Testing the Real-World Accuracy of the Dexcom G6 Pro CGM During the Insulin-Only Bionic Pancreas Pivotal Trial
- 7 November 2023
- journal article
- research article
- Published by SAGE Publications in Diabetes Technology & Therapeutics
- Vol. 25 (11) , 817-821
Abstract
Continuous glucose monitors (CGMs) have transformed the way people with type 1 diabetes can self-monitor glucose levels. Past studies have evaluated the accuracy of CGMs in clinic-based studies, but few have analyzed their accuracy in real-world settings. The Insulin-Only Bionic Pancreas Trial provided the opportunity to assess real-world accuracy of the blinded Dexcom G6 Pro sensor over the first 48–60 h of wear using a blood glucose meter (BGM) as a comparator for 1073 CGM–BGM pairs across 53 participants. The mean absolute relative difference (MARD) was 11.0% over a median period of 50 h (range 47–79 h). The MARD was 13.6% in the first 12 h, 10.5% in hours 12–24, and 10.1% after the first 24 h. These results are comparable with accuracy shown previously with laboratory-based measurements and provide real-world evidence of Dexcom G6 Pro accuracy, which improved after the first 12 h and then remained stable thereafter. Clinical Trial Registry: clinicaltrials.gov ; NCT04200313.Keywords
This publication has 8 references indexed in Scilit:
- Multicenter, Randomized Trial of a Bionic Pancreas in Type 1 DiabetesNew England Journal of Medicine, 2022
- 96-LB: Safety of Glucose Regulation by the Bionic Pancreas without Continuous Glucose Monitoring InputDiabetes, 2022
- Performance of intermittently scanned continuous glucose monitoring systems in people with type 1 diabetes: A pooled analysisDiabetes, Obesity and Metabolism, 2021
- A Three-Way Accuracy Comparison of the Dexcom G5, Abbott Freestyle Libre Pro, and Senseonics Eversense Continuous Glucose Monitoring Devices in a Home-Use Study of Subjects with Type 1 DiabetesDiabetes Technology & Therapeutics, 2020
- Comparative Accuracy Analysis of a Real-time and an Intermittent-Scanning Continuous Glucose Monitoring SystemJournal of Diabetes Science and Technology, 2019
- Continuous Glucose Monitoring Sensors for Diabetes Management: A Review of Technologies and ApplicationsDiabetes & Metabolism Journal, 2019
- Accuracy of a Factory-Calibrated, Real-Time Continuous Glucose Monitoring System During 10 Days of Use in Youth and Adults with DiabetesDiabetes Technology & Therapeutics, 2018
- Accuracy Evaluation of Contour Next Compared with Five Blood Glucose Monitoring Systems Across a Wide Range of Blood Glucose Concentrations Occurring in a Clinical Research SettingDiabetes Technology & Therapeutics, 2015