Influence of Coronary Plaque Morphology on Local Mechanical States and Associated In-Stent Restenosis
Authors:
Open Access
- 11 March 2026
- journal article
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 148 (4) , 1-32
Abstract
In-stent restenosis (ISR) after percutaneous coronary intervention (PCI) is a multifactorial process. Specific morphological lesion characteristics were observed to contribute to the occurrence of ISR. Local mechanical factors, such as stresses and strains, are known to influence tissue adaptation after stent implantation. However, the influence of morphological features on those local mechanical states and, hence, on the occurrence of ISR remains understudied. This work explores how local mechanical quantities relate to ISR by evaluating the stress distributions in the artery wall during and after stent implantation for morphology-informed lesion examples. We perform computational simulations of the stenting procedure with physics-based patient-specific coronary artery models. Different morphologies are assessed using the spatial plaque composition information from high-resolution coronary computed tomography angiography (CCTA) data. In the sample cases, elevated local tensile stresses were consistently found at sites corresponding to ISR. We found that specific morphological characteristics like circumferential or asymmetric block calcifications result in higher stresses in the surrounding tissue. These findings show that for the observed connection between plaque morphology and ISR, the local mechanical state may represent a relevant link. This study provides a mechanistic, illustrative insight for the examined cases. Future work with larger cohorts and systematic follow-up can establish statistically robust associations.Keywords
All Related Versions
This publication has 74 references indexed in Scilit:
- A consistent mixed-dimensional coupling approach for 1D Cosserat beams and 2D surfaces in 3D spaceComputational Mechanics, 2025
- Influence of plaque characteristics by coronary computed tomography angiography on lesion-specific ischemia: a systematic review and meta-analysisEuropean Radiology, 2025
- Clinical outcomes of percutaneous coronary intervention for severely calcified lesions: comparison between the morphologies of severely calcified coronary lesionsHeart and Vessels, 2024
- Influence of balloon design, plaque material composition, and balloon sizing on acute post angioplasty outcomes: An implicit finite element analysisInternational Journal for Numerical Methods in Biomedical Engineering, 2021
- Influences of plaque eccentricity and composition on the stent–plaque–artery interaction during stent implantationBiomechanics and Modeling in Mechanobiology, 2018
- A homogenized constrained mixture (and mechanical analog) model for growth and remodeling of soft tissueBiomechanics and Modeling in Mechanobiology, 2016
- Patient‐specific finite element analysis of carotid artery stenting: a focus on vessel modelingInternational Journal for Numerical Methods in Biomedical Engineering, 2012
- Gmsh: A 3‐D finite element mesh generator with built‐in pre‐ and post‐processing facilitiesInternational Journal for Numerical Methods in Engineering, 2009
- Finite Element Modeling of Balloon Angioplasty by Considering Overstretch of Remnant Non-diseased Tissues in LesionsComputational Mechanics, 2006
- Mechanics of Biological Tissue2006