Measurement of gastric emptying in man using deuterated octanoic acid
- 13 December 2001
- journal article
- research article
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 16 (2) , 127-133
Abstract
Gamma scintigraphy is considered the gold standard for the measurement of gastric emptying in humans. Recently, it has been proposed that a [ 13 C]octanoate breath test can be used as an alternative technique for measuring gastric emptying of the solid phase, but the results from the two methods are not directly equivalent since in the breath test the label is subject to post‐absorptive processing and consequently the emptying functions cannot be observed directly. This work investigates an alternative stable isotope method using deuterated octanoate where the kinetics of redistribution between and elimination from the various body pools are much more easily modelled. Gastric emptying was studied in healthy human volunteers by simultaneous measurement using both [ 13 C]octanoate and [ 2 H]octanoate as well as gamma scintigraphy. Comparison of the gastric emptying functions from the deuterium method and scintigraphy indicated that the two methods gave equivalent results. The new method can therefore be used in populations considered too vulnerable to ionising radiation to allow gamma scintigraphy to be performed, or as a proxy gold standard in laboratories where scintigraphic methods are unavailable, allowing further comparisons with the breath test method to be made to validate the latter in different population groups. Copyright© 2001 John Wiley & Sons, Ltd.Keywords
This publication has 16 references indexed in Scilit:
- On-line determination of the deuterium abundance in breath water vapour by flowing afterglow mass spectrometry with applications to measurements of total body waterRapid Communications in Mass Spectrometry, 2000
- A valid, accurate, office based non-radioactive test for gastric emptying of solidsGut, 2000
- Validation of the [1,2‐13C]acetate recovery factor for correction of [U‐13C]palmitate oxidation rates in humansThe Journal of Physiology, 1998
- Significance of Diagnostic Parameters in [13C]Octanoic Acid Gastric Emptying Breath Tests*Isotopes in Environmental and Health Studies, 1998
- ReplyGastroenterology, 1998
- 13C-octanoic acid breath test: Valueless test for gastric emptying?Gastroenterology, 1998
- Kinetics of13CO2elimination after ingestion of13C bicarbonate: the effects of exercise and acid base balanceEuropean Journal of Clinical Investigation, 1994
- Measurement of gastric emptying rate of solids by means of a carbon-labeled octanoic acid breath testGastroenterology, 1993
- Biphasic nature of gastric emptying.Gut, 1988
- Gastric emptying in normal subjects--a reproducible technique using a single scintillation camera and computer system.Gut, 1983