Research on Crossing-Pipe Support Structure Defect Detection of EMAT-Excited CSH Wave
Open Access
Abstract
A circumferential shear horizontal (CSH) guide wave-detection method using a periodic permanent magnet electromagnetic acoustic transducer (PPM EMAT) was proposed to solve the defect detection located at the inside of the pipe welded by supporting structures. Firstly, a low-frequency CSH0 mode was selected to establish a three-dimensional equivalent model for the defect detection to cross the pipe support, and the ability of the CSH0 guided wave to propagate through the support and weld structure was analyzed. Then, an experiment was used for the further exploration of the influence of different sizes and types of defects on detection after using the support, as well as the ability of detection mechanism to cross different pipe structures. The results show that both the experiment and the simulation received a good detection signal at 3 mm crack defects, which proves that the method can detect the defects by crossing the welded supporting structure. At the same time, the support structure shows a greater impact on the detection of small defects than the welded structure. The research in this paper can provide ideas for guide wave detection across the support structure in the future.Keywords
Funding Information
- National Natural Science Foundation of China (62071433, 2022YFC3005002, 2016YFF0203003)
- National Key Research and Development Program of China (62071433, 2022YFC3005002, 2016YFF0203003)
This publication has 29 references indexed in Scilit:
- Support Stiffness Monitoring of Cylindrical Structures Using Magnetostrictive Transducers and the Torsional Mode T(0,1)Sensors, 2018
- Smart Sound Processing for Defect Sizing in Pipelines Using EMAT Actuator Based Multi-Frequency Lamb WavesSensors, 2018
- Interaction Between Circumferential Lamb Waves and Lamination in the Midplane of a Metallic PipeJournal of Pressure Vessel Technology, 2017
- Circumferential guided wave EMAT system for pipeline screening using shear horizontal ultrasoundNDT & E International, 2017
- An NDT guided wave technique for the identification of corrosion defects at support locationsNDT & E International, 2015
- Torsional mode magnetostrictive patch transducer array employing a modified planar solenoid array coil for pipe inspectionNDT & E International, 2015
- The reflection of guided waves from simple supports in pipesThe Journal of the Acoustical Society of America, 2011
- Empirical structure for characterizing metal loss defects from radial magnetic flux leakage signalNDT & E International, 2010
- Ultrasonic Circumferential Guided Wave for Pitting-Type Corrosion Imaging at Inaccessible Pipe-Support LocationsJournal of Pressure Vessel Technology, 2008
- Novel Leak Detection System for Pipe Type Cable InstallationsIEEE Transactions on Power Delivery, 2006