Leslie J. C. Bluck
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Leslie J. C. Bluck has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
Allan T. Clapperton
Medical Research Council, Human Nutrition Research, Fulbourn Road, Cambridge CB1 9NL, UK
3 shared publicationsSarah J. Jackson
MRC Human Nutrition Research, MRC Biostatistics Unit, Institute of Public Health, University Forvie Site, Cambridge, UK
3 shared publicationsW. Andy Coward
Medical Research Council, Human Nutrition Research, Fulbourn Road, Cambridge CB1 9NL, UK
3 shared publications- Mario Siervo
Dementia Centre of Excellence, School of Population Health, Curtin University, Perth 6102, Australia
2 shared publications Adrian P. Izzard
Dunn Nutritional Laboratory, Downhams Lane, Milton Road, Cambridge CB4 1XJ, UK
1 shared publication- Adrian P. Mander
Centre for Trials Research, Cardiff University, Cardiff, UK
1 shared publication
Latest Publications
- Open Access
- 31 October 2013
- Published by Wiley in ISRN Endocrinology
- Vol. 2013, 1-7
Insulin Sensitivity Assessed by Stable Isotopes with Oral Glucose Administration: Validation with Euglycaemic Clamp
Methods of determining insulin sensitivity that use an oral challenge of glucose are preferred to those using intravenous administration since the measurement is made in conditions more akin to normal physiology. One previously reported protocol (ODILE) studies glucose uptake in isolation from absorption and endogenous production by the intravenous administration of tracer approximately forty-five minutes after the oral dose is given. However, this methodology has not been validated against other accredited procedures. This study utilizes the euglycemic hyperinsulinemic clamp in order to validate the ODILE method.
- 31 October 2013
- Published by Wiley in ISRN Endocrinology
- Vol. 2013, 1-7
Open AccessInsulin Sensitivity Assessed by Stable Isotopes with Oral Glucose Administration: Validation with Euglycaemic Clamp
Methods of determining insulin sensitivity that use an oral challenge of glucose are preferred to those using intravenous administration since the measurement is made in conditions more akin to normal physiology. One previously reported protocol (ODILE) studies glucose uptake in isolation from absorption and endogenous production by the intravenous administration of tracer approximately forty-five minutes after the oral dose is given. However, this methodology has not been validated against other accredited procedures. This study utilizes the euglycemic hyperinsulinemic clamp in order to validate the ODILE method.
- 1 May 2012
- Published by Elsevier in Metabolism
- Vol. 61 (5) , 680-688
In vivo nitric oxide synthesis, insulin sensitivity, and asymmetric dimethylarginine in obese subjects without and with metabolic syndrome
- 1 May 2012
- Published by Elsevier in Metabolism
- Vol. 61 (5) , 680-688
In vivo nitric oxide synthesis, insulin sensitivity, and asymmetric dimethylarginine in obese subjects without and with metabolic syndrome
- Open Access
- 16 June 2011
- Published by Springer Nature in BMC Pregnancy and Childbirth
- Vol. 11 (1) , 44
Physical activity, sedentary behaviors, and estimated insulin sensitivity and secretion in pregnant and non-pregnant women
Background: Overweight and obesity during pregnancy raise the risk of gestational diabetes and birth complications. Lifestyle factors like physical activity may decrease these risks through beneficial effects on glucose homeostasis. Here we examined physical activity patterns and their relationships with measures of glucose homeostasis in late pregnancy compared to non-pregnant women. Methods: Normal weight and overweight women without diabetes (N = 108; aged 25-35 years) were studied; 35 were pregnant (in gestational weeks 28-32) and 73 were non-pregnant. Insulin sensitivity and β-cell response were estimated from an oral glucose tolerance test. Physical activity was measured during 10-days of free-living using a combined heart rate sensor and accelerometer. Total (TEE), resting (REE), and physical activity (PAEE) energy expenditure were measured using doubly-labeled water and expired gas indirect calorimetry. Results: Total activity was associated with reduced first-phase insulin response in both pregnant (Regression r2 = 0.11; Spearman r = -0.47; p = 0.007) and non-pregnant women (Regression r2 = 0.11 Spearman; r = -0.36; p = 0.002). Relative to non-pregnant women, pregnant women were estimated to have secreted 67% more insulin and had 10% lower fasting glucose than non-pregnant women. Pregnant women spent 13% more time sedentary, 71% less time in moderate-to-vigorous intensity activity, had 44% lower objectively measured total activity, and 12% lower PAEE than non-pregnant women. Correlations did not differ significantly for any comparison between physical activity subcomponents and measures of insulin sensitivity or secretion. Conclusions: Our findings suggest that physical activity conveys similar benefits on glucose homeostasis in pregnant and non-pregnant women, despite differences in subcomponents of physical activity.
- 16 June 2011
- Published by Springer Nature in BMC Pregnancy and Childbirth
- Vol. 11 (1) , 44
Open AccessPhysical activity, sedentary behaviors, and estimated insulin sensitivity and secretion in pregnant and non-pregnant women
Background: Overweight and obesity during pregnancy raise the risk of gestational diabetes and birth complications. Lifestyle factors like physical activity may decrease these risks through beneficial effects on glucose homeostasis. Here we examined physical activity patterns and their relationships with measures of glucose homeostasis in late pregnancy compared to non-pregnant women. Methods: Normal weight and overweight women without diabetes (N = 108; aged 25-35 years) were studied; 35 were pregnant (in gestational weeks 28-32) and 73 were non-pregnant. Insulin sensitivity and β-cell response were estimated from an oral glucose tolerance test. Physical activity was measured during 10-days of free-living using a combined heart rate sensor and accelerometer. Total (TEE), resting (REE), and physical activity (PAEE) energy expenditure were measured using doubly-labeled water and expired gas indirect calorimetry. Results: Total activity was associated with reduced first-phase insulin response in both pregnant (Regression r2 = 0.11; Spearman r = -0.47; p = 0.007) and non-pregnant women (Regression r2 = 0.11 Spearman; r = -0.36; p = 0.002). Relative to non-pregnant women, pregnant women were estimated to have secreted 67% more insulin and had 10% lower fasting glucose than non-pregnant women. Pregnant women spent 13% more time sedentary, 71% less time in moderate-to-vigorous intensity activity, had 44% lower objectively measured total activity, and 12% lower PAEE than non-pregnant women. Correlations did not differ significantly for any comparison between physical activity subcomponents and measures of insulin sensitivity or secretion. Conclusions: Our findings suggest that physical activity conveys similar benefits on glucose homeostasis in pregnant and non-pregnant women, despite differences in subcomponents of physical activity.
- Open Access
- 1 November 2010
- Published by S. Karger AG in Digestion
- Vol. 83 (1-2) , 96-107
Bayesian Hierarchical Methods to Interpret the 13C-Octanoic Acid Breath Test for Gastric Emptying
Background:The 13C-octanoic acid breath test is a convenient method for assessing gastric emptying (GE). Success depends on obtaining a well-characterized time profile of the excretion of label in breath, which may not be the case if GE is delayed. Aims: To use Bayesian techniques in conjunction with hierarchical modelling as a method to increase the success of the modelling process. Methods: Retrospective analysis of 164 individual breath tests using the WinBUGS program. The approach was tested by analysing the complete dataset simultaneously, and also as individual studies. Results: The time required for Bayesian modelling was comparable with that needed for the usual methods. The results obtained were almost identical to those obtained from conventional modelling for well-behaved breath tests, but much more realistic in cases where the experimental data was poor, or when GE was delayed. Conclusions: The use of Bayesian estimation of the parameters of the 13C-octanoic acid breath test is demonstrated. By adopting a hierarchical model, realistic values for the lag phase and half-emptying time were obtained in situations when conventional parameter estimation failed. This is particularly relevant when GE is unexpectedly delayed. We recommend that WinBUGS become the method of choice for analysing breath test data.
- 1 November 2010
- Published by S. Karger AG in Digestion
- Vol. 83 (1-2) , 96-107
Open AccessBayesian Hierarchical Methods to Interpret the 13C-Octanoic Acid Breath Test for Gastric Emptying
Background:The 13C-octanoic acid breath test is a convenient method for assessing gastric emptying (GE). Success depends on obtaining a well-characterized time profile of the excretion of label in breath, which may not be the case if GE is delayed. Aims: To use Bayesian techniques in conjunction with hierarchical modelling as a method to increase the success of the modelling process. Methods: Retrospective analysis of 164 individual breath tests using the WinBUGS program. The approach was tested by analysing the complete dataset simultaneously, and also as individual studies. Results: The time required for Bayesian modelling was comparable with that needed for the usual methods. The results obtained were almost identical to those obtained from conventional modelling for well-behaved breath tests, but much more realistic in cases where the experimental data was poor, or when GE was delayed. Conclusions: The use of Bayesian estimation of the parameters of the 13C-octanoic acid breath test is demonstrated. By adopting a hierarchical model, realistic values for the lag phase and half-emptying time were obtained in situations when conventional parameter estimation failed. This is particularly relevant when GE is unexpectedly delayed. We recommend that WinBUGS become the method of choice for analysing breath test data.
- 1 September 2009
- Published by Wolters Kluwer Health in Current Opinion in Clinical Nutrition and Metabolic Care
- Vol. 12 (5) , 495-500
Recent progress in stable isotope methods for assessing vitamin metabolism
Recent developments in mass spectrometric methodology, in particular the widespread adoption of liquid chromatography/mass spectrometry, have presented investigators with new opportunities to investigate micronutrient absorption and metabolism. This review focuses on recent reports of the use of stable isotope techniques to facilitate research into vitamin uptake and utilization in humans. Stable isotopes are used principally in two ways, as analytical standards in isotope dilution assays and as tracers in studies of physiology. There have been a number of advances in both fields recently for almost all of the vitamins. In particular, the effects of food preparation and meal composition on vitamin bioavailability are being probed more widely than before. A considerable amount of method development has been reported. We now have the opportunity to consolidate our understanding of vitamin metabolism to better inform the dietary recommendations for optimal health.
- 1 September 2009
- Published by Wolters Kluwer Health in Current Opinion in Clinical Nutrition and Metabolic Care
- Vol. 12 (5) , 495-500
Recent progress in stable isotope methods for assessing vitamin metabolism
Recent developments in mass spectrometric methodology, in particular the widespread adoption of liquid chromatography/mass spectrometry, have presented investigators with new opportunities to investigate micronutrient absorption and metabolism. This review focuses on recent reports of the use of stable isotope techniques to facilitate research into vitamin uptake and utilization in humans. Stable isotopes are used principally in two ways, as analytical standards in isotope dilution assays and as tracers in studies of physiology. There have been a number of advances in both fields recently for almost all of the vitamins. In particular, the effects of food preparation and meal composition on vitamin bioavailability are being probed more widely than before. A considerable amount of method development has been reported. We now have the opportunity to consolidate our understanding of vitamin metabolism to better inform the dietary recommendations for optimal health.
- 27 November 2008
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 22 (24) , 4158-4164
A novel derivative for the assessment of urinary and salivary nitrate using gas chromatography/mass spectrometry
Previous gas chromatography/mass spectrometry (GC/MS) methods for determining nitrate in biological samples involve either hazardous chemicals or produce multiple isomers that can be difficult to quantitate. Modification of these methods, by the nitration of mesitylene instead of benzene and in the presence of trifluoroacetic anhydride rather than sulphuric acid, should enable simple isotopic quantitation for use in tracer studies, for example, in the measurement of nitric oxide production. Desiccated urine and saliva samples, in addition to aqueous labelled and unlabelled nitrate standards, were treated with trifluoroacetic anhydride and mesitylene at 70°C for 1 h, cooled, then sequentially washed with deionised water and aqueous sodium bicarbonate. The solution of nitromesitylene in mesitylene was separated, dried and analysed by GC/MS. The full mass spectra exhibited abundant ions at m/z 165 and 166 corresponding to the unlabelled and labelled molecular species of nitromesitylene, respectively. Selected ion monitoring of these masses for a series of gravimetrically prepared standards indicated good agreement with isotopic enrichments in the range 0.0625–5 mole % excess, and at nitrate concentrations within the physiological range of 0.078–2 mmol/L. Derivatised samples were stable with respect to isotopic enrichments and nitrate concentrations at −20°C for up to 21 days and exhibited excellent repeatability. Nitration of mesitylene proved to be a simple and rapid method for the measurement of isotope ratios in aqueous nitrates by GC/MS, which has applications in tracer studies and in concentration determinations by isotope dilution techniques for nitric oxide production. Copyright © 2008 John Wiley & Sons, Ltd.
- 27 November 2008
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 22 (24) , 4158-4164
A novel derivative for the assessment of urinary and salivary nitrate using gas chromatography/mass spectrometry
Previous gas chromatography/mass spectrometry (GC/MS) methods for determining nitrate in biological samples involve either hazardous chemicals or produce multiple isomers that can be difficult to quantitate. Modification of these methods, by the nitration of mesitylene instead of benzene and in the presence of trifluoroacetic anhydride rather than sulphuric acid, should enable simple isotopic quantitation for use in tracer studies, for example, in the measurement of nitric oxide production. Desiccated urine and saliva samples, in addition to aqueous labelled and unlabelled nitrate standards, were treated with trifluoroacetic anhydride and mesitylene at 70°C for 1 h, cooled, then sequentially washed with deionised water and aqueous sodium bicarbonate. The solution of nitromesitylene in mesitylene was separated, dried and analysed by GC/MS. The full mass spectra exhibited abundant ions at m/z 165 and 166 corresponding to the unlabelled and labelled molecular species of nitromesitylene, respectively. Selected ion monitoring of these masses for a series of gravimetrically prepared standards indicated good agreement with isotopic enrichments in the range 0.0625–5 mole % excess, and at nitrate concentrations within the physiological range of 0.078–2 mmol/L. Derivatised samples were stable with respect to isotopic enrichments and nitrate concentrations at −20°C for up to 21 days and exhibited excellent repeatability. Nitration of mesitylene proved to be a simple and rapid method for the measurement of isotope ratios in aqueous nitrates by GC/MS, which has applications in tracer studies and in concentration determinations by isotope dilution techniques for nitric oxide production. Copyright © 2008 John Wiley & Sons, Ltd.
- 14 May 2008
- Published by Wiley in Nutrition Bulletin
- Vol. 33 (2) , 80-90
Doubly labelled water for the measurement of total energy expenditure in man – progress and applications in the last decade
- 14 May 2008
- Published by Wiley in Nutrition Bulletin
- Vol. 33 (2) , 80-90
Doubly labelled water for the measurement of total energy expenditure in man – progress and applications in the last decade
- 17 August 2007
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 21 (18) , 3123-3128
A single glucose derivative suitable for gas chromatography/mass spectrometry and gas chromatography/combustion/isotope ratio mass spectrometry
The incorporation of stable isotopes improves the assessment of glucose metabolism and, with some researchers using two tracers, 2 H‐glucose assessed by gas chromatography/mass spectrometry (GC/MS) and 13 C‐glucose by gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS), a common derivative for both is advantageous. The most commonly used derivatives for GC/MS are inappropriate for GC/C/IRMS as additional functional groups dilute the label. We therefore considered the suitability of six derivatives for both GC/MS and GC/C/IRMS. Glucose alkylboronates were prepared by adding the appropriate alkylboronic acid (butyl‐ or methylboronic acid) in pyridine to desiccated glucose. The derivatisation was completed by reacting this with either (a) acetic anhydride or trifluoroacetic anhydride (acetate derivatives) or (b) bis(trimethylsilyl)trifluoroacetamide BSTFA (TMS derivatives). All six derivatives were assessed using GC/MS and 13 C GC/C/IRMS. Neither TMS derivative exhibited any signal intensity in the molecular ion, although a M‐15 ion showed good agreement between experimental and theoretical data and, whilst still low in intensity, could be suitable for isotope work. Similarly, none of the acetate derivatives showed any intensity at the molecular ion although three key fragmentation series were identified. The most attractive sequence, initiated by the loss of 1,2 cyclic boronate, resulted in the main fragment ion of interest, m/z 240, corresponding to the fluorinated methylboronate derivate. Minimal carbon and hydrogen atoms are added to this derivative making it an excellent choice for stable isotope work, while proving suitable for analysis by both GC/MS and GC/C/IRMS. Copyright © 2007 John Wiley & Sons, Ltd.
- 17 August 2007
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 21 (18) , 3123-3128
A single glucose derivative suitable for gas chromatography/mass spectrometry and gas chromatography/combustion/isotope ratio mass spectrometry
The incorporation of stable isotopes improves the assessment of glucose metabolism and, with some researchers using two tracers, 2 H‐glucose assessed by gas chromatography/mass spectrometry (GC/MS) and 13 C‐glucose by gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS), a common derivative for both is advantageous. The most commonly used derivatives for GC/MS are inappropriate for GC/C/IRMS as additional functional groups dilute the label. We therefore considered the suitability of six derivatives for both GC/MS and GC/C/IRMS. Glucose alkylboronates were prepared by adding the appropriate alkylboronic acid (butyl‐ or methylboronic acid) in pyridine to desiccated glucose. The derivatisation was completed by reacting this with either (a) acetic anhydride or trifluoroacetic anhydride (acetate derivatives) or (b) bis(trimethylsilyl)trifluoroacetamide BSTFA (TMS derivatives). All six derivatives were assessed using GC/MS and 13 C GC/C/IRMS. Neither TMS derivative exhibited any signal intensity in the molecular ion, although a M‐15 ion showed good agreement between experimental and theoretical data and, whilst still low in intensity, could be suitable for isotope work. Similarly, none of the acetate derivatives showed any intensity at the molecular ion although three key fragmentation series were identified. The most attractive sequence, initiated by the loss of 1,2 cyclic boronate, resulted in the main fragment ion of interest, m/z 240, corresponding to the fluorinated methylboronate derivate. Minimal carbon and hydrogen atoms are added to this derivative making it an excellent choice for stable isotope work, while proving suitable for analysis by both GC/MS and GC/C/IRMS. Copyright © 2007 John Wiley & Sons, Ltd.
- 26 January 2006
- Published by IOP Publishing in Physiological Measurement
- Vol. 27 (3) , 279-289
Measurement of gastric emptying by the13C-octanoate breath test—rationalization with scintigraphy
The (13)C-octanoate breath test has not achieved universal acceptance for the measurement of solid phase gastric emptying, largely because the results are not comparable with those from direct methods such as scintigraphy. To convert breath-test data to their scintigraphic equivalent scale corrections are applied which have been obtained from population studies, but there is no guarantee that these are applicable in all cases. We propose an alternative method applicable on an individual basis based upon a simple physiological model which does not require any change to the breath-test protocol. It is demonstrated by comparison with scintigraphy and the octanoate saliva test. Results from an existing dataset of simultaneous breath test, saliva test and scintigraphic determinations of solid phase gastric emptying from nine healthy subjects were re-analysed. The corrected breath tests gave gastric emptying curves which were shown to be not significantly different to those obtained from scintigraphy. The method provides a simple but effective way of generating gastric emptying curves from breath-test data that are directly comparable with direct measurement methods, which is advantageous since it allows the whole of the gastric emptying profile to be generated, not just values for the lag phase and half-emptying times.
- 26 January 2006
- Published by IOP Publishing in Physiological Measurement
- Vol. 27 (3) , 279-289
Measurement of gastric emptying by the13C-octanoate breath test—rationalization with scintigraphy
The (13)C-octanoate breath test has not achieved universal acceptance for the measurement of solid phase gastric emptying, largely because the results are not comparable with those from direct methods such as scintigraphy. To convert breath-test data to their scintigraphic equivalent scale corrections are applied which have been obtained from population studies, but there is no guarantee that these are applicable in all cases. We propose an alternative method applicable on an individual basis based upon a simple physiological model which does not require any change to the breath-test protocol. It is demonstrated by comparison with scintigraphy and the octanoate saliva test. Results from an existing dataset of simultaneous breath test, saliva test and scintigraphic determinations of solid phase gastric emptying from nine healthy subjects were re-analysed. The corrected breath tests gave gastric emptying curves which were shown to be not significantly different to those obtained from scintigraphy. The method provides a simple but effective way of generating gastric emptying curves from breath-test data that are directly comparable with direct measurement methods, which is advantageous since it allows the whole of the gastric emptying profile to be generated, not just values for the lag phase and half-emptying times.
- 9 January 2006
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 20 (3) , 493-498
A stable isotope minimal model protocol with oral glucose administration
A protocol for investigating glucose metabolism whereby stable isotope tracer is given intravenously after an oral glucose challenge is described. Frequent sampling of plasma glucose and insulin allows the tracer disappearance to be interpreted on the basis of established minimal models. We have investigated the glucose effectiveness and insulin sensitivity parameters and their reproducibility in a group of six healthy adults, each studied twice. A mono‐compartmental description of glucose distribution did not provide a physiological description of glucose kinetics, whereas a two‐compartment model gave adequate results in every case. The estimates of glucose effectiveness and insulin sensitivity were 2–3 times higher than those obtained in similar populations using the conventional protocol of the frequently sampled intravenous glucose tolerance test, and this appeared to be related to the kinetics of transport of glucose from accessible to remote pools. The indices of insulin sensitivity obtained in this way were highly reproducible, with a between‐test correlation of 93%. Copyright © 2006 John Wiley & Sons, Ltd.
- 9 January 2006
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 20 (3) , 493-498
A stable isotope minimal model protocol with oral glucose administration
A protocol for investigating glucose metabolism whereby stable isotope tracer is given intravenously after an oral glucose challenge is described. Frequent sampling of plasma glucose and insulin allows the tracer disappearance to be interpreted on the basis of established minimal models. We have investigated the glucose effectiveness and insulin sensitivity parameters and their reproducibility in a group of six healthy adults, each studied twice. A mono‐compartmental description of glucose distribution did not provide a physiological description of glucose kinetics, whereas a two‐compartment model gave adequate results in every case. The estimates of glucose effectiveness and insulin sensitivity were 2–3 times higher than those obtained in similar populations using the conventional protocol of the frequently sampled intravenous glucose tolerance test, and this appeared to be related to the kinetics of transport of glucose from accessible to remote pools. The indices of insulin sensitivity obtained in this way were highly reproducible, with a between‐test correlation of 93%. Copyright © 2006 John Wiley & Sons, Ltd.