Evaluation of ultrasound velocity in enucleated equine aqueous humor, lens and vitreous body
Open Access
- 14 October 2014
- journal article
- research article
- Published by Springer Nature in BMC Veterinary Research
- Vol. 10 (1) , 250
Abstract
Sonographic ophthalmic examinations have become increasingly important in veterinary medicine. If the velocity of ultrasound in ocular tissues is known, the A-mode ultrasound method may be used to determine the axial intraocular distances, such as anterior chamber depth, lens thickness, axial length of the vitreous and axial globe length, which are required for intraocular lens (IOL) power calculations. To the authors' knowledge, the velocity of ultrasound in the ocular tissues of the horse was not previously determined. In the present study, 33 lenses, 29 samples of aqueous and 31 of vitreous from 35 healthy equine eyes have been examined. The corresponding ultrasound velocities are reported in dependence of age, temperature, gender and elapsed time after enucleation. The velocity of ultrasound at 36°C in equine aqueous, lens and vitreous are 1529 ±10 m/s, 1654± 29 m/s and 1527 ±16 m/s respectively, and the corresponding conversion factors are 0.998± 0.007, 1.008 ±0.018 and 0.997 ±0.010. A linear increase of the speed of ultrasound with increasing temperature has been determined for aqueous and vitreous. No temperature dependence was found for the speed of ultrasound in the lens. The ultrasound velocity did not significantly differ (95%) on the basis of gender, age or time after enucleation during the first 72 hours after death. Compared to human eyes, the ultrasound velocity in equine lental tissue deviates by one percent. Therefore, axial length measurements obtained with ultrasound velocities for the human eye must be corrected using conversion factors. For the aqueous and vitreous, deviations are below one percent and can be neglected in clinical settings.Keywords
This publication has 22 references indexed in Scilit:
- Evaluation of 30- and 25-diopter intraocular lens implants in equine eyes after surgical extraction of the lensAmerican Journal of Veterinary Research, 2010
- Keratometry, biometry and prediction of intraocular lens power in the equine eyeVeterinary Ophthalmology, 2006
- Evaluation of acoustic wave propagation velocities in the ocular lens and vitreous tissues of pigs, dogs, and rabbitsAmerican Journal of Veterinary Research, 2006
- Relation Between Local Acoustic Parameters and Protein Distribution in Human and Porcine Eye LensesExperimental Eye Research, 1994
- A comparative study of the thermal stability of the vertebrate eye lens: Antarctic ice fish to the desert iguanaExperimental Eye Research, 1990
- Accommodation Used to Determine Ultrasound Velocity in the Human LensOptometry and Vision Science, 1989
- The Emmetropic and the Iseikonic Implant Lens: Computer Calculation of the Refractive Power and its AccuracyOphthalmologica, 1975
- DETERMINATION OF THE VELOCITY OF ULTRASOUND IN THE HUMAN LENS AND VITREOUSActa Ophthalmologica, 1962
- DETERMINATION OF THE VELOCITY OF ULTRASOUND IN OCULAR TISSUES AT DIFFERENT TEMPERATURESActa Ophthalmologica, 1961
- MEASUREMENT OF THE VELOCITY OF SOUND IN SOME PARTS OF THE EYEActa Ophthalmologica, 1958