Yves Papelier
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yves Papelier has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Andry Van de Louw
Service de réanimation polyvalente, centre hospitalier Sud-Francilien, site d’Évry, Évry, France
2 shared publications - Claire Médigue
INRIA-Rocquencourt
2 shared publications - François Cottin
Université Paris-Saclay, Inria, CIAMS, Gif-sur-Yvette, France
2 shared publications - Taous-Meriem Laleg-Kirati
The National Institute for Research in Digital Science and Technology, Paris-Saclay, France
2 shared publications - Carlo D'Angelo
EPFL/SB/IACS/CMCS, Ecole Polytechnique Fédérale de Lausanne (Switzerland)
1 shared publication
Latest Publications
- 8 July 2010
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 38 (12) , 3618-3629
Validation of a Semi-Classical Signal Analysis Method for Stroke Volume Variation Assessment: A Comparison with the PiCCO Technique
This study proposes a Semi-Classical Signal Analysis (SCSA) method for stroke volume (SV) variations assessment from arterial blood pressure measurements. One of the SCSA parameters, the first systolic invariant (INVS1), has been shown to be linearly related to SV. To technically validate this approach, the comparison between INVS1 and SV measured with the currently used PiCCO technique was performed during a 15-min recording in 20 mechanically ventilated patients in intensive care. A strong correlation was estimated by linear regression and cross-correlation analysis (mean coefficient = 0.90 ± 0.01 SEM at the two tests).
- 8 July 2010
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 38 (12) , 3618-3629
Validation of a Semi-Classical Signal Analysis Method for Stroke Volume Variation Assessment: A Comparison with the PiCCO Technique
This study proposes a Semi-Classical Signal Analysis (SCSA) method for stroke volume (SV) variations assessment from arterial blood pressure measurements. One of the SCSA parameters, the first systolic invariant (INVS1), has been shown to be linearly related to SV. To technically validate this approach, the comparison between INVS1 and SV measured with the currently used PiCCO technique was performed during a 15-min recording in 20 mechanically ventilated patients in intensive care. A strong correlation was estimated by linear regression and cross-correlation analysis (mean coefficient = 0.90 ± 0.01 SEM at the two tests).
- Open Access
Validation of a New Method for Stroke Volume Variation Assessment: a Comparaison with the PiCCO Technique
This paper proposes a novel, simple and minimally invasive method for stroke volume variation assessment using arterial blood pressure measurements. The arterial blood pressure signal is reconstructed using a semi-classical signal analysis method allowing the computation of a parameter, called the first systolic invariant INVS1. We show that INVS1 is linearly related to stroke volume. To validate this approach, a statistical comparaison between INVS1 and stroke volume measured with the PiCCO technique was performed during a 15-mn recording in 21 mechanically ventilated patients in intensive care. In 94% of the whole recordings, a strong correlation was estimated by cross-correlation analysis (mean coefficient=0.9) and linear regression (mean coefficient=0.89). Once the linear relation had been verified, a Bland-Altman test showed the very good agreement between the two approaches and their interchangeability. For the remaining 6%, INVS1 and the PiCCO stroke volume were not correlated at all, and this discrepancy, interpreted with the help of mean pressure, heart rate and peripheral vascular resistances, was in favor of INVS1.
Open AccessValidation of a New Method for Stroke Volume Variation Assessment: a Comparaison with the PiCCO Technique
This paper proposes a novel, simple and minimally invasive method for stroke volume variation assessment using arterial blood pressure measurements. The arterial blood pressure signal is reconstructed using a semi-classical signal analysis method allowing the computation of a parameter, called the first systolic invariant INVS1. We show that INVS1 is linearly related to stroke volume. To validate this approach, a statistical comparaison between INVS1 and stroke volume measured with the PiCCO technique was performed during a 15-mn recording in 21 mechanically ventilated patients in intensive care. In 94% of the whole recordings, a strong correlation was estimated by cross-correlation analysis (mean coefficient=0.9) and linear regression (mean coefficient=0.89). Once the linear relation had been verified, a Bland-Altman test showed the very good agreement between the two approaches and their interchangeability. For the remaining 6%, INVS1 and the PiCCO stroke volume were not correlated at all, and this discrepancy, interpreted with the help of mean pressure, heart rate and peripheral vascular resistances, was in favor of INVS1.
- Open Access
- 23 September 2005
- Published by EDP Sciences in ESAIM: Proceedings
- Vol. 14, 72-88
Mathematical modelling of the cardiovascular system and skeletal muscle interaction during exercise
ESAIM: Proceedings and Surveys publishes the proceedings of colloquia, seminars, summer schools, etc., in all areas of applied mathematics
- 23 September 2005
- Published by EDP Sciences in ESAIM: Proceedings
- Vol. 14, 72-88
Open AccessMathematical modelling of the cardiovascular system and skeletal muscle interaction during exercise
ESAIM: Proceedings and Surveys publishes the proceedings of colloquia, seminars, summer schools, etc., in all areas of applied mathematics