Signal Processing and Control, 2007
- Estimating cardiac output from arterial blood pressurewaveforms: a critical evaluation using the MIMIC II database2005
- The validity of trans-esophageal Doppler ultrasonography as a measure of cardiac output in critically ill adultsIntensive Care Medicine, 2004
- Comparison of esophageal Doppler, pulse contour analysis, and real-time pulmonary artery thermodilution for the continuous measurement of cardiac outputJournal of Cardiothoracic and Vascular Anesthesia, 2004
- Estimation of changes in cardiac output from the arterial blood pressure waveform in the upper limb,British Journal of Anaesthesia, 2001
- Continuous noninvasive measurement of aortic blood flow in critically ill patients with a new esophageal echo-Doppler systemJournal of Critical Care, 1998
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986